CLINICAL STUDY
Influence of wall stress and left ventricular geometry on the accuracy of dobutamine stress echocardiography
Satoshi Yuda, MD, PhD*,
Vincent Khoury, MB, BS* and
Thomas H. Marwick, MB, BS, PhD, FACC*,*
* University of Queensland, Brisbane, Australia
Manuscript received February 5, 2002;
revised manuscript received April 16, 2002,
accepted May 29, 2002.
* Reprint requests and correspondence: Dr. Thomas H. Marwick, University of Queensland, Department of Medicine, Princess Alexandra Hospital, Ipswich Road, Brisbane, QLD 4102, Australia. tmarwick{at}medicine.pa.uq.edu.au
OBJECTIVES: The goal of this study was to determine whether wall stress at rest and during stress could explain the influence of left ventricular (LV) morphology on the accuracy of dobutamine stress echocardiography (DSE).
BACKGROUND: The sensitivity of DSE appears to be reduced in patients with concentric remodeling, but the cause of this finding is unclear.
METHODS: We studied 161 patients without resting wall motion abnormalities who underwent DSE and coronary angiography. Patients were classified into four groups according to relative wall thickness (normal <0.45) and LV mass (normal 131 g/m2 in men and 100 g/m2 in women): normal geometry, concentric remodeling, concentric hypertrophy, and eccentric hypertrophy. Significant coronary artery disease was defined as 50% stenosis. Circumferential (cESS) and meridional end-systolic wall stress (mESS) were calculated at rest and peak DSE.
RESULTS: Both false-negative and false-positive results for DSE were present in 35 patients (22%). The accuracy of DSE in patients with concentric remodeling (61%) was lower than that in patients with normal geometry (85%, p < 0.05) or concentric hypertrophy (86%, p < 0.05), but the accuracy with eccentric hypertrophy (64%, p < 0.05) was lower than with concentric hypertrophy. Patients in lowest quartile of cESS and mESS at peak had significantly lower sensitivity and accuracy than those in the highest quartile. A reduced cESS at peak (p = 0.012), presence of concentric remodeling (p = 0.044), and eccentric hypertrophy (p = 0.012) were significant predictors of both false-negative and false-positive results for DSE.
CONCLUSIONS: The accuracy of DSE is influenced by the LV geometric pattern and peak wall stress.
|
Abbreviations and Acronyms
| | BP | | blood pressure | | CAD | | coronary artery disease | | cESS | | circumferential end-systolic wall stress | | DSE | | dobutamine stress echocardiography | | HR | | heart rate | | LV | | left ventricle/ventricular | | mESS | | meridional end-systolic wall stress | | RWT | | relative wall thickness |
|
This article has been cited by other articles:

|
 |

|
 |
 
C. Parsai, A. Baltabaeva, L. Anderson, M. Chaparro, B. Bijnens, and G. R. Sutherland
Low-dose dobutamine stress echo to quantify the degree of remodelling after cardiac resynchronization therapy
Eur. Heart J.,
April 2, 2009;
30(8):
950 - 958.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
S. Y. Hayashi, A. Seeberger, B. Lind, J. Nowak, M. M. do Nascimento, B. Lindholm, and L.-A. Brodin
A single session of haemodialysis improves left ventricular synchronicity in patients with end-stage renal disease: a pilot tissue synchronization imaging study
Nephrol. Dial. Transplant.,
November 1, 2008;
23(11):
3622 - 3628.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. V. Dinh, J. Alvergue, J. Sayre, J. S. Child, V. S. Deshpande, G. Laub, and J. P. Finn
Isovolumic Cardiac Contraction on High-Temporal-Resolution Cine MR Images: Study in Heart Failure Patients and Healthy Volunteers
Radiology,
August 1, 2008;
248(2):
458 - 465.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Kozakova, E. Muscelli, A. Flyvbjerg, J. Frystyk, C. Morizzo, C. Palombo, and E. Ferrannini
Adiponectin and Left Ventricular Structure and Function in Healthy Adults
J. Clin. Endocrinol. Metab.,
July 1, 2008;
93(7):
2811 - 2818.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
F. Xie, S. Dodla, E. O'Leary, and T. R. Porter
Detection of subendocardial ischemia in the left anterior descending coronary artery territory with real-time myocardial contrast echocardiography during dobutamine stress echocardiography.
J. Am. Coll. Cardiol. Img.,
May 1, 2008;
1(3):
271 - 278.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. H. Marwick
Assessment of subendocardial function with myocardial contrast echocardiography.
J. Am. Coll. Cardiol. Img.,
May 1, 2008;
1(3):
279 - 281.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. N. Mazzadi, X. Andre-Fouet, N. Costes, P. Croisille, D. Revel, and M. F. Janier
Mechanisms leading to reversible mechanical dysfunction in severe CAD: alternatives to myocardial stunning
Am J Physiol Heart Circ Physiol,
December 1, 2006;
291(6):
H2570 - H2582.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
L. Carrier, R. Knoll, N. Vignier, D. I Keller, P. Bausero, B. Prudhon, R. Isnard, M.-L. Ambroisine, M. Fiszman, J. Ross Jr., et al.
Asymmetric septal hypertrophy in heterozygous cMyBP-C null mice
Cardiovasc Res,
August 1, 2004;
63(2):
293 - 304.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
N. C. Lai, D. M. Roth, M. H. Gao, T. Tang, N. Dalton, Y. Y. Lai, M. Spellman, P. Clopton, and H. K. Hammond
Intracoronary Adenovirus Encoding Adenylyl Cyclase VI Increases Left Ventricular Function in Heart Failure
Circulation,
July 20, 2004;
110(3):
330 - 336.
[Abstract]
[Full Text]
[PDF]
|
 |
|
|