Advertisement





Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1999; 33:24-32
© 1999 by the American College of Cardiology Foundation
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pires, L. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pires, L. A.

CLINICAL STUDIES

Sudden death in implantable cardioverter-defibrillator recipients: clinical context, arrhythmic events and device responses

Luis A. Pires, MD, FACCa, Michael H. Lehmann, MD, FACCa, Russell T. Steinman, MD, FACCa, John J. Baga, MD, FACCa, Claudio D. Schuger, MD, FACCa and Participating Investigators*

a Arrhythmia Center/Sinai Hospital and Wayne State University School of Medicine, Detroit, Michigan, USA

Manuscript received April 15, 1998; revised manuscript received August 14, 1998, accepted September 17, 1998.

Address for correspondence: Dr. Luis A. Pires, Cardiac Electrophysiology, St. John Hospital Medical Center, 22101 Moross, Detroit, MI 48236

Objectives. We sought to investigate the nature of terminal events and potential contributory clinical and nonclinical (e.g., device-related) factors associated with sudden death (SD) in recipients of an implantable cardioverter-defibrillator (ICD).

Background. The ICD is very effective in terminating ventricular tachycardia (VT) or ventricular fibrillation (VF), but protection against SD is not absolute. Little is known about the nature and potential causes of SD in patients with ICDs.

Methods. We analyzed 25 cases of out-of-hospital SD among patients enrolled in the clinical investigation of the Cadence Tiered-Therapy Defibrillator System.

Results. All patients (24 men and 1 woman, mean age 62 ± 10 years) received epicardial lead systems. The majority (92%) had coronary artery disease and a previous myocardial infarction (MI), with a mean left ventricular ejection fraction 0.25 ± 0.07. At device implantation, the mean defibrillation threshold was 13 ± 5 J. Sudden death occurred 13 ± 11 months later. Twenty patients (80%) had received appropriate ICD therapies before death, and 18 (72%) were receiving ≥1 antiarrhythmic drugs at the time of death. Sudden death was tachyarrhythmia-associated in 16 patients (64%), non-tachyarrhythmia-associated in 7 (28%) and indeterminate in 2 (8%). In the 16 patients with tachyarrhythmia-associated SD, the overall first therapy success rate in tachycardia and fibrillation zones was 60% and 67%, respectively. However, despite protracted therapies (≥2 shocks) in 7 (66%) of 12 patients who received fibrillation therapies, the final tachyarrhythmic episode was ultimately terminated by the ICD in 15 (94%) of the 16 patients, whereas 1 patient died after multiple (initially successful) internal and external shocks for intractable VT/VF during exercise. In 10 patients (40%) one or more, primarily clinical, factors potentially contributory to SD were identified: heart failure (n = 8), angina (n = 2), hypokalemia (n = 1), adverse antiarrhythmic drug treatment (n = 1) and acute MI (n = 1). An additional 10 patients (40%) had experienced an increase in frequency of ICD shocks within 3 months of SD. Appropriate battery voltages and normal circuitry function were found in all devices interrogated and analyzed after death.

Conclusions. In this select group of patients receiving a third-generation ICD, SD was associated with VT or VF events in nearly two-thirds of patients, and death occurred despite ultimately successful, although often protracted, device therapies. These observations, along with evidence of recent worsening clinical status, suggest acute cardiac mechanical dysfunction as a frequent terminal factor. In recipients with ICDs, SD directly attributable to device failure seems to be rare.

Abbreviations and Acronyms
  CHF = congestive heart failure
  DFT = defibrillation threshold
  EHR = extended high rate
  EMD = electromechanical dissociation
  ICD = implantable cardioverter-defibrillator
  LVEF = left ventricular ejection fraction
  MI = myocardial infarction
  SD = sudden death
  VF = ventricular fibrillation
  VT = ventricular tachycardia




This article has been cited by other articles:


Home page
EuropaceHome page
T. W. Baron, T. S. Faber, A. Grom, T. Schwab, M. Brunner, A. Geibel, H. Just, C. Bode, and M. Zehender
Real-time assessment of acute myocardial ischaemia by an intra-thoracic 6-lead ECG: evaluation of a new diagnostic option in the implantable defibrillator
Europace, November 1, 2006; 8(11): 994 - 1001.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
H. V. Huikuri, T. H. Makikallio, M. J. P. Raatikainen, J. Perkiomaki, A. Castellanos, and R. J. Myerburg
Prediction of Sudden Cardiac Death: Appraisal of the Studies and Methods Assessing the Risk of Sudden Arrhythmic Death
Circulation, July 8, 2003; 108(1): 110 - 115.
[Full Text] [PDF]


Home page
CirculationHome page
W. G. Stevenson and L. M. Epstein
Predicting Sudden Death Risk for Heart Failure Patients in the Implantable Cardioverter-Defibrillator Age
Circulation, February 4, 2003; 107(4): 514 - 516.
[Full Text] [PDF]


Home page
CirculationHome page
A. E. Buxton, K. L. Lee, G. E. Hafley, D. G. Wyse, J. D. Fisher, M. H. Lehmann, L. A. Pires, M. R. Gold, D. L. Packer, M. E. Josephson, et al.
Relation of Ejection Fraction and Inducible Ventricular Tachycardia to Mode of Death in Patients With Coronary Artery Disease: An Analysis of Patients Enrolled in the Multicenter Unsustained Tachycardia Trial
Circulation, November 5, 2002; 106(19): 2466 - 2472.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
L. B. Mitchell, E. A. Pineda, J. L. Titus, P. M. Bartosch, and D. G. Benditt
Sudden death in patients with implantable cardioverter defibrillators: The importance of post-shock electromechanical dissociation
J. Am. Coll. Cardiol., April 17, 2002; 39(8): 1323 - 1328.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
G. Gronefeld and S. H Hohnloser
What do implantable cardioverter/defibrillators teach us about the mechanisms of sudden cardiac death?
Cardiovasc Res, May 1, 2001; 50(2): 232 - 241.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
R J P LEWIN, D J FRIZELLE, and G C KAYE
A rehabilitative approach to patients with internal cardioverter-defibrillators
Heart, April 1, 2001; 85(4): 371 - 372.
[Full Text]


Home page
NEJMHome page
B. J. Maron, W.-K. Shen, M. S. Link, A. E. Epstein, A. K. Almquist, J. P. Daubert, G. H. Bardy, S. Favale, R. F. Rea, G. Boriani, et al.
Efficacy of Implantable Cardioverter-Defibrillators for the Prevention of Sudden Death in Patients with Hypertrophic Cardiomyopathy
N. Engl. J. Med., February 10, 2000; 342(6): 365 - 373.
[Abstract] [Full Text] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement