Advertisement





Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1998; 32:746-752
© 1998 by the American College of Cardiology Foundation
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cohen, J. L.
Right arrow Articles by Bruns, D. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cohen, J. L.
Right arrow Articles by Bruns, D. E.

CLINICAL STUDIES

Improved left ventricular endocardial border delineation and opacification with OPTISON (FS069), a new echocardiographic contrast agent

Results of a phase III multicenter trial1

Jerald L. Cohen, MD, FACC*, Jorge Cheirif, MD, FACC{dagger}, Douglas S. Segar, MD, FACC{ddagger}, Linda D. Gillam, MD, FACC§, John S. Gottdiener, MD, FACC||, Eva Hausnerova, MD|| and Denise E. Bruns, BS

* New Jersey VA Medical Center, East Orange, New Jersey, USA
{dagger} Ochsner Clinic, New Orleans, Louisiana, USA
{ddagger} Krannert Institute of Cardiology, Indianapolis, Indiana, USA
§ Hartford Hospital, Hartford, Connecticut, USA
|| Georgetown University Medical Center, Washington, D.C., USA
Molecular Biosystems, Inc., San Diego, California, USA

Manuscript received November 26, 1997; revised manuscript received April 30, 1998, accepted May 15, 1998.

Address for correspondence: Jerald L. Cohen, MD, Cardiology Section, New Jersey VA Medical Center, 385 Tremont Avenue, East Orange, New Jersey 07018

Objectives. The echocardiographic contrast-enhancing effects and safety profile of ALBUNEX (a suspension of air-filled albumin microspheres) were compared with the new contrast agent OPTISON (formerly FS069: a suspension of albumin microspheres containing the gas perfluoropropane) in 203 patients with inadequate noncontrast echocardiograms.

Background. The efficacy of ALBUNEX has been limited by its short duration of action. By using perfluoropropane instead of air within the microsphere, its duration of action is increased.

Methods. Each patient received ALBUNEX (0.8 and 0.22 mL/kg) and OPTISON (0.2, 0.5, 3.0, and 5.0 mL) on separate days a minimum of 48 hours apart. Echocardiograms were evaluated for increase in left ventricular (LV) endocardial border length, degree of LV opacification, number of LV endocardial border segments visualized, conversion from a nondiagnostic to a diagnostic echocardiogram, and duration of contrast enhancement. A thorough safety evaluation was conducted.

Results. Compared with ALBUNEX, OPTISON more significantly improved every measure of contrast enhancement. OPTISON increased well-visualized LV endocardial border length by 6.0 ± 5.1, 6.9 ± 5.4, 7.5 ± 4.7, and 7.6 ± 4.8 cm, respectively, for each of the four doses, compared with only 2.2 ± 4.5 and 3.4 ± 4.6 cm, respectively, for the two ALBUNEX doses (p < 0.001). 100% LV opacification was achieved in 61%, 73%, 87%, and 87% of the patients with the four doses of OPTISON, but in only 16% and 36% of the patients with the two ALBUNEX doses (p < 0.001). Conversion of nondiagnostic to diagnostic echocardiograms with contrast occurred in 74% of patients with the optimal dose of OPTISON (3.0 mL) compared with only 26% with the optimal dose of ALBUNEX (0.22 mL/kg) (p < 0.001). The duration of contrast effect was also significantly greater with OPTISON than with ALBUNEX. In a subset of patients with potentially poor transpulmonary transit of contrast (patients with chronic lung disease or dilated cardiomyopathy), OPTISON more significantly improved the same measures of contrast enhancement compared with ALBUNEX and did so to the same extent as in the overall population. Side effects were similar and transient with the two agents.

Conclusion. OPTISON appears to be a safe, well-tolerated echocardiographic contrast agent that is superior to ALBUNEX.

Abbreviations and Acronyms
  ECG = electrocardiogram
  LV = left ventricular




This article has been cited by other articles:


Home page
Eur J EchocardiogrHome page
R. Senior, H. Becher, M. Monaghan, L. Agati, J. Zamorano, J. L. Vanoverschelde, and P. Nihoyannopoulos
Contrast echocardiography: evidence-based recommendations by European Association of Echocardiography
Eur J Echocardiogr, March 1, 2009; 10(2): 194 - 212.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. S. Dolan, S. S. Gala, S. Dodla, S. S. Abdelmoneim, F. Xie, D. Cloutier, M. Bierig, S. L. Mulvagh, T. R. Porter, and A. J. Labovitz
Safety and efficacy of commercially available ultrasound contrast agents for rest and stress echocardiography a multicenter experience.
J. Am. Coll. Cardiol., January 6, 2009; 53(1): 32 - 38.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. L. Main, J. H. Goldman, and P. A. Grayburn
Thinking Outside the "Box" The Ultrasound Contrast Controversy
J. Am. Coll. Cardiol., December 18, 2007; 50(25): 2434 - 2437.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
R. Olszewski, J. Timperley, S. Cezary, M. Monaghan, P. Nihoyannopoulis, R. Senior, and H. Becher
The clinical applications of contrast echocardiography
Eur J Echocardiogr, June 1, 2007; 8(3): s13 - s23.
[Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
T. Geisler, H.C. Rost, P.S. Wild, and R. Zotz
Freehand three-dimensional assessment of left ventricular volumes and ejection fraction with ultrasound contrast agent LK565
Eur J Echocardiogr, January 1, 2007; 8(1): 19 - 29.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
G. A. Whalley, G. D. Gamble, H. J. Walsh, N. Sharpe, and R. N. Doughty
Quantitative evaluation of regional endocardial visualisation with second harmonic imaging and contrast left ventricular opacification in heart failure patients
Eur J Echocardiogr, March 1, 2005; 6(2): 134 - 143.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
H Becher, J Chambers, K Fox, R Jones, G J Leech, N Masani, M Monaghan, R More, P Nihoyannopoulos, H Rimington, et al.
BSE procedure guidelines for the clinical application of stress echocardiography, recommendations for performance and interpretation of stress echocardiography: A report of the British Society of Echocardiography Policy Committee
Heart, December 1, 2004; 90(suppl_6): vi23 - vi30.
[Full Text] [PDF]


Home page
RadiologyHome page
Y. Kono, S. P. Pinnell, C. B. Sirlin, S. R. Sparks, B. Georgy, W. Wong, and R. F. Mattrey
Carotid Arteries: Contrast-enhanced US Angiography--Preliminary Clinical Experience
Radiology, February 1, 2004; 230(2): 561 - 568.
[Abstract] [Full Text] [PDF]


Home page
Eur J Heart FailHome page
G. A. Whalley, G. D. Gamble, H. J. Walsh, S. P. Wright, S. Agewall, N. Sharpe, and R. N. Doughty
Effect of tissue harmonic imaging and contrast upon between observer and test-retest reproducibility of left ventricular ejection fraction measurement in patients with heart failure
Eur J Heart Fail, January 1, 2004; 6(1): 85 - 93.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
J. A. Fox, V. Formanek, A. Friedrich, and S. K. Shernan
Intraoperative Echocardiography
Card. Surg. Adult, January 1, 2003; 2(2003): 283 - 314.
[Full Text]


Home page
J Ultrasound MedHome page
J. F. Zachary, S. A. Hartleben, L. A. Frizzell, and W. D. O'Brien Jr
Arrhythmias in Rat Hearts Exposed to Pulsed Ultrasound After Intravenous Injection of a Contrast Agent
J. Ultrasound Med., December 1, 2002; 21(12): 1347 - 1356.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J SupplHome page
H. Becher, K. Tiemann, S. Kuntz-Hehner, H. Omran, and T. Schlosser
Diagnostic impact of contrast echocardiography for assessment of left ventricular function and myocardial perfusion in patients with coronary artery disease
Eur. Heart J. Suppl., March 1, 2002; 4(suppl_C): C12 - C21.
[Abstract] [PDF]


Home page
ChestHome page
T. T. Nguyen, M. R. Dhond, R. Sabapathy, and W. J. Bommer
Contrast Microbubbles Improve Diagnostic Yield in ICU Patients With Poor Echocardiographic Windows
Chest, October 1, 2001; 120(4): 1287 - 1292.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
H. L. Thomson, A.-J. Basmadjian, A. J. Rainbird, M. Razavi, J.-F. Avierinos, P. A. Pellikka, K. R. Bailey, J. F. Breen, and M. Enriquez-Sarano
Contrast echocardiography improves the accuracy and reproducibility of left ventricular remodeling measurements: A prospective, randomly assigned, blinded study
J. Am. Coll. Cardiol., September 1, 2001; 38(3): 867 - 875.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Kuntz-Hehner, J. Goenechea, C. Pohl, T. Schlosser, C. Veltmann, C. Lentz, S. Lohmaier, A. Ehlgen, H. Omran, H. Becher, et al.
Continuous-Infusion Contrast-enhanced US: In Vitro Studies of Infusion Techniques with Different Contrast Agents
Radiology, September 1, 2001; 220(3): 647 - 654.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
V. Mor-Avi, E. G. Caiani, K. A. Collins, C. E. Korcarz, J. E. Bednarz, and R. M. Lang
Combined Assessment of Myocardial Perfusion and Regional Left Ventricular Function by Analysis of Contrast-Enhanced Power Modulation Images
Circulation, July 17, 2001; 104(3): 352 - 357.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
M. J K Blomley, J. C Cooke, E. C Unger, M. J Monaghan, and D. O Cosgrove
Science, medicine, and the future: Microbubble contrast agents: a new era in ultrasound
BMJ, May 19, 2001; 322(7296): 1222 - 1225.
[Full Text]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
K. Suehiro, S. Takuma, C. Cardinale, T. Hozumi, J. Shimizu, H. Yano, M. R. Di Tullio, J. Wang, C. R. Smith, D. Burkhoff, et al.
Assessment of segmental wall motion abnormalities using contrast two-dimensional echocardiography in awake mice
Am J Physiol Heart Circ Physiol, April 1, 2001; 280(4): H1729 - H1735.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. Poldermans, J. J. Bax, A. Elhendy, F. Sozzi, E. Boersma, I. R. Thomson, and L. J. Jordaens
Long-term Prognostic Value of Dobutamine Stress Echocardiography in Patients With Atrial Fibrillation
Chest, January 1, 2001; 119(1): 144 - 149.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
G. Mychaskiw II, A. E. Badr, R. Tibbs, B. R. Clower, and J. H. Zhang
Optison (FS069) Disrupts the Blood-Brain Barrier in Rats
Anesth. Analg., October 1, 2000; 91(4): 798 - 803.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. K. Heinle, J. Noblin, P. Goree-Best, A. Mello, G. Ravad, S. Mull, P. Mammen, and P. A. Grayburn
Assessment of Myocardial Perfusion by Harmonic Power Doppler Imaging at Rest and During Adenosine Stress : Comparison With 99mTc-Sestamibi SPECT Imaging
Circulation, July 4, 2000; 102(1): 55 - 60.
[Abstract] [Full Text] [PDF]


Home page
Journal of Diagnostic Medical SonographyHome page
S. M. Bierig, J. V. Chapman, C. Newman, and V. Zuck
Contrast Echocardiography in Clinical Practice: Integration of Contrast Echocardiography
Journal of Diagnostic Medical Sonography, May 1, 2000; 16(3): 97 - 102.
[Abstract] [PDF]


Home page
CirculationHome page
W. A. Zoghbi and E. Barasch
Dobutamine MRI: : A Serious Contender in Pharmacological Stress Imaging?
Circulation, February 16, 1999; 99(6): 730 - 732.
[Full Text] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement