JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 2007; 49:784-789, doi:10.1016/j.jacc.2006.11.021 (Published online 6 February 2007).
© 2007 by the American College of Cardiology Foundation
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
j.jacc.2006.11.021v1
49/7/784    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rozenman, Y.
Right arrow Articles by Parikh, K. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rozenman, Y.
Right arrow Articles by Parikh, K. H.

CLINICAL RESEARCH: HEART FAILURE

Wireless Acoustic Communication With a Miniature Pressure Sensor in the Pulmonary Artery for Disease Surveillance and Therapy of Patients With Congestive Heart Failure

Yoseph Rozenman, MD, FACC*,{dagger},1,*, Robert S. Schwartz, MD, FACC{ddagger},2, Hetal Shah, MPharm§ and Keyur H. Parikh, MD, FACC§

* The Heart Institute, E. Wolfson Medical Center (affiliated with the Sackler Faculty of Medicine Tel-Aviv University), Holon, Israel
{dagger} Remon Medical Technologies, Caesarea, Israel
{ddagger} Minneapolis Heart Institute and Foundation, Minneapolis, Minnesota
§ The Heart Care Clinic, Ahmedabad, India.

Manuscript received May 22, 2006; revised manuscript received October 3, 2006, accepted October 9, 2006.

* Reprint requests and correspondence: Dr. Yoseph Rozenman, Cardiology Department, The E. Wolfson Medical Center, P.O. Box 5, Holon, Israel, 58100. (Email: rozenman{at}wolfson.health.gov.il).

OBJECTIVES: The purpose of this study was to examine the feasibility of repeated pulmonary artery (PA) pressure determinations using a newly developed acoustic wireless implanted communication system.

BACKGROUND: Congestive heart failure management strategies based on monitored intracardiac hemodynamics in patients receiving the best-available therapy may improve outcome. Although electromagnetic communication requires a large antenna for sufficient energy transfer, acoustic energy readily penetrates deep into the body, uses little energy, and uses small internal transducers for bidirectional operation.

METHODS: A miniature device was developed and implanted using right heart catheterization. The ability to obtain PA pressure from the implant using wireless acoustic communication was examined in 8 pigs and 10 patients with congestive heart failure. Macroscopic and histopathologic examinations were performed at 6 months after implantation. The accuracy of PA pressure measurement was determined by comparison with simultaneous pressures from a Millar catheter.

RESULTS: The device was successfully implanted in the PA using right heart catheterization. There were no implantation or later device-related complications. Pulmonary artery pressure tracings were repeatedly obtained from all implants. Normal reactions to intravascular implant were observed macroscopically and in histologic sections. Standard deviations of the difference between implant and Millar PA diastolic pressure were 1.45 and 1.2 mm Hg (animals and humans, respectively). Data were useful for patient management.

CONCLUSIONS: This pilot study demonstrates, for the first time, that acoustic wireless communication with a miniature implanted sensor is feasible and provides repeated PA pressure measurement. This feat makes possible multiple novel applications for monitoring and therapeutic interventions based on measurements from deeply implanted devices.

Abbreviations and Acronyms
  CHF = congestive heart failure
  PA = pulmonary artery




This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
H. E. Verdejo, P. F. Castro, R. Concepcion, M. A. Ferrada, M. A. Alfaro, M. E. Alcaino, C. C. Deck, and R. C. Bourge
Comparison of a Radiofrequency-Based Wireless Pressure Sensor to Swan-Ganz Catheter and Echocardiography for Ambulatory Assessment of Pulmonary Artery Pressure in Heart Failure
J. Am. Coll. Cardiol., December 18, 2007; 50(25): 2375 - 2382.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W.H. W. Tang and G. S. Francis
The Year in Heart Failure
J. Am. Coll. Cardiol., December 11, 2007; 50(24): 2344 - 2351.
[Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 2007 by the American College of Cardiology Foundation.