cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1986; 7:32-37
© 1986 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hodgson, J.
Right arrow Articles by Williams, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hodgson, J.
Right arrow Articles by Williams, D.

Coronary flow reserve provided by sequential internal mammary artery grafts

JM Hodgson, AK Singh, TM Drew, RS Riley, and DO Williams

Although internal mammary artery bypass grafts have a high patency rate, the adequacy of blood flow through such conduits, particularly if used sequentially, has been questioned. To evaluate this issue, coronary flow reserve was studied in 20 patients after coronary bypass surgery. Nine patients had sequential internal mammary grafts to the diagonal and left anterior descending coronary arteries; five had a single internal mammary graft to the left anterior descending artery and six had sequential saphenous vein grafts. Fifteen additional single vein grafts were also placed in these patients. Coronary flow reserve was measured after contrast-induced hyperemia by a digital subtraction angiographic technique an average of 25 days after surgery. There was no difference in coronary flow reserve between the proximal and distal anastomotic regions in either the sequential internal mammary graft group (2.14 +/- 0.50 versus 2.29 +/- 0.68, n = 8, p = NS) or the sequential vein group (1.77 +/- 0.49 versus 2.08 +/- 0.78, n = 6, p = NS). In addition, the flow reserve provided to either vascular bed of the sequential internal mammary graft was not different from that provided by a single internal mammary graft (1.64 +/- 0.39, n = 5), a single vein graft (1.95 +/- 0.95, n = 15) or nonstenotic native coronary arteries (2.04 +/- 0.87, n = 34). No cases of intracoronary steal were observed. Although some patients had unequal flow reserves between the proximal and distal anastomotic zones, these occurred in the setting of residual coronary stenoses distal to the site of graft insertion or prior myocardial infarction in the grafted distribution.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
P. A. Kurlansky, M. J. Dorman, D. L. Galbut, N. L. Moreno, E. A. Traad, R. G. Carrillo, M. Zucker, L. Sanchez, and G. Ebra
Bilateral Internal Mammary Artery Grafting in Women: A 21-Year Experience
Ann. Thorac. Surg., July 1, 1996; 62(1): 63 - 69.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. A. Spence, W. D. Montgomery, and W. P. Santamore
HIGH FLOW DEMAND ON SMALL ARTERIAL CORONARY BYPASS CONDUITS PROMOTES GRAFT SPASM
J. Thorac. Cardiovasc. Surg., October 1, 1995; 110(4): 952 - 962.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
M. Otaki, R. M. Lust, Y. S. Sun, T. O. Norton, and W. R. Chitwood Jr
Distal Flow Determinants in Canine Myocardium Perfused Through Internal Thoracic Artery Bypass Grafts
Ann. Thorac. Surg., April 1, 1995; 59(4): 829 - 834.
[Abstract] [Full Text]



 
  cardiology careers collections past issues search home