JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 2003; 42:576-582, doi:10.1016/S0735-1097(03)00716-2
© 2003 by the American College of Cardiology Foundation
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wu, M. C.
Right arrow Articles by Dae, M. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wu, M. C.
Right arrow Articles by Dae, M. W.

CLINICAL STUDY

Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice

Max C. Wu, PhD*, Dong-Wei Gao, MD*, Richard E. Sievers, BS{dagger}, Randall J. Lee, MD, PhD{dagger}{ddagger}, Bruce H. Hasegawa, PhD* and Michael W. Dae, MD*{ddagger},*

* Department of Radiology, San Francisco, California, USA
{dagger} Department of Medicine, San Francisco, California, USA
{ddagger} Cardiovascular Research Institute, University of California San Francisco, San Francisco, California, USA

Manuscript received January 4, 2003; revised manuscript received April 4, 2003, accepted April 17, 2003.

* Reprint requests and correspondence: Dr. Michael W. Dae, UCSF Nuclear Medicine, 505 Parnassus Avenue, L-340, San Francisco, California 94143-0252, USA.
michael.dae{at}radiology.ucsf.edu

OBJECTIVES: Although transgenic mice have emerged as powerful experimental models of cardiovascular disease, methods for in vivo phenotypic assessment and characterization remain limited, motivating the development of new instruments for biologic measurement.

BACKGROUND: We have developed a single-photon emission computed tomography system with a pinhole collimator (pinhole SPECT) for high-resolution cardiovascular imaging of mice. In this study, we describe a protocol for myocardial perfusion imaging of mice using technetium-99m (99mTc)-sestamibi and demonstrate the feasibility for measurement of perfusion defect size from pinhole SPECT images.

METHODS: Mice were anesthetized and injected with 370 MBq (10 mCi) of 99mTc-sestamibi. Tomographic projection images were acquired by rotating each mouse in a vertical axis in front of a stationary clinical scintillation camera equipped with a pinhole collimator. BALB/c mice (n = 15) were imaged after the permanent ligation of the left anterior descending coronary artery. The resulting defect size was measured from circumferential profiles of short-axis images. After imaging, the hearts were excised and sectioned to obtain ultra-high resolution digital autoradiographs of 99mTc-sestamibi, from which the actual infarct size was determined.

RESULTS: Reconstructed image quality was equivalent to that obtained for clinical myocardial perfusion imaging. Linear regression analysis produced a correlation coefficient of 0.83 (p < 0.001) between the measured and actual values of the defect size.

CONCLUSIONS: These results demonstrate that myocardial perfusion can be characterized qualitatively and quantitatively in mice using pinhole SPECT.

Abbreviations and Acronyms
  CCK
  cholecystokinin
  MRI
  magnetic resonance imaging
  PET
  positron emission tomography
  ROI
  region of interest
  SPECT
  single-photon emission computed tomography
  99mTc
  technetium-99m




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
H. Thibault, L. Gomez, E. Donal, G. Pontier, M. Scherrer-Crosbie, M. Ovize, and G. Derumeaux
Acute myocardial infarction in mice: assessment of transmurality by strain rate imaging
Am J Physiol Heart Circ Physiol, July 1, 2007; 293(1): H496 - H502.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. Zhou, P. D. Acton, and V. A. Ferrari
Imaging Stem Cells Implanted in Infarcted Myocardium
J. Am. Coll. Cardiol., November 21, 2006; 48(10): 2094 - 2106.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
L. Stegger, A.-N. Hoffmeier, K. P. Schafers, S. Hermann, O. Schober, M. A. Schafers, and G. Theilmeier
Accurate Noninvasive Measurement of Infarct Size in Mice with High-Resolution PET
J. Nucl. Med., November 1, 2006; 47(11): 1837 - 1844.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. Wikstrom, J. Gronros, G. Bergstrom, and L.-m. Gan
Functional and Morphologic Imaging of Coronary Atherosclerosis in Living Mice Using High-Resolution Color Doppler Echocardiography and Ultrasound Biomicroscopy
J. Am. Coll. Cardiol., August 16, 2005; 46(4): 720 - 727.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. Constantinesco, P. Choquet, L. Monassier, V. Israel-Jost, and L. Mertz
Assessment of Left Ventricular Perfusion, Volumes, and Motion in Mice Using Pinhole Gated SPECT
J. Nucl. Med., June 1, 2005; 46(6): 1005 - 1011.
[Abstract] [Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 2003 by the American College of Cardiology Foundation.