cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1984; 4:493-500
© 1984 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Platia, E.
Right arrow Articles by Reid, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Platia, E.
Right arrow Articles by Reid, P.

Comparison of programmed electrical stimulation and ambulatory electrocardiographic (Holter) monitoring in the management of ventricular tachycardia and ventricular fibrillation

EV Platia and PR Reid

Forty-four patients with primary ventricular fibrillation or recurrent ventricular tachycardia were stabilized on an antiarrhythmic drug regimen before electrophysiologic study and 24 to 72 hours of ambulatory electrocardiographic monitoring were performed. The long-term predictive value of these two tests was then compared retrospectively for a 12 to 32 month (mean 18) follow-up period, during which all patients continued receiving the same antiarrhythmic drug regimen. Electrophysiologic testing induced ventricular tachycardia (greater than or equal to 3 beats) in 26 patients; 23 had a poor clinical outcome (positive predictive value 88%), defined as sudden death or sustained ventricular tachycardia. In 18 patients with a negative electrophysiologic test, only 1 had a poor clinical outcome (negative predictive value 94%). Ambulatory electrocardiographic monitoring accurately predicted outcome in 7 of 10 patients with a positive recording (positive predictive value 70%), defined as three or more consecutive ventricular extrasystoles, and in 17 of 34 patients with negative ambulatory monitor recordings (negative predictive value 50%). The long-term predictive accuracy of the electrophysiologic study was significantly higher than that of the ambulatory electrocardiographic monitor (p less than 0.001). Electrophysiologic studies offer advantages over ambulatory electrocardiographic monitoring in this high risk patient group, providing a high degree of accuracy in predicting the long-term clinical response to antiarrhythmic drugs for at least 18 months.


This article has been cited by other articles:


Home page
CirculationHome page
M. J. Reiter, D. E. Mann, J. E. Reiffel, E. Hahn, and V. Hartz
Significance and Incidence of Concordance of Drug Efficacy Predictions by Holter Monitoring and Electrophysiological Study in the ESVEM Trial
Circulation, April 1, 1995; 91(7): 1988 - 1995.
[Abstract] [Full Text]


Home page
NEJMHome page
J. W. Mason and The Electrophysiologic Study versus Electrocardiog
A Comparison of Electrophysiologic Testing with Holter Monitoring to Predict Antiarrhythmic-Drug Efficacy for Ventricular Tachyarrhythmias
N. Engl. J. Med., August 12, 1993; 329(7): 445 - 451.
[Abstract] [Full Text]


Home page
J Intensive Care MedHome page
P. C. Nalos, M. R. Myers, E. S. Gang, T. Peter, and W. J. Mandel
Analytic Reviews: Electrophysiologic Testing in the Intensive Care Unit
J Intensive Care Med, September 1, 1987; 2(5): 241 - 259.
[Abstract] [PDF]



 
  cardiology careers collections past issues search home