JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1985; 5:1395-1402
© 1985 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Webb, C.
Right arrow Articles by Horowitz, L.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Webb, C.
Right arrow Articles by Horowitz, L.

Improved method for evaluating ventriculoatrial conduction before implantation of atrial-sensing dual chamber pacemakers

CR Webb, Spielman SR, AM Greenspan, LA Yacone, and LN Horowitz

Pacemaker-mediated tachycardia may occur when a spontaneous ventricular premature depolarization is retrogradely conducted to the atrium with a ventriculoatrial (VA) interval that exceeds the atrial refractory period of an atrial-sensing dual chamber pacemaker. Previous methods for evaluating VA conduction have failed to predict clinical occurrences of pacemaker-mediated tachycardia. In this study, maximal VA intervals after ventricular extrastimuli during atrial or atrioventricular (AV) sequential pacing were compared with intervals measured by the standard method of ventricular pacing. VA intervals were 201 +/- 53 ms during ventricular pacing and 224 +/- 52 ms after ventricular extrastimuli during atrial pacing (p = NS). VA intervals were 305 +/- 77 ms after ventricular extrastimuli during AV sequential pacing and were longer than VA intervals during ventricular pacing (p less than 0.001) or after ventricular extrastimuli during atrial pacing (p less than 0.01). Thus, the ventricular extrastimulus technique during AV sequential pacing reveals substantially longer VA intervals than does ventricular pacing and explains why pacemaker-mediated tachycardia might occur when pacemaker atrial refractory periods are designed or programmed according to VA intervals measured only during ventricular pacing.


This article has been cited by other articles:


Home page
EuropaceHome page
G. Z. Duray, C. W. Israel, F. T. Wegener, and S. H. Hohnloser
Tachycardia after pacemaker implantation in a patient with complete atrioventricular block
Europace, October 1, 2007; 9(10): 900 - 903.
[Abstract] [Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1985 by the American College of Cardiology Foundation.