cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1985; 6:682-686
© 1985 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Aylward, P.
Right arrow Articles by Kerber, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Aylward, P.
Right arrow Articles by Kerber, R.

Defibrillator electrode-chest wall coupling agents: influence on transthoracic impedance and shock success

PE Aylward, R Kieso, P Hite, F Charbonnier, and RE Kerber

The purpose of this study was to determine if the difference in transthoracic impedance produced by different coupling agents affects the success of shocks for defibrillation. Three different coupling agents, Harco pads (Hewlett-Packard), Littman pads (3M) and Redux paste (Hewlett-Packard), were assessed in 10 anesthetized dogs in which ventricular fibrillation was induced by electrical stimulation of the right ventricle. Defibrillation was attempted 15 seconds later, using 50, 100 and 150 joules (selected energy). Actual delivered energy, current, impedance and the percent of the shocks that achieved defibrillation were determined for the three coupling agents. Redux paste gave significantly lower impedance and higher current than the two disposable performed coupling pads tested. Despite this, there were no significant differences in shock success among the three coupling agents. Thus, in this experimental model, over a three-fold energy range, disposable coupling pads were as effective as electrode paste for defibrillation despite the slightly higher impedance of the disposable pads.


This article has been cited by other articles:


Home page
HeartHome page
T P Mathew, A Moore, M McIntyre, M T Harbinson, N P S Campbell, A A J Adgey, and G W N Dalzell
Randomised comparison of electrode positions for cardioversion of atrial fibrillation
Heart, June 1, 1999; 81(6): 576 - 579.
[Abstract] [Full Text]


Home page
BMJHome page
Advanced Life Support Working Group of the Europea
The 1998 European Resuscitation Council guidelines for adult advanced life support
BMJ, June 20, 1998; 316(7148): 1863 - 1869.
[Full Text]


Home page
BMJHome page
A. K B Slade, S M. Sopher, A J. Camm, and D. E Ward
Correct technique is important in cardioversion of atrial fibrillation
BMJ, May 18, 1996; 312(7041): 1300a - 1300.
[Full Text]



 
  cardiology careers collections past issues search home