JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 2005; 45:1672-1675, doi:10.1016/j.jacc.2005.02.037
© 2005 by the American College of Cardiology Foundation
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (14)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lin, G.
Right arrow Articles by Hayes, D. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lin, G.
Right arrow Articles by Hayes, D. L.

CLINICAL RESEARCH: HEART RHYTHM DISORDER

Severe Symptomatic Tricuspid Valve Regurgitation Due to Permanent Pacemaker or Implantable Cardioverter-Defibrillator Leads

Grace Lin, MD*, Rick A. Nishimura, MD, FACC*,*, Heidi M. Connolly, MD, FACC*, Joseph A. Dearani, MD{dagger}, Thoralf M. Sundt, III, MD{dagger} and David L. Hayes, MD, FACC*

* Division of Cardiovascular Disease, Mayo Clinic, Rochester, Minnesota
{dagger} Division of Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota.

Manuscript received July 28, 2004; revised manuscript received December 24, 2004, accepted February 1, 2005.

* Reprint requests and correspondence: Dr. Rick A. Nishimura, Mayo Clinic, Gonda 5-468 East, 200 First Street SW, Rochester, Minnesota 55905. (Email: nishimura.rick{at}mayo.edu).

OBJECTIVES: We report a series of patients with severe tricuspid valve regurgitation due to a permanent pacemaker (PPM) or implantable cardioverter-defibrillator (ICD) lead.

BACKGROUND: Severe tricuspid regurgitation caused by a PPM or ICD lead is an under-recognized but treatable etiology of severe right heart failure.

METHODS: We reviewed the records of 41 patients who underwent tricuspid valve operation for severe tricuspid regurgitation caused by previously placed PPM or ICD leads.

RESULTS: During surgery, severe tricuspid regurgitation was found to be caused by the PPM or ICD leads in all 41 patients. There was a perforation of the tricuspid valve leaflet by the PPM or ICD lead in 7 patients, lead entanglement in the tricuspid valve occurred in 4 patients, lead impingement of the tricuspid valve leaflets occurred in 16 patients, and lead adherence to the tricuspid valve occurred in 14 patients. The septal leaflet was most often perforated (6 of 7). In the preoperative evaluation, valve malfunction due to the PPM or ICD lead was diagnosed preoperatively in only 5 of 41 (12%) patients by transthoracic echocardiography. All patients underwent successful tricuspid valve operation (22 tricuspid valve replacement), with one perioperative death occurring. During follow-up (range, 1 to 99 months), there was one patient who died from left-sided heart failure and three patients died of other causes. The remaining patients showed improvement in signs and symptoms of heart failure.

CONCLUSIONS: Damage to the tricuspid valve by PPM or ICD leads may result in severe symptomatic tricuspid regurgitation and may not be overtly visualized by echocardiography. This etiology should be considered when evaluating patients with severe right heart failure after PPM or ICD implantation.

Abbreviations and Acronyms
  ICD = implantable cardioverter-defibrillator
  PPM = permanent pacemaker




This article has been cited by other articles:


Home page
Eur Heart JHome page
S. Sen-Chowdhry and W. J. McKenna
Non-invasive risk stratification in hypertrophic cardiomyopathy: don't throw out the baby with the bathwater
Eur. Heart J., July 1, 2008; 29(13): 1600 - 1602.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
H. Murayama, M. Maeda, H. Sakurai, A. Usui, and Y. Ueda
Predictors affecting durability of epicardial pacemaker leads in pediatric patients.
J. Thorac. Cardiovasc. Surg., February 1, 2008; 135(2): 361 - 366.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
M. Enriquez-Sarano, V. T. Nkomo, and H. Michelena
Principles and Practice of Echocardiography in Cardiac Surgery
Card. Surg. Adult, January 1, 2008; 3(2008): 315 - 348.
[Full Text]


Home page
Eur J EchocardiogrHome page
A. Loupy, D. Messika-Zeitoun, A. Cachier, D. Himbert, E. Brochet, B. Lung, and A. Vahanian
An unusual cause of pacemaker-induced severe tricuspid regurgitation
Eur J Echocardiogr, January 1, 2008; 9(1): 201 - 203.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
R. A. Nishimura and S. R. Ommen
Hypertrophic Cardiomyopathy, Sudden Death, and Implantable Cardiac Defibrillators: How Low the Bar?
JAMA, July 25, 2007; 298(4): 452 - 454.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. H. Rahimtoola
The Year in Valvular Heart Disease
J. Am. Coll. Cardiol., January 17, 2006; 47(2): 427 - 439.
[Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 2005 by the American College of Cardiology Foundation.