JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1998; 31:1391-1394
© 1998 by the American College of Cardiology Foundation
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gold, M.
Right arrow Articles by Shorofsky,
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gold, M.
Right arrow Articles by Shorofsky, , SR

Comparison of single- and dual-coil active pectoral defibrillation lead systems

MR Gold, MR Olsovsky, MA Pelini, RW Peters, and Shorofsky SR

Department of Medicine, University of Maryland School of Medicine, Baltimore, USA. MGold@medicine.ab.umd.edu

OBJECTIVES: The purpose of this study was to compare defibrillation thresholds with lead systems consisting of an active left pectoral electrode and either single or dual transvenous coils. BACKGROUND: Lead systems that include an active pectoral pulse generator reduce defibrillation thresholds and permit transvenous defibrillation in nearly all patients. A further improvement in defibrillation efficacy is desirable to allow for smaller pulse generators with a reduced maximal output. METHODS: This prospective study was performed in 50 consecutive patients. Each patient was evaluated with two lead configurations with the order of testing randomized. Shocks were delivered between the right ventricular coil and either an active can alone (single coil) or an active can with the proximal atrial coil (dual coil). The right ventricular coil was the cathode for the first phase of the biphasic defibrillation waveform. RESULTS: Delivered energy at the defibrillation threshold was 10.1+/-5.0 J for the single-coil configuration and 8.7+/-4.0 J for the dual-coil configuration (p < 0.02). Moreover, 98% of patients had low (<15 J) thresholds with the dual-coil lead system, compared with 88% of patients with the single-coil configuration (p=0.05). Leading edge voltage (p < 0.001) and shock impedance (p < 0.001) were also decreased with the dual-coil configuration, although peak current was increased (p < 0.001). CONCLUSIONS: A dual-coil, active pectoral lead system reduces defibrillation energy requirements compared with a single-coil, unipolar configuration.


This article has been cited by other articles:


Home page
CirculationHome page
C. Butter, E. Meisel, J. Tebbenjohanns, L. Engelmann, E. Fleck, B. Schubert, S. Hahn, and D. Pfeiffer
Transvenous Biventricular Defibrillation Halves Energy Requirements in Patients
Circulation, November 20, 2001; 104(21): 2533 - 2538.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
B. Schulte, J. Sperzel, J. Carlsson, T. Schwarz, W. Ehrlich, H. F. Pitschner, and J. Neuzner
Dual-coil vs single-coil active pectoral implantable defibrillator lead systems: defibrillation energy requirements and probability of defibrillation success at multiples of the defibrillation energy requirements
Europace, January 1, 2001; 3(3): 177 - 180.
[Abstract] [PDF]


Home page
CirculationHome page
P. N. Schauerte, K. Ziegert, M. Waldmann, F. A. Schondube, F. Birkenhauer, K. Mischke, M. Grossmann, P. Hanrath, and C. Stellbrink
Effect of Biphasic Shock Duration on Defibrillation Threshold With Different Electrode Configurations and Phase 2 Capacitances : Prediction by Upper-Limit-of-Vulnerability Determination
Circulation, March 23, 1999; 99(11): 1516 - 1522.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. R. Gold, S. Higgins, R. Klein, F. R. Gilliam, H. Kopelman, S. Hessen, J. Payne, S. A. Strickberger, D. Breiter, and S. Hahn
Efficacy and Temporal Stability of Reduced Safety Margins for Ventricular Defibrillation: Primary Results From the Low Energy Safety Study (LESS)
Circulation, April 30, 2002; 105(17): 2043 - 2048.
[Abstract] [Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1998 by the American College of Cardiology Foundation.