J Am Coll Cardiol, 1997; 30:834-842 © 1997 by the American College of Cardiology Foundation |
Oregon Health Sciences University, Portland, Oregon, USA.
OBJECTIVES: The aim of the present study was to quantitate aortic regurgitant volume and regurgitant fraction in a chronic animal model with surgically created aortic regurgitation using a new semiautomated color Doppler flow calculation method. BACKGROUND: The conventional noninvasive methods for evaluating the severity of aortic regurgitation have not been accepted widely nor compared with truly quantitative reference standards. METHODS: Eight to 20 weeks after aortic regurgitation was surgically induced in six sheep, a total of 22 hemodynamic states were studied. Electromagnetic flow probes and meters provided reference flow data. Epicardial color Doppler echocardiographic studies were performed to image left ventricular outflow tract forward and aortic regurgitant blood flows. The new method digitally integrated spatial and temporal color flow velocity data for left ventricular outflow tract forward flow and ascending aortic regurgitant flow. The pulsed Doppler method using the velocity-time integral was also used to obtain regurgitant volumes and regurgitant fractions. RESULTS: Regurgitant volumes and regurgitant fractions by the new method agreed well with those obtained electromagnetically, whereas the pulsed Doppler method overestimated these reference data (mean [+/-SD] difference 0.23 +/- 2.9 ml vs. 11 +/- 5.8 ml, p < 0.0001 for regurgitant volume; mean difference 1.2 +/- 7.6% vs. 19 +/- 13%, p < 0.0001 for regurgitant fraction). CONCLUSIONS: This animal study, using strictly quantified aortic regurgitant volumes, demonstrated that the digital color Doppler method provides accurate aortic regurgitant volumes and regurgitant fractions without cumbersome measurements.
This article has been cited by other articles:
![]() |
Y Miyake, T Hozumi, I Mori, K Sugioka, A Yamamuro, T Akasaka, S Homma, K Yoshida, and J Yoshikawa Automated quantification of aortic regurgitant volume and regurgitant fraction using the digital colour Doppler velocity profile integration method in patients with aortic regurgitation Heart, December 1, 2002; 88(5): 481 - 484. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Mori, R. A. Rusk, M. Jones, X.-N. Li, T. Irvine, A. D. Zetts, and D. J. Sahn A new dynamic three-dimensional digital color doppler method for quantification of pulmonary regurgitation: validation study in an animal model J. Am. Coll. Cardiol., September 18, 2002; 40(6): 1179 - 1185. [Abstract] [Full Text] [PDF] |
||||
![]() |
T Shiota Automated cardiac flow measurement by digital colour Doppler echocardiography Heart, September 1, 2002; 88(3): 211 - 212. [Full Text] [PDF] |
||||
![]() |
Y Ueda, T Hozumi, K Yoshida, H Watanabe, T Akasaka, T Takagi, A Yamamuro, S Homma, and J Yoshikawa Non-invasive automated assessment of the ratio of pulmonary to systemic flow in patients with atrial septal defects by the colour Doppler velocity profile integration method Heart, September 1, 2002; 88(3): 278 - 282. [Abstract] [Full Text] [PDF] |
||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |