JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1997; 30:1324-1330
© 1997 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lok, N.
Right arrow Articles by Ayers, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lok, N.
Right arrow Articles by Ayers, G.

Clinical shock tolerability and effect of different right atrial electrode locations on efficacy of low energy human transvenous atrial defibrillation using an implantable lead system

NS Lok, CP Lau, HF Tse, and GM Ayers

Department of Medicine, Queen Mary Hospital, Hong Kong, People's Republic of China.

OBJECTIVES: The objectives of this study were 1) to evaluate the effect of different right atrial electrode locations on the efficacy of low energy transvenous defibrillation with an implantable lead system; and 2) to qualitate and quantify the discomfort from atrial defibrillation shocks delivered by a clinically relevant method. BACKGROUND: Biatrial shocks result in the lowest thresholds for transvenous atrial defibrillation, but the optimal right atrial and coronary sinus electrode locations for defibrillation efficacy in humans have not been defined. METHODS: Twenty-eight patients (17 men, 11 women) with chronic atrial fibrillation (AF) (lasting > or = 1 month) were studied. Transvenous atrial defibrillation was performed by delivering R wave-synchronized biphasic shocks with incremental shock levels (from 180 to 400 V in steps of 40 V). Different electrode location combinations were used and tested randomly: the anterolateral, inferomedial right atrium or high right atrial appendage to the distal coronary sinus. Defibrillation thresholds were defined in duplicate by using the step-up protocol. Pain perception of shock delivery was assessed by using a purpose-designed questionnaire; sedation was given when the shock level was unacceptable (tolerability threshold). RESULTS: Sinus rhythm was restored in 26 of 28 patients by using at least one of the right atrial electrode locations tested. The conversion rate with the anterolateral right atrial location (21 [81%] of 26) was higher than that with the inferomedial right atrial location (8 [50%] of 16, p < 0.05) but similar to that with the high right atrial appendage location (16 [89%] of 18, p > 0.05). The mean defibrillation thresholds for the high right atrial appendage, anterolateral right atrium and inferomedial right atrium were all significantly different with respect to energy (3.9 +/- 1.8 J vs. 4.6 +/- 1.8 J vs. 6.0 +/- 1.7 J, respectively, p < 0.05) and voltage (317 +/- 77 V vs. 348 +/- 70 V vs. 396 +/- 66 V, respectively, p < 0.05). Patients tolerated a mean of 3.4 +/- 2 shocks with a tolerability threshold of 255 +/- 60 V, 2.5 +/- 1.3 J. CONCLUSIONS: Low energy transvenous defibrillation with an implantable defibrillation lead system is an effective treatment for AF. Most patients can tolerate two to three shocks, and, when the starting shock level (180 V) is close to the defibrillation threshold, they can tolerate on average a shock level of 260 V without sedation. Electrodes should be positioned in the distal coronary sinus and in the high right atrial appendage to achieve the lowest defibrillation threshold, although other locations may be suitable for certain patients.


This article has been cited by other articles:


Home page
EuropaceHome page
S. J. Walsh, G. Manoharan, O. J. Escalona, J. Santos, N. Evans, J. McC. Anderson, M. Stevenson, J. D. Allen, and A.A. J. Adgey
Novel rectangular biphasic and monophasic waveforms delivered by a radiofrequency-powered defibrillator compared with conventional capacitor-based waveforms in transvenous cardioversion of atrial fibrillation.
Europace, October 1, 2006; 8(10): 873 - 880.
[Abstract] [Full Text] [PDF]


Home page
Psychosom. Med.Home page
J. Baumert, C. Schmitt, and K.-H. Ladwig
Psychophysiologic and Affective Parameters Associated With Pain Intensity of Cardiac Cardioverter Defibrillator Shock Discharges
Psychosom Med, July 1, 2006; 68(4): 591 - 597.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J.C. Geller, S. Reek, C. Timmermans, T. Kayser, H.-F. Tse, C. Wolpert, W. Jung, A.J. Camm, C.-P. Lau, H. J.J. Wellens, et al.
Treatment of atrial fibrillation with an implantable atrial defibrillator -- long term results
Eur. Heart J., December 1, 2003; 24(23): 2083 - 2089.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. H. Everett IV, J. G. Akar, L.-C. Kok, J. R. Moorman, and D. E. Haines
Use of global atrial fibrillation organization to optimize the success of burst pace termination
J. Am. Coll. Cardiol., November 20, 2002; 40(10): 1831 - 1840.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
I. Mirza, S. James, and P. Holt
Biatrial pacing for paroxysmal atrial fibrillation: A randomized prospective study into the suppression of paroxysmal atrial fibrillation using biatrial pacing
J. Am. Coll. Cardiol., August 7, 2002; 40(3): 457 - 463.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
G. Lehmann, J. Horcher, K. Dennig, A. Plewan, K. Ulm, and E. Alt
Atrial Mechanical Performance After Internal and External Cardioversion of Atrial Fibrillation : An Echocardiographic Study
Chest, January 1, 2002; 121(1): 13 - 18.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
A. R. J. Mitchell, P. A. R. Spurrell, K. Kamalvand, M. Higson, R. Shanmuganathan, N. R. Patel, and N. Sulke
What is the optimal electrode configuration for atrial defibrillators in man?
Europace, January 1, 2002; 4(1): 41 - 44.
[Full Text] [PDF]


Home page
Eur Heart JHome page
P.E. Vardas, E.G. Manios, E.M. Kanoupakis, D.N. Dermitzaki, H.E. Mavrakis, and E.M. Kallergis
Atrial defibrillation threshold in humans minutes after atrial fibrillation induction. 'a stitch in time saves nine'
Eur. Heart J., September 1, 2001; 22(17): 1613 - 1617.
[Abstract] [PDF]


Home page
CirculationHome page
X. Zheng, M. E. Benser, G. P. Walcott, and R. E. Ideker
Right Atrial Septal Electrode for Reducing the Atrial Defibrillation Threshold
Circulation, August 28, 2001; 104(9): 1066 - 1070.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
T. H. Everett IV, J. R. Moorman, L.-C. Kok, J. G. Akar, and D. E. Haines
Assessment of Global Atrial Fibrillation Organization to Optimize Timing of Atrial Defibrillation
Circulation, June 12, 2001; 103(23): 2857 - 2861.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. G. Daoud, C. Timmermans, C. Fellows, R. Hoyt, R. Lemery, K. Dawson, and G. M. Ayers
Initial Clinical Experience With Ambulatory Use of an Implantable Atrial Defibrillator for Conversion of Atrial Fibrillation
Circulation, September 19, 2000; 102(12): 1407 - 1413.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. Ammer, G.u. Lehmann, A. Plewan, K. Puetter, and E. Alt
Marked reduction in atrial defibrillation thresholds with repeated internal cardioversion
J. Am. Coll. Cardiol., November 1, 1999; 34(5): 1569 - 1576.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. Timmermans, A. Nabar, L.-M. Rodriguez, G. Ayers, and H. J. J. Wellens
Use of Sedation During Cardioversion With the Implantable Atrial Defibrillator
Circulation, October 5, 1999; 100(14): 1499 - 1501.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
H.-F. Tse, C.-P. Lau, B. M. Yomtov, and G. M. Ayers
Implantable atrial defibrillator with a single-pass dual-electrode lead
J. Am. Coll. Cardiol., June 1, 1999; 33(7): 1974 - 1980.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. Timmermans, L.-M. Rodriguez, G. M. Ayers, H. Lambert, J. L. R. M. Smeets, J. W. S. Vlaeyen, A. Albert, and H. J. J. Wellens
Effect of Butorphanol Tartrate on Shock-Related Discomfort During Internal Atrial Defibrillation
Circulation, April 13, 1999; 99(14): 1837 - 1842.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C.-P. Lau, H.-F. Tse, and G. M. Ayers
Defibrillation-guided radiofrequency ablation of atrial fibrillation secondary to an atrial focus
J. Am. Coll. Cardiol., April 1, 1999; 33(5): 1217 - 1226.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
H. J. J. Wellens, C.-P. Lau, B. Luderitz, M. Akhtar, A. L. Waldo, A. J. Camm, C. Timmermans, H.-F. Tse, W. Jung, L. Jordaens, et al.
Atrioverter: An Implantable Device for the Treatment of Atrial Fibrillation
Circulation, October 20, 1998; 98(16): 1651 - 1656.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. L. Waldo
Low-Energy Atrial Defibrillation : A Promising New Technique
Circulation, September 1, 1998; 98(9): 833 - 834.
[Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1997 by the American College of Cardiology Foundation.