JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1997; 30:649-656
© 1997 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hamburger, J.
Right arrow Articles by Serruys, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hamburger, J.
Right arrow Articles by Serruys, P.

Recanalization of chronic total coronary occlusions using a laser guide wire: a pilot study

JN Hamburger, GH Gijsbers, Y Ozaki, PN Ruygrok, PJ de Feyter, and PW Serruys

Thoraxcenter, University Hospital Rotterdam, The Netherlands. hamburge@card.azr.nl

OBJECTIVES: This study sought to prospectively evaluate the performance of a laser guide wire in crossing chronic total coronary occlusions in patients with a failed previous mechanical guide wire attempt. BACKGROUND: Despite continued refinement of mechanical hardware available for coronary angioplasty, restoration and maintenance of blood flow through a chronically occluded coronary artery remains a true challenge. METHODS: Fifty patients with a chronic total coronary occlusion and a previous failed attempt at recanalization using mechanical guide wires were included. A mechanical attempt to cross the occlusion was repeated. In case of failure, an additional attempt was made with the laser guide wire. RESULTS: The median age of occlusion was 22 weeks (range 5 to 200), and the occlusion length was 23 +/- 11 mm (mean +/- SD). A repeat mechanical attempt was successful in six cases (12%). Dissection occurred in five other cases, and device crossover was not attempted. Thus, in 39 patients an attempt was made with the laser guide wire, with successful recanalization in 23 (59%). Thereby the overall success rate increased from 12% to 58% (29 of 50 patients). The amount of contrast medium used was 515 +/- 154 ml, fluoroscopy time was 99 +/- 43 min, and total procedure time was 2 h 48 min (+/- 55 min). Procedural success was achieved in 26 cases and clinical success (procedural success without in hospital events) in 24. In-hospital events were two non-Q wave myocardial infarctions related to subacute reocclusion. In one patient, a balloon dilation after laser guide wire perforation resulted in tamponade requiring pericardiocentesis. After a successful procedure, the angina class decreased from 2.9 +/- 0.2 to 1.4 +/- 0.7 at 3 months of clinical follow-up. Six month angiographic follow-up was completed in all 24 eligible patients and showed vessel patency in 20 (80%). CONCLUSIONS: The use of the laser guide wire for recanalization of chronic total coronary occlusions refractory to treatment with mechanical guide wires is feasible and relatively safe and was successful in 59% of cases. This device must thus be considered a valuable addition to the interventional armamentarium and accordingly will be evaluated in a randomized clinical trial.


This article has been cited by other articles:


Home page
Eur Heart JHome page
P.W Serruys, J.N Hamburger, J Fajadet, M Haude, H Klues, R Seabra-Gomes, T Corcos, C Hamm, L Pizzuli, B Meier, et al.
Total occlusion trial with angioplasty by using laser guidewire. The TOTAL trial
Eur. Heart J., November 1, 2000; 21(21): 1797 - 1805.
[Abstract] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1997 by the American College of Cardiology Foundation.