JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1984; 4:308-315
© 1984 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Burbank, F.
Right arrow Articles by Bradley, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Burbank, F.
Right arrow Articles by Bradley, B.

Effect of volume and rate of contrast medium injection on intravenous digital subtraction angiographic contrast medium curves

FH Burbank, WR Brody, and BR Bradley

The image quality of temporal (mask mode) intravenous digital subtraction angiography is directly dependent on the shape of arterial time-concentration curves produced by the intravenous injection of contrast medium. Curves that are narrow and tall minimize motion artifact (misregistration) and maximize contrast enhancement (pre- and postcontrast differences). To determine the effects of rate and volume of injection of contrast medium on intravenous digital subtraction angiographic curves, ioxaglate (Hexabrix), a monoacidic ionic dimer, was injected into large mongrel dogs. Quantitative measurements of opacification were made over time in the femoral arteries using a modified General Electric CT/T scanner. Peak opacification was directly proportional to the volume of contrast medium injected. Curve width was not affected by increasing volume of injection. At rates below a critical point, slower injection rates produced progressively shorter and wider arterial time-concentration curves. Above that critical point, increasing the rate of injection did not affect either curve width or curve peak.


This article has been cited by other articles:


Home page
RadiologyHome page
W. G. Kuhle and R. G. Sheiman
Detection of Active Colonic Hemorrhage with Use of Helical CT: Findings in a Swine Model
Radiology, September 1, 2003; 228(3): 743 - 752.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. Fleischmann, G. D. Rubin, A. A. Bankier, and K. Hittmair
Improved Uniformity of Aortic Enhancement with Customized Contrast Medium Injection Protocols at CT Angiography
Radiology, February 1, 2000; 214(2): 363 - 371.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1984 by the American College of Cardiology Foundation.