JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1984; 4:561-564
© 1984 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Huhta, J.
Right arrow Articles by Gutgesell, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Huhta, J.
Right arrow Articles by Gutgesell, H.

Patency of the ductus arteriosus in normal neonates: two-dimensional echocardiography versus Doppler assessment

JC Huhta, M Cohen, and HP Gutgesell

Two-dimensional echocardiography using a high resolution, 7.5 ,Jsz transduce was compared with Doppler echocardiography for the assessment of patency of the ductus arteriosus in normal newborn infants. Twenty-eight neonates were studied between 1 and 10 hours (mean 5.5) after birth and both examinations were possible in 27 (96%). Doppler echocardiography under two-dimensional direction indicated ductal patency in all 27 neonates. Doppler sampling in the pulmonary end of the ductus rather than the main pulmonary artery was more sensitive for detecting patency. When two-dimensional echocardiography only was used to predict patency, there was 85% sensitivity. Two-dimensional echocardiography showed no evidence of ductus arteriosus narrowing ion four neonates studied shortly after birth. In 18, the pulmonary portion of the ductus arteriosus appeared narrowed and in 8 of these, the narrowing extended toward the mid-portion of the ductus. In five others, there was only mid-ductus arteriosus narrowing. It is concluded that high resolution two-dimensional echocardiography can be used to assess ductus arteriosus morphology, but is limited in predicting ductal patency near the time of normal physiologic closure. Combined two-dimensional and Doppler echocardiography is a highly sensitive technique for detection of ductal patency when sampling is performed in the pulmonary end of the ductus arteriosus.


This article has been cited by other articles:


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
B.-H. Su, T. Watanabe, M. Shimizu, and M. Yanagisawa
Echocardiographic assessment of patent ductus arteriosus shunt flow pattern in premature infants
Arch. Dis. Child. Fetal Neonatal Ed., July 1, 1997; 77(1): 36F - 40.
[Abstract] [Full Text]