JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1985; 5:1087-1093
© 1985 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gradman, A.
Right arrow Articles by Van Zetta, A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Gradman, A.
Right arrow Articles by Van Zetta, A.

Ambulatory electrocardiographic correlates of ventricular inducibility during programmed electrical stimulation

AH Gradman, WP Batsford, EC Rieur, L Leon, and AM Van Zetta

To determine the relation between spontaneous and induced ventricular arrhythmias, ambulatory electrocardiographic (Holter) monitoring and programmed electrical stimulation were performed in 48 adult patients with suspected life-threatening ventricular arrhythmias. Nine had no inducible arrhythmia, 11 demonstrated 1 to 2 beats of intraventricular reentry, 19 exhibited non-sustained ventricular tachycardia and 9 exhibited sustained ventricular tachycardia during electrophysiologic studies. Patients without arrhythmia inducibility had a high incidence of multiformity (56%) and bigeminy (44%), but a low incidence of either couplets (11%) or spontaneous ventricular tachycardia (11%) on Holter monitoring. An increasing incidence of all "complex" ectopic features was found with increasing degrees of ventricular inducibility. In patients with inducible sustained ventricular tachycardia, multiformity was present in 100%, bigeminy and couplets in 89% and spontaneous ventricular tachycardia in 78%. Premature ventricular complex frequency, couplet frequency and the repetition index (the ratio of couplets to premature ventricular complexes) were also found to be directly correlated with the degree of ventricular inducibility. Three quantitative arrhythmia variables were identified which predicted ventricular tachycardia inducibility. Seven (78%) of 9 patients with a mean premature ventricular complex frequency of 100 or more/1,000 normal beats, 11 (85%) of 13 with a mean couplet frequency of 1 or more/1,000 normal beats and 19 (83%) of 23 with a mean repetition index value of 15 or more/1,000 premature ventricular complexes proved to have inducible ventricular tachycardia.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
J Intensive Care MedHome page
P. C. Nalos, M. R. Myers, E. S. Gang, T. Peter, and W. J. Mandel
Analytic Reviews: Electrophysiologic Testing in the Intensive Care Unit
J Intensive Care Med, September 1, 1987; 2(5): 241 - 259.
[Abstract] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1985 by the American College of Cardiology Foundation.