JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1985; 6:66-74
© 1985 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gardin, J.
Right arrow Articles by Henry, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gardin, J.
Right arrow Articles by Henry, W.

Superiority of two-dimensional measurement of aortic vessel diameter in Doppler echocardiographic estimates of left ventricular stroke volume

JM Gardin, JM Tobis, A Dabestani, C Smith, U Elkayam, E Castleman, D White, A Allfie, and WL Henry

Attempts to measure left ventricular stroke volume utilizing the Doppler aortic flow method have found varying correlations between invasive thermodilution and non-invasive Doppler methods. Because stroke volume is the product of the Doppler flow velocity integral (that is, the area under the flow velocity curve) and the cross-sectional area of the vessel through which blood flows, both variables are potential sources of error. Previous studies have shown that the Doppler flow velocity integral can be measured with acceptable reproducibility in the ascending aorta. Consequently, in this study an attempt was made to determine empirically the optimal method for measuring aortic diameter and area. The diameter of the ascending aorta was measured utilizing four M-mode and seven two-dimensional echocardiographic conventions. Doppler aortic flow velocity patterns were recorded with a 2.25 MHz M-mode echocardiographic transducer from the suprasternal notch by mapping the ascending aorta until aortic peak flow velocity was recorded. In 19 adult patients undergoing cardiac catheterization for clinical indications, Doppler stroke volume estimates utilizing the various echocardiographic conventions for measuring aortic root diameter and area were compared with simultaneous measurements of stroke volume by the thermodilution technique. The best correlation (r = 0.87) with thermodilution stroke volume was obtained by estimating aortic area from the two-dimensional parasternal long-axis images with the aortic dimension measured distal to the aortic sinuses from the inner to inner wall. The data were related by the equation: Thermodilution stroke volume = (0.73) X (two-dimensional Doppler stroke volume) + 17 cc.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
F. Decailliot, B. Streich, Y. Heurtematte, P. Duvaldestin, D. Cherqui, and F. Stephan
Hemodynamic Effects of Portal Triad Clamping With and Without Pneumoperitoneum: An Echocardiographic Study
Anesth. Analg., March 1, 2005; 100(3): 617 - 622.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
F. STEPHAN, A. NOVARA, B. TOURNIER, J.-M. MAILLET, G. M. LONDON, M. E. SAFAR, and J.-Y. FAGON
Determination of Total Effective Vascular Compliance in Patients with Sepsis Syndrome
Am. J. Respir. Crit. Care Med., January 1, 1997; 157(1): 50 - 56.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1985 by the American College of Cardiology Foundation.