Advertisement






Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1997; 30:1735-1740
© 1997 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Browne, K.
Right arrow Articles by Brenner, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Browne, K.
Right arrow Articles by Brenner, A.

Initial experience with reuse of coronary angioplasty catheters in the United States

KF Browne, R Maldonado, M Telatnik, RE Vlietstra, and AS Brenner

Watson Clinic, Lakeland, FL 33805, USA. kbrowne@watsonclinic.com

OBJECTIVES: We sought to evaluate the performance of angioplasty catheters, restored under a strict manufacturing process, in patients with coronary artery disease. BACKGROUND: Most countries outside the United States routinely reuse disposable medical equipment, resulting in significant cost savings. Because of quality and legal concerns, reuse in the United States has been limited. We investigated the reuse of percutaneous transluminal coronary angioplasty (PTCA) balloon catheters, restored by a process strictly controlled for bioburden and sterility, in patients undergoing PTCA. METHODS: Used PTCA balloon catheters were shipped to a central facility and were decontaminated, cleaned and tested for endotoxin using the limulus amebocyte lystate (LAL) gel clot method. Physical testing and quality assurance were performed. The products were packaged and sterilized with ethylene oxide. Catheter performance was assessed in a pilot study powered to detect a 5% difference in the angiographic failure rates of new and reused balloons (beta 0.8). RESULTS: The study enrolled 107 patients. The indication for PTCA was stable angina pectoris in 69 patients, unstable angina in 22 and acute myocardial infarction in 16. Of the 107 patients enrolled, 106 had a successful laboratory outcome, and 1 required coronary artery bypass graft surgery after failed rescue stenting. There were 122 lesions attempted (American College of Cardiology/American Heart Association classification A, n = 32; B1, n = 43; > or = B2, n = 35; C, n = 12). Of the 110 lesions initially approached with restored PTCA catheters, 108 were crossed and dilated. Sixty-four required no further procedures. Stenting was performed in 37 patients (29 planned, 8 rescue). Thus, the angiographic failure rate was 7% (10 of 108, 95% confidence interval 2% to 12%), comparable to the 10% rate seen with new balloons in other studies. CONCLUSIONS: Restoration of disposable coronary angioplasty catheters using a highly controlled process appears to be safe and effective, with success rates similar to those of new products and no detectable sacrifice in performance. Cost analysis suggests that implementation of reuse technology for expensive disposable equipment may offer cost savings for U.S. hospitals, without sacrifice of quality.


This article has been cited by other articles:


Home page
J Biomater ApplHome page
D. Behrend, G. Zinner, K. Sternberg, M. Schroeder, K. P. Schmitz, and A. Haubold
Assessment of Explanted PTCA Balloons
J Biomater Appl, October 1, 2000; 15(2): 160 - 167.
[Abstract] [PDF]


Home page
Anesth. Analg.Home page
M. D. W. Lipp, G. Jaehnichen, N. Golecki, G. Fecht, R. Reichl, and P. Heeg
Microbiological, Microstructure, and Material Science Examinations of Reprocessed Combitubes(R) After Multiple Reuse
Anesth. Analg., September 1, 2000; 91(3): 693 - 697.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
G. Krause, G. Dziekan, and F.D. Daschner
Reuse of coronary angioplasty balloon catheters: yes or no?
Eur. Heart J., February 1, 2000; 21(3): 185 - 189.
[PDF]


Home page
JWatch GeneralHome page
REUSE OF CORONARY ANGIOPLASTY CATHETERS APPEARS SAFE
Journal Watch (General), December 5, 1997; 1997(1205): 6 - 6.
[Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement