JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1984; 4:454-462
© 1984 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Panidis, I.
Right arrow Articles by Ross, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Panidis, I.
Right arrow Articles by Ross, J

Clinical and echocardiographic evaluation of the St. Jude cardiac valve prosthesis: follow-up of 126 patients

IP Panidis, JF Ren, MN Kotler, GS Mintz, ED Mundth, IP Goel, and J Ross

One hundred twenty-six patients with a St. Jude valve prosthesis were followed up clinically and studied by combined M-mode echocardiography and phonocardiography. Fifty patients underwent aortic valve replacement, 58 underwent mitral valve replacement and 18 underwent a combination of the two. The early postoperative mortality rate was 8% for aortic, 6.9% for mitral and 6% for combined valve replacement. Follow-up ranged from 2 to 46 months (mean +/- SD 28 +/- 9). The late postoperative mortality rate was 5%; in patients who survived, improvement in New York Heart Association functional class occurred in 97%. Major thromboembolic events occurred in two patients and anticoagulation-related complications occurred in three patients. Valve-related complications occurred in 14 patients and included bacterial endocarditis (6 patients), paravalvular leak (5 patients), severe hemolysis (1 patient), thrombosis of valve (1 patient) and possible mechanical valve failure (1 patient). In 7 of these 14 patients, repeat surgery was required and 5 patients survived. Abnormal echocardiographic findings in these seven patients included a shortened aortic closure (A2) to mitral valve opening interval, increased left atrial and left ventricular size and initial diastolic rounding of the St. Jude valve motion in the patient with the thrombosed valve. It is concluded that the St. Jude valve prosthesis is associated with favorable functional results and a low complication rate for a mean follow-up period of 28 months. Combined M-mode echocardiography and phonocardiography may be useful in assessing patients with suspected complications related to the St. Jude cardiac valve.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
Y. Shapira, I. Herz, M. Vaturi, A. Porter, Y. Adler, Y. Birnbaum, B. Strasberg, S. Sclarovsky, and A. Sagie
Thrombolysis is an effective and safe therapy in stuck bileaflet mitral valves in the absence of high-risk thrombi
J. Am. Coll. Cardiol., June 1, 2000; 35(7): 1874 - 1880.
[Abstract] [Full Text] [PDF]


Home page
ANGIOLOGYHome page
B. Chakraborty, S. Quek, Ding Zee Pin, Chee Tek Siong, Tan Ley Kheng, and B. Chakraborty
Evaluation of Normal Hemodynamic Profile of Carbomedics Prosthetic Valves by Doppler Echocardiography
Angiology, December 1, 1997; 48(12): 1055 - 1061.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. W. Akins
Results With Mechanical Cardiac Valvular Prostheses
Ann. Thorac. Surg., December 1, 1995; 60(6): 1836 - 1844.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1984 by the American College of Cardiology Foundation.