cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1985; 6:1132-1137
© 1985 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Marx, G.
Right arrow Articles by Goldberg, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Marx, G.
Right arrow Articles by Goldberg, S.

Doppler echocardiographic estimation of systolic pulmonary artery pressure in pediatric patients with interventricular communications

GR Marx, HD Allen, and SJ Goldberg

The purpose of this study was to evaluate a noninvasive method for estimation of pulmonary artery pressures in infants and children with interventricular communications. Systolic pulmonary artery pressures measured by cardiac catheterization were compared with those estimated by Doppler echocardiography. Pressure drops were measured by Doppler study (modified Bernoulli equation) and were referenced to systolic systemic arterial pressure measured by sphygmomanometry. All 25 patients in this study had either a ventricular septal defect or a single ventricle. The systolic pulmonary artery pressure measured by cardiac catheterization ranged from 15 to 100 mm Hg (mean +/- SD 44 +/- 26) and that measured by Doppler echocardiography ranged from 5 to 100 mm Hg (mean 43 +/- 26) (p = NS; r = 0.92; SEE = 9.9; slope = 0.92; y intercept = 4.7). Systolic pulmonary artery to aortic pressure ratio measured by cardiac catheterization ranged from 0.2 to 1.0 (mean 0.5 +/- 0.3) and that measured by Doppler echocardiography ranged from 0.1 to 1.0 (mean 0.5 +/- 0.3) (p = NS; r = 0.94; SEE = 0.09; slope = 0.90; y intercept = 0.04). This study demonstrates that Doppler echocardiography can closely approximate systolic pulmonary artery pressure in patients with interventricular communications.


This article has been cited by other articles:


Home page
NeoReviewsHome page
A. Kipps and N. H. Silverman
Historical Perspectives: The Introduction of Ultrasonography in Neonatal Cardiac Diagnosis
NeoReviews, July 1, 2005; 6(7): e315 - e325.
[Full Text] [PDF]


Home page
HeartHome page
A Nygren, J Sunnegårdh, and H Berggren
Preoperative evaluation and surgery in isolated ventricular septal defects: a 21 year perspective
Heart, February 1, 2000; 83(2): 198 - 204.
[Abstract] [Full Text]


Home page
ANGIOLOGYHome page
A. Robida
Underestimation of the Severity of Pulmonary Outflow Tract Obstruction in the First Day of Life--Doppler Echocardiographic Study
Angiology, March 1, 1996; 47(3): 267 - 271.
[Abstract] [PDF]



 
  cardiology careers collections past issues search home