Importance of the duration of inadequate coronary perfusion pressure on resuscitation from cardiac arrest
AB Sanders,
KB Kern,
M Atlas,
S Bragg,
and
GA Ewy
The effect of the duration of inadequate coronary perfusion pressure on resuscitation from cardiac arrest was examined in 32 mongrel dogs with a mean weight of 22 +/- 5 kg. In all dogs, the heart was electrically fibrillated and closed chest compression with assisted ventilation was performed for 15 minutes. At this time, all dogs had an inadequate coronary perfusion pressure (mean 7 +/- 9 mm Hg) and were randomized to a control group (group 1) with continued closed chest compression or to one of the three groups with open chest cardiac massage. These three groups differed only in the duration of continued closed chest compression before initiation of open chest massage (15, 20 and 25 minutes, respectively, in groups 2, 3 and 4). The control group (group 1) had no significant increase in coronary perfusion pressure, and only one of the eight dogs could be resuscitated. The three groups with open chest cardiac massage had a significant increase in coronary perfusion pressure (from 5 +/- 9 to 51 +/- 26 mm Hg, p less than 0.05), but the rate of successful resuscitation depended on the duration of inadequate coronary perfusion pressure before cardiac open chest massage. In group 2, six of eight dogs were resuscitated (p less than 0.05 compared with the control group); in group 3, three of eight dogs were resuscitated and in group 4 none of the eight dogs was resuscitated. The resuscitation rate was significantly (p less than 0.05) greater in group 2 than in group 4. These findings indicate that techniques that improve coronary perfusion pressure during cardiopulmonary resuscitation must be applied before extensive myocardial cellular dysfunction occurs if the probability of successful resuscitation is to be improved.
This article has been cited by other articles:

|
 |

|
 |
 
P. J. Zed, R. B. Abu-Laban, M. Shuster, R. S. Green, R. S. Slavik, and A. H. Travers
Update on cardiopulmonary resuscitation and emergency cardiovascular care guidelines
Am. J. Health Syst. Pharm.,
December 15, 2008;
65(24):
2337 - 2346.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. A. Ewy, M. Zuercher, R. W. Hilwig, A. B. Sanders, R. A. Berg, C. W. Otto, M. M. Hayes, and K. B. Kern
Improved Neurological Outcome With Continuous Chest Compressions Compared With 30:2 Compressions-to-Ventilations Cardiopulmonary Resuscitation in a Realistic Swine Model of Out-of-Hospital Cardiac Arrest
Circulation,
November 27, 2007;
116(22):
2525 - 2530.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. Ristagno, W. Tang, Y.-T. Chang, D. B. Jorgenson, J. K. Russell, L. Huang, T. Wang, S. Sun, and M. H. Weil
The Quality of Chest Compressions During Cardiopulmonary Resuscitation Overrides Importance of Timing of Defibrillation
Chest,
July 1, 2007;
132(1):
70 - 75.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. A. Cooper, J. D. Cooper, and J. M. Cooper
Cardiopulmonary Resuscitation: History, Current Practice, and Future Direction
Circulation,
December 19, 2006;
114(25):
2839 - 2849.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
Part 4: Advanced Life Support
Circulation,
November 29, 2005;
112(22_suppl):
III-25 - III-54.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A.H. Idris, R.A. Berg, J. Bierens, L. Bossaert, C.M. Branche, A. Gabrielli, S.A. Graves, A.J. Handley, R. Hoelle, P.T. Morley, et al.
Recommended Guidelines for Uniform Reporting of Data From Drowning: The "Utstein Style"
Circulation,
November 18, 2003;
108(20):
2565 - 2574.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. Yu, M. H. Weil, W. Tang, S. Sun, K. Klouche, H. Povoas, and J. Bisera
Adverse Outcomes of Interrupted Precordial Compression During Automated Defibrillation
Circulation,
July 16, 2002;
106(3):
368 - 372.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. W. Hilwig, R. A. Berg, K. B. Kern, and G. A. Ewy
Endothelin-1 Vasoconstriction During Swine Cardiopulmonary Resuscitation Improves Coronary Perfusion Pressures but Worsens Postresuscitation Outcome
Circulation,
May 2, 2000;
101(17):
2097 - 2102.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. A. Ewy and J. P. Ornato
Emergency cardiac care: introduction
J. Am. Coll. Cardiol.,
March 15, 2000;
35(4):
825 - 880.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
L. B. Becker, R. A. Berg, P. E. Pepe, A. H. Idris, T. P. Aufderheide, T. A. Barnes, T. A. EdD, S. J. Stratton, and N. C. Chandra
A Reappraisal of Mouth-to-Mouth Ventilation During Bystander-Initiated Cardiopulmonary Resuscitation : A Statement for Healthcare Professionals From the Ventilation Working Group of the Basic Life Support and Pediatric Life Support Subcommittees, American Heart Association
Circulation,
September 16, 1997;
96(6):
2102 - 2112.
[Full Text]
|
 |
|

|
 |

|
 |
 
A. H. Idris, L. B. Becker, J. P. Ornato, J. R. Hedges, N. G. Bircher, N. C. Chandra, R. O. Cummins, W. Dick, U. Ebmeyer, H. R. Halperin, et al.
Utstein-Style Guidelines for Uniform Reporting of Laboratory CPR Research: A Statement for Healthcare Professionals From a Task Force of the American Heart Association, the American College of Emergency Physicians, the American College of Cardiology, the European Resuscitation Council, the Heart and Stroke Foundation of Canada, the Institute of Critical Care Medicine, the Safar Center for Resuscitation Research, and the Society for Academic Emergency Medicine
Circulation,
November 1, 1996;
94(9):
2324 - 2336.
[Full Text]
|
 |
|

|
 |

|
 |
 
Adult Advanced Cardiac Life Support
JAMA,
October 28, 1992;
268(16):
2199 - 2241.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
A. B. Sanders, K. B. Kern, C. W. Otto, M. M. Milander, and G. A. Ewy
End-Tidal Carbon Dioxide Monitoring During Cardiopulmonary Resuscitation: A Prognostic Indicator for Survival
JAMA,
September 8, 1989;
262(10):
1347 - 1351.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
K. Maiese and J. J. Caronna
Coma Following Cardiac Arrest: A Review of the Clinical Features, Management, and Prognosis
J Intensive Care Med,
May 1, 1988;
3(3):
153 - 163.
[Abstract]
[PDF]
|
 |
|
|