|
|
||||||||||
|
J Am Coll Cardiol, 1998; 31:534-540 © 1998 by the American College of Cardiology Foundation |
Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor. otto@pet.wayne.edu
OBJECTIVES: Regional myocardial blood flow (MBF) and flow reserve measurements using nitrogen-13 (N-13) ammonia positron emission tomography (PET) were compared with quantitative coronary angiography to determine their utility in the detection of significant coronary artery disease (CAD). BACKGROUND: Dynamic PET protocols using N-13 ammonia allow regional quantification of MBF and flow reserve. To establish the diagnostic performance of this method, the sensitivity and specificity must be known for varying decision thresholds. METHODS: MBF and flow reserve for three coronary territories were determined in 20 normal subjects and 31 patients with angiographically documented CAD by means of dynamic PET and a three-compartment model for N-13 ammonia kinetics. Ten normal subjects defined the normal mean and SD of MBF and flow reserve, and 10 normal subjects were compared with patients. PET flow obtained in the territory with the most severe stenosis in each patient was correlated with the angiographic assessment of the stenosis (severity > or = 50%, > or = 70%, > or = 90%). Receiver operating characteristic (ROC) curve analysis was performed for 1.5, 2.0, 2.5, 3.0 and 4.0 SD of flow abnormalities. RESULTS: MBF and flow reserve values from the normal subjects and from territories with documented stenoses > or = 50% were significantly different (p < 0.05). A significant difference was found between normal subjects and angiographically normal territories of patients with CAD. High diagnostic accuracy and sensitivity, with moderately high specificity, were demonstrated for detection of all stenoses. CONCLUSIONS: Quantification of myocardial perfusion using dynamic PET and N-13 ammonia provides a high performance level for the detection and localization of CAD. The specificity of dynamic PET was excellent in patients with a low likelihood of CAD, whereas an abnormal flow reserve in angiographically normal territories was postulated to represent early functional abnormalities of vascular reactivity.
This article has been cited by other articles:
![]() |
J. J. Dasselaar, R. H. J. A. Slart, M. Knip, J. Pruim, R. A. Tio, C. W. McIntyre, P. E. de Jong, and C. F. M. Franssen Haemodialysis is associated with a pronounced fall in myocardial perfusion Nephrol. Dial. Transplant., September 4, 2008; (2008) gfn501v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
J Knuuti and F M Bengel Positron emission tomography and molecular imaging Heart, March 1, 2008; 94(3): 360 - 367. [Abstract] [Full Text] [PDF] |
||||
![]() |
E Eroglu, J D'hooge, G R Sutherland, A Marciniak, D Thijs, W Droogne, L Herbots, J Van Cleemput, P Claus, B Bijnens, et al. Quantitative dobutamine stress echocardiography for the early detection of cardiac allograft vasculopathy in heart transplant recipients Heart, February 1, 2008; 94(2): e3 - e3. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Alessio, S. Kohlmyer, K. Branch, G. Chen, J. Caldwell, and P. Kinahan Cine CT for Attenuation Correction in Cardiac PET/CT J. Nucl. Med., May 1, 2007; 48(5): 794 - 801. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. K. Attili and P. N. Cascade CT and MRI of Coronary Artery Disease:Evidence-Based Review. Am. J. Roentgenol., December 1, 2006; 187(6 Suppl): S483 - S499. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. F. Rodrigues de Avila, J. L. Fernandes, C. E. Rochitte, G. G. Cerri, and J. P. Filho Perfusion Impairment in Patients with Normal-appearing Coronary Arteries: Identification with Contrast-enhanced MR Imaging Radiology, December 21, 2005; (2005) 2382041697. [Abstract] [Full Text] |
||||
![]() |
A. Khorsand, S. Graf, H. Eidherr, W. Wadsak, K. Kletter, H. Sochor, E. Schuster, and G. Porenta Gated Cardiac 13N-NH3 PET for Assessment of Left Ventricular Volumes, Mass, and Ejection Fraction: Comparison with Electrocardiography-Gated 18F-FDG PET J. Nucl. Med., December 1, 2005; 46(12): 2009 - 2013. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Schwaiger, S. Ziegler, and S. G. Nekolla PET/CT: Challenge for Nuclear Cardiology J. Nucl. Med., October 1, 2005; 46(10): 1664 - 1678. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Fenchel, A. Franow, N. I. Stauder, U. Kramer, U. Helber, C. D. Claussen, and S. Miller Myocardial Perfusion after Angioplasty in Patients Suspected of Having Single-Vessel Coronary Artery Disease: Improvement Detected at Rest-Stress First-Pass Perfusion MR Imaging--Initial Experience Radiology, October 1, 2005; 237(1): 67 - 74. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Klem, W. G. Rehwald, J. F. Heitner, A. Wagner, T. Albert, M. A. Parker, E.-L. Chen, R. J. Kim, and R. M. Judd Noninvasive Assessment of Blood Flow Based on Magnetic Resonance Global Coherent Free Precession Circulation, March 1, 2005; 111(8): 1033 - 1039. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. J. C. Alders, A. B. J. Groeneveld, F. J. J. de Kanter, and J. H. G. M. van Beek Myocardial O2 consumption in porcine left ventricle is heterogeneously distributed in parallel to heterogeneous O2 delivery Am J Physiol Heart Circ Physiol, September 1, 2004; 287(3): H1353 - H1361. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Nagel, C. Klein, I. Paetsch, S. Hettwer, B. Schnackenburg, K. Wegscheider, and E. Fleck Magnetic Resonance Perfusion Measurements for the Noninvasive Detection of Coronary Artery Disease Circulation, July 29, 2003; 108(4): 432 - 437. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Frouin, P. Merlet, Y. Bouchareb, V. Frouin, J.-L. Dubois-Rande, A. De Cesare, A. Herment, A. Syrota, and A. Todd-Pokropek Validation of Myocardial Perfusion Reserve Measurements Using Regularized Factor Images of H215O Dynamic PET Scans J. Nucl. Med., December 1, 2001; 42(12): 1737 - 1746. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. W. Koskenvuo, J. J. Hartiala, J. Knuuti, H. Sakuma, J. O. Toikka, M. Komu, M. Saraste, and P. Niemi Assessing Coronary Sinus Blood Flow in Patients with Coronary Artery Disease: A Comparison of Phase-Contrast MR Imaging with Positron Emission Tomography Am. J. Roentgenol., November 1, 2001; 177(5): 1161 - 1166. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Kern and B. Meier Evaluation of the Culprit Plaque and the Physiological Significance of Coronary Atherosclerotic Narrowings Circulation, June 26, 2001; 103(25): 3142 - 3149. [Full Text] [PDF] |
||||
![]() |
J. Schwitter, D. Nanz, S. Kneifel, K. Bertschinger, M. Buchi, P. R. Knusel, B. Marincek, T. F. Luscher, and G. K. von Schulthess Assessment of Myocardial Perfusion in Coronary Artery Disease by Magnetic Resonance : A Comparison With Positron Emission Tomography and Coronary Angiography Circulation, May 8, 2001; 103(18): 2230 - 2235. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Al-Saadi, E. Nagel, M. Gross, A. Bornstedt, B. Schnackenburg, C. Klein, W. Klimek, H. Oswald, and E. Fleck Noninvasive Detection of Myocardial Ischemia From Perfusion Reserve Based on Cardiovascular Magnetic Resonance Circulation, March 28, 2000; 101(12): 1379 - 1383. [Abstract] [Full Text] [PDF] |
||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |