JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1998; 31:878-882
© 1998 by the American College of Cardiology Foundation
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Masura, J
Right arrow Articles by Hijazi, Z.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Masura, J
Right arrow Articles by Hijazi, Z.

Catheter closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: immediate and short-term results

J Masura, KP Walsh, B Thanopoulous, C Chan, J Bass, Y Goussous, P Gavora, and ZM Hijazi

Department of Cardiology, Children University Hospital, Bratislava, Slovak Republic.

OBJECTIVES: The aim of this study was to assess the immediate and short-term results of anterograde catheter closure of a moderate- to large-sized patent ductus arteriosus (PDA) using the new self-expandable, respositionable Amplatzer duct occluder (ADO) device. BACKGROUND: Transcatheter closure of a PDA using devices or coils is technically challenging and may be accompanied by a 38% incidence of residual shunts. METHODS: Twenty-four patients (6 male, 18 female) underwent attempted transcatheter closure of a PDA using the ADO at a median age of 3.8 years (range 0.4 to 48) and a median weight of 15.5 kg (range 6 to 70). The mean PDA diameter at its narrowest segment was 3.7+/-1.5 mm. A 6F long sheath was used for delivery of the ADO. Follow-up evaluation was performed with color flow mapping of the main pulmonary artery within 24 h and at 1 and 3 months after closure. RESULTS: Twenty three of the 24 patients had successful device placement. Angiography showed that 7 patients had complete immediate closure, 14 had a trace shunt (foaming through the device with no jet), and 2 had a small residual shunt (with a jet). Within 24 h, color Doppler revealed complete closure in all patients. The unsuccessful attempt was during an initial trial with a prototype that has been modified. The median fluoroscopy time was 13.5 min (range 6.3 to 47). All patients were discharged home the next day. There were no complications. Of the 23 patients, 21 completed the 1-month follow-up, all (95% confidence interval [CI] 86% to 100%) with complete closure, and 18 of 23 patients completed the 3-month follow-up, also all (95% CI 83% to 100%) with complete closure. CONCLUSIONS: Anterograde transcatheter closure using the new ADO is an effective therapy for patients with a PDA diameter up to 6 mm. Further clinical trials are underway.


This article has been cited by other articles:


Home page
CirculationHome page
R. J. Sommer, Z. M. Hijazi, and J. F. Rhodes Jr
Pathophysiology of Congenital Heart Disease in the Adult: Part I: Shunt Lesions
Circulation, February 26, 2008; 117(8): 1090 - 1099.
[Full Text] [PDF]


Home page
HeartHome page
C Yan, S Zhao, S Jiang, Z Xu, L Huang, H Zheng, J Ling, C Wang, W Wu, H Hu, et al.
Transcatheter closure of patent ductus arteriosus with severe pulmonary arterial hypertension in adults
Heart, April 1, 2007; 93(4): 514 - 518.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
M O. Galal, M. Amin, A. Hussein, A. Kouatli, J. Al-Ata, and A. Jamjoom
Left Ventricular Dysfunction after Closure of Large Patent Ductus Arteriosus
Asian Cardiovasc Thorac Ann, March 1, 2005; 13(1): 24 - 29.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
G Butera, G De Rosa, M Chessa, L Piazza, A Delogu, A Frigiola, and M Carminati
Transcatheter closure of persistent ductus arteriosus with the Amplatzer duct occluder in very young symptomatic children
Heart, December 1, 2004; 90(12): 1467 - 1470.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J.-F. Piechaud
Closing down: transcatheter closure of intracardiac defects and vessel embolisations
Heart, December 1, 2004; 90(12): 1505 - 1510.
[Full Text] [PDF]


Home page
ANGIOLOGYHome page
A. Rangel, H. Perez-Redondo, J. Farell, M. N. Basave, and C. Zamora
Division or Occlusion of Patent Ductus Arteriosus?
Angiology, November 1, 2003; 54(6): 695 - 700.
[Abstract] [PDF]


Home page
BMJHome page
K. P Walsh
Interventional paediatric cardiology
BMJ, August 16, 2003; 327(7411): 385 - 388.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. J. Morgan-Hughes, J. Villaquiran, C. A. Roobottom, N. J. Ring, J. Kuo, and A. J. Marshall
Calcified patent ductus arteriosus diagnosed following aortic valve replacement
Ann. Thorac. Surg., July 1, 2003; 76(1): 271 - 273.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
B D Thanopoulos, G S Tsaousis, M Djukic, F Al Hakim, N G Eleftherakis, and S D Simeunovic
Transcatheter closure of high pulmonary artery pressure persistent ductus arteriosus with the Amplatzer muscular ventricular septal defect occluder
Heart, March 1, 2002; 87(3): 260 - 263.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
A.G Magee, I.C Huggon, P.T Seed, S.A Qureshi, M Tynan, and on behalf of the Association for European Paediatr
Transcatheter coil occlusion of the arterial duct. Results of the European Registry
Eur. Heart J., October 1, 2001; 22(19): 1817 - 1821.
[Abstract] [PDF]


Home page
HeartHome page
G Fischer, J Stieh, A Uebing, R Grabitz, and H H Kramer
Transcatheter closure of persistent ductus arteriosus in infants using the Amplatzer duct occluder
Heart, October 1, 2001; 86(4): 444 - 447.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. A. Bilkis, M. Alwi, S. Hasri, A. L. Haifa, K. Geetha, M. A. Rehman, and I. Hasanah
The Amplatzer duct occluder: experience in 209 patients
J. Am. Coll. Cardiol., January 1, 2001; 37(1): 258 - 261.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. J. Lipton, L. M. Boxt, and Z. M. Hijazi
Role of the Radiologist in Cardiac Diagnostic Imaging
Am. J. Roentgenol., December 1, 2000; 175(6): 1495 - 1506.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
B. D. Thanopoulos, F. A. Hakim, A. Hiari, Y. Goussous, E. Basta, A. A. Zarayelyan, and G. S. Tsaousis
Further experience with transcatheter closure of the patent ductus arteriosus using the Amplatzer duct occluder
J. Am. Coll. Cardiol., March 15, 2000; 35(4): 1016 - 1021.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
C A C Pedra, J Pihkala, D G Nykanen, and L N Benson
Antegrade transcatheter closure of coronary artery fistulae using vascular occlusion devices
Heart, January 1, 2000; 83(1): 94 - 96.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
C Duke and K C Chan
Aortic obstruction caused by device occlusion of patent arterial duct
Heart, July 1, 1999; 82(1): 109 - 111.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. S. Rao, S. H. Kim, J.-Y. Choi, C. Rey, J. Haddad, F. Marcon, K. Walsh, and E. B. Sideris
Follow-up results of transvenous occlusion of patent ductus arteriosus with the buttoned device
J. Am. Coll. Cardiol., March 1, 1999; 33(3): 820 - 826.
[Abstract] [Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1998 by the American College of Cardiology Foundation.