JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1985; 6:539-544
© 1985 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kim, S.
Right arrow Articles by Fisher, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kim, S.
Right arrow Articles by Fisher, J.

Discordance between ambulatory monitoring and programmed stimulation in assessing efficacy of class IA antiarrhythmic agents in patients with ventricular tachycardia

SG Kim, SW Seiden, JA Matos, LE Waspe, and JD Fisher

Concordance between programmed stimulation and 24 hour ambulatory electrocardiographic (Holter) monitoring was studied in 54 patients with sustained ventricular tachycardia during 84 therapeutic trials with class IA antiarrhythmic agents. During baseline studies before treatment, all patients had frequent (greater than or equal to 30/h) ventricular premature complexes on Holter recordings and sustained ventricular tachycardia inducible by one to three extrastimuli. During treatment, programmed stimulation and Holter monitoring were repeated. Efficacy of treatment determined by programmed stimulation (ventricular tachycardia no longer inducible or nonsustained) was compared with three Holter criteria of efficacy: I = 83% or more reduction of ventricular premature complexes and abolition of ventricular tachycardia; II = 50% or more reduction of ventricular premature complexes and 90% or more reduction of couplets and abolition of ventricular tachycardia; III = abolition of ventricular tachycardia in patients with ventricular tachycardia during a baseline Holter recording. Treatments were judged effective by programmed stimulation criteria in only 25% of cases but in 51, 63 and 75% of cases by Holter criterion I, II and III, respectively. Results of programmed stimulation and Holter monitor were discordant (effective by one criterion but ineffective by the other) in 50% of cases using Holter criterion I, in 54% using Holter criterion II and in 61% using Holter criterion III. In the majority of discordant results, treatments appeared efficacious by Holter criteria but ineffective by programmed stimulation criteria, suggesting insensitivity of efficacy by Holter criteria or nonspecificity of induced ventricular tachycardia during treatment, or both.


This article has been cited by other articles:


Home page
CirculationHome page
M. J. Reiter, D. E. Mann, J. E. Reiffel, E. Hahn, and V. Hartz
Significance and Incidence of Concordance of Drug Efficacy Predictions by Holter Monitoring and Electrophysiological Study in the ESVEM Trial
Circulation, April 1, 1995; 91(7): 1988 - 1995.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1985 by the American College of Cardiology Foundation.