cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1984; 4:245-252
© 1984 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gallino, A
Right arrow Articles by Maseri, A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gallino, A
Right arrow Articles by Maseri, A

Computer system for analysis of ST segment changes on 24 hour Holter monitor tapes: comparison with other available systems

A Gallino, S Chierchia, G Smith, M Croom, M Morgan, C Marchesi, and A Maseri

The accuracy of a computer system that was developed for the analysis of ST segment changes recorded on Holter ambulatory electrocardiographic monitoring tapes was compared with conventional visual scrutiny, beat by beat analog printouts and a commercial J point trend system. The program calculates and plots multiple electrocardiographically derived variables in a high temporal resolution trend format. Fifty tapes of good recording quality obtained from 19 patients (13 with chronic stable angina and 6 with variant angina) were assessed visually and with the computer system; of these, 20 were analyzed by all four techniques. In the 50 tapes, 629 episodes of diagnostic ST segment changes (all true positive results) were identified by using the computer system. In contrast, only 507 were identified by visual scrutiny; none of these 507 episodes was missed by computer analysis. On the 20 tapes assessed using computer, visual, beat by beat analog and J point trend system analysis, 268, 221, 230 and 178 episodes, respectively, were documented. For the four techniques, false negative and positive results were 0, 47, 38 and 90 and 0, 10, 6 and 24, respectively. The results indicate that, of the systems assessed in this study, the computer program provides the highest accuracy for detection of transient ST segment changes. This is probably accreditable to the compact presentation of multiple electrocardiographically derived variables, allowing a detailed quantitative assessment of 24 hour tapes. It is of particular value for pathophysiologic and pharmacologic studies.


This article has been cited by other articles:


Home page
CirculationHome page
F. Crea and A. Gaspardone
New Look to an Old Symptom: Angina Pectoris
Circulation, November 18, 1997; 96(10): 3766 - 3773.
[Abstract] [Full Text]



 
  cardiology careers collections past issues search home