|
|
||||||||||
|
J Am Coll Cardiol, 2006; 47:40-47, doi:10.1016/j.jacc.2005.09.076 © 2006 by the American College of Cardiology Foundation |
,a
,a,*
* Division of Cardiology, Department of Medicine, The Johns Hopkins University School of Medicine, Baltimore, Maryland
Division of Cardiology, Department of Radiology, The Johns Hopkins University School of Medicine, Baltimore, Maryland
Department of Cardiology, Heart Institute (InCor-DF), Zerbini Foundation, Brasilia, DF, Brazil
Manuscript received June 16, 2005; revised manuscript received September 13, 2005, accepted September 26, 2005.
* Reprint requests and correspondence: Dr. João A. C. Lima, 600 N. Wolfe Street, Blalock 524, The Johns Hopkins Hospital, Baltimore, Maryland 21287-0409 (Email: jlima{at}jhmi.edu).
Multidetector row computed tomography angiography (MDCTA) is seen as a potential alternative to current imaging methods for the assessment of vessel anatomy and atherosclerotic plaque composition/morphology in a great variety of arterial beds. Recent advances represented by the increase in gantry speed to <500 ms per rotation and in the number of detector rows from 4 to 64, in addition to the decrease in slice thickness to submillimetric levels, brought significant improvement in diagnostic accuracy by coronary MDCTA. In general, it has a good correlation with both intravascular ultrasound (IVUS) and histopathology for discrimination between soft, intermediate, and calcified plaques. Plaque area and volume tend to be underestimated by 12-detector row MDCTA and overestimated by 16-detector row MDCTA, but the number of patients studied so far is relatively small. However, it seems that 64-detector row MDCTA can measure plaque area and volume with greater accuracy. Plaque remodeling is overestimated in small vessels by 12-detector row MDCTA, whereas 16- and 64-detector row MDCTA show a good correlation with IVUS. Although still under development, the potential of MDCTA to characterize atherosclerotic plaque composition as well as to precisely determine plaque area, volume, and remodeling in the future is quite promising.
| |||||||||
This article has been cited by other articles:
![]() |
S. Motoyama, H. Anno, M. Sarai, T. Sato, Y. Sanda, Y. Ozaki, T. Mochizuki, K. Katada, and H. Hishida Noninvasive Coronary Angiography With a Prototype 256-Row Area Detector Computed Tomography System Comparison With Conventional Invasive Coronary Angiography. J. Am. Coll. Cardiol., February 19, 2008; 51(7): 773 - 775. [Full Text] [PDF] |
||||
![]() |
S. Motoyama, T. Kondo, M. Sarai, A. Sugiura, H. Harigaya, T. Sato, K. Inoue, M. Okumura, J. Ishii, H. Anno, et al. Multislice Computed Tomographic Characteristics of Coronary Lesions in Acute Coronary Syndromes J. Am. Coll. Cardiol., July 24, 2007; 50(4): 319 - 326. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. Jones, T. Athanasiou, N. Dunne, J. Kirby, S. Attaran, A. Chow, S. Purkayastha, and A. Darzi Multi-slice computed tomography in coronary artery disease. Eur. J. Cardiothorac. Surg., September 1, 2006; 30(3): 443 - 450. [Abstract] [Full Text] [PDF] |
||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |