J Am Coll Cardiol, 2003; 41:1087-1095, doi:10.1016/S0735-1097(03)00084-6
© 2003 by the American College of Cardiology Foundation
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meyns, B.
Right arrow Articles by Flameng, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Meyns, B.
Right arrow Articles by Flameng, W.

CLINICAL STUDY

Left ventricular support by Catheter-Mountedaxial flow pump reduces infarct size

Bart Meyns, MD, PhD*,*, Jarek Stolinski, MD*, Veerle Leunens*, Erik Verbeken, MD, PhD* and Willem Flameng, MD, PhD*

* Center for Experimental Surgery and Anesthesiology, Cardiovascular Research Unit, Catholic University of Leuven (KUL), Leuven, Belgium

Manuscript received March 18, 2002; revised manuscript received September 5, 2002, accepted November 19, 2002.

* Reprint requests and correspondence: Dr. Bart Meyns, Department of Cardiac Surgery, Herestraat 49, 3000 Leuven, Belgium.
Bart.Meyns{at}uz.kuleuven.ac.be

OBJECTIVES: We sought to investigate the effect of a catheter-mounted microaxial blood pump (Impella, Aachen, Germany) on myocardial infarct size.

BACKGROUND: The small rotary blood pump Impella provides unloading of the left ventricle and is introducible via the femoral artery.

METHODS: Myocardial infarction was induced by occlusion of major branches of the left anterior descending coronary artery for 60 min followed by 120 min of reperfusion in 26 sheep. The animals were allocated to four groups: group 1 had no support; group 2 was fully supported with the pump during ischemia and reperfusion; group 3 was supported during reperfusion only; and group 4 was partially supported during reperfusion. Infarct size, hemodynamics, myocardial oxygen consumption, lactate extraction, and myocardial flow were analyzed.

RESULTS: Infarct size was significantly reduced in the pump-supported animals (percent area at risk in group 1: 67.2 ± 4.6%; group 2: 18.1 ± 10%; group 3: 41.6 ± 5.8%; group 4: 54 ± 8%; p = 0.00001). The pump produced 4.1 ± 0.1 l/min at full support and 2.4 ± 0.1 l/min at partial support. The pump significantly increased the diastolic and mean blood pressures (groups 2, 3, and 4) and significantly decreased the left ventricular end-diastolic pressure (groups 2 and 3). During ischemia, myocardial flow was not influenced by pump support. At reperfusion, the fully supported group had significantly higher myocardial flow. Pump support reduced myocardial oxygen consumption significantly, and this reduction correlates strongly with the reduction in infarct size (r = 0.9).

CONCLUSIONS: Support by a microaxial blood pump reduces myocardial oxygen consumption during ischemia and reperfusion and leads to a reduction of infarct size. This reduction in infarct size correlates with the degree of unloading during reperfusion.

Abbreviations and Acronyms
  BP = blood pressure
  CBF = coronary blood flow
  Hb = hemoglobin
  LER = lactate extraction ratio
  LV = left ventricle/ventricular
  MI = myocardial infarction/infarct
  RV = right ventricle/ventricular
  TTC = triphenyltetrazolium chloride




This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. Tamareille, H. Achour, J. Amirian, P. Felli, R. J. Bick, B. Poindexter, Y. J. Geng, W. H. Barry, and R. W. Smalling
Left ventricular unloading before reperfusion reduces endothelin-1 release and calcium overload in porcine myocardial infarction.
J. Thorac. Cardiovasc. Surg., August 1, 2008; 136(2): 343 - 351.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
H. Thiele, R. W. Smalling, and G. C. Schuler
Percutaneous left ventricular assist devices in acute myocardial infarction complicated by cardiogenic shock
Eur. Heart J., September 1, 2007; 28(17): 2057 - 2063.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
H. Thiele, P. Sick, E. Boudriot, K.-W. Diederich, R. Hambrecht, J. Niebauer, and G. Schuler
Randomized comparison of intra-aortic balloon support with a percutaneous left ventricular assist device in patients with revascularized acute myocardial infarction complicated by cardiogenic shock
Eur. Heart J., July 1, 2005; 26(13): 1276 - 1283.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. Schmitz-Rode, J. Graf, J. G. Pfeffer, F. Buss, C. Brucker, and R. W. Gunther
An Expandable Percutaneous Catheter Pump for Left Ventricular Support: Proof of Concept
J. Am. Coll. Cardiol., June 7, 2005; 45(11): 1856 - 1861.
[Abstract] [Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK