JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1985; 6:565-571
© 1985 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stewart, W.
Right arrow Articles by Weyman, A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Stewart, W.
Right arrow Articles by Weyman, A.

Comparison of high pulse repetition frequency and continuous wave Doppler echocardiography in the assessment of high flow velocity in patients with valvular stenosis and regurgitation

WJ Stewart, KA Galvin, LD Gillam, DE Guyer, and AE Weyman

Continuous wave Doppler echocardiography has proved useful in detecting and quantitating the high velocity flow disturbances that characterize many stenotic and regurgitant valvular lesions. Pulsed Doppler echocardiography, in contrast, is limited in its ability to quantitate the high velocities that are detected. Recently, new pulsed Doppler systems have been developed that employ high pulse repetition frequencies and can theoretically measure higher flow velocities than those measured by the standard pulsed Doppler systems. To determine the ability of high pulse repetition frequency Doppler echocardiography to accurately measure high velocity flow signals in comparison with the continuous wave method, 80 patients undergoing routine echocardiographic examination for the assessment of valvular heart disease were studied using both techniques. A total of 113 high velocity flow disturbances were detected in 68 patients. In 41 instances, the maximal velocities by the two methods were within 0.5 m/s of each other. In 68 of the 113 high velocity lesions, however, the high pulse repetition frequency technique underestimated the peak velocity found with continuous wave Doppler echocardiography by more than 0.5 m/s. Comparison of the peak velocities recorded by the two methods for the total group showed no significant correlation (r = 0.04, p = NS). Comparison of the difference in peak velocities obtained by the two techniques with the maximal continuous wave velocity (n = 94, r = 0.70, slope = 0.71) suggested that the underestimation becomes greater as the peak velocity increases. Fifteen of the study patients with aortic stenosis subsequently underwent catheterization.(ABSTRACT TRUNCATED AT 250 WORDS)





HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1985 by the American College of Cardiology Foundation.