JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1986; 7:501-508
© 1986 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ohlsson, J
Right arrow Articles by Wranne, B
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ohlsson, J
Right arrow Articles by Wranne, B

Noninvasive assessment of valve area in patients with aortic stenosis

J Ohlsson and B Wranne

A noninvasive method for quantification of aortic orifice area in patients with aortic stenosis is presented and compared with cardiac catheterization data in 24 patients (mean age 67 years). A continuous wave 2 MHz Doppler ultrasound instrument was used to measure the maximal velocity of the aortic jet, and time-averaged pressure drop was obtained by planimetry from the maximal velocity spectral recording using a simplified Bernoulli equation. Left ventricular ejection time was also measured from the spectral recording. Stroke volume was determined with a carbon dioxide-rebreathing method. Noninvasively determined aortic valve areas showed a close correlation with those determined at cardiac catheterization, but mean pressure gradients measured noninvasively were slightly but significantly higher than those measured at catheterization, leading to an underestimation of valve areas with the noninvasive technique, especially when valve areas were large. Neglect of blood flow velocity in the left ventricular outflow tract and recovery of static pressure downstream from the aortic orifice contribute to the difference in the pressure measurements. All patients with a valve area less than 1 cm2 at catheterization, however, also had an area less than 1 cm2 at the noninvasive investigation. This noninvasive approach to the evaluation of the severity of aortic stenosis seems promising for routine clinical use.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
H. Baumgartner, T. Stefenelli, J. Niederberger, H. Schima, and G. Maurer
"overestimation" of catheter gradients by doppler ultrasound in patients with aortic stenosis: a predictable manifestation of pressure recovery
J. Am. Coll. Cardiol., May 1, 1999; 33(6): 1655 - 1661.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. G. Cape, M. Jones, I. Yamada, M. D. VanAuker, and L. M. Valdes-Cruz
Turbulent/Viscous Interactions Control Doppler/Catheter Pressure Discrepancies in Aortic Stenosis: The Role of the Reynolds Number
Circulation, December 1, 1996; 94(11): 2975 - 2981.
[Abstract] [Full Text]


Home page
CirculationHome page
J. Niederberger, H. Schima, G. Maurer, and H. Baumgartner
Importance of Pressure Recovery for the Assessment of Aortic Stenosis by Doppler Ultrasound: Role of Aortic Size, Aortic Valve Area, and Direction of the Stenotic Jet In Vitro
Circulation, October 15, 1996; 94(8): 1934 - 1940.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1986 by the American College of Cardiology Foundation.