JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1997; 30:561-568
© 1997 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nishioka, T
Right arrow Articles by Siegel, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nishioka, T
Right arrow Articles by Siegel, R.

Dissolution of thrombotic arterial occlusion by high intensity, low frequency ultrasound and dodecafluoropentane emulsion: an in vitro and in vivo study

T Nishioka, H Luo, MC Fishbein, B Cercek, JS Forrester, CJ Kim, H Berglund, and RJ Siegel

Division of Health Control Medicine, Ground Self Defense Force Medical School, Tokyo, Japan.

OBJECTIVES: We examined the effectiveness of the microbubbles of an echo contrast agent, dodecafluoropentane (DDFP) emulsion, to enhance low frequency ultrasound clot disruption in vitro and in vivo. BACKGROUND: Ultrasound is reported to facilitate clot dissolution, and microbubbles could theoretically enhance ultrasound clot dissolution by augmenting cavitational effects. METHODS: In vitro studies: The disruption rate of fresh human clots by ultrasound (24 kHz, 2.9 W/cm2) was examined in saline and DDFP emulsion. In vivo studies: Using a rabbit iliofemoral thrombotic occlusion model, recanalization rate and histopathologic findings were compared among groups treated with DDFP emulsion alone, transcutaneous ultrasound (20 kHz, 1.5 W/cm2) alone and with DDFP emulsion and ultrasound combined. RESULTS: The ultrasound clot disruption rate was significantly (p < 0.01) increased, from 72 +/- 18% (mean +/- SD) in saline to 98 +/- 4% in DDFP emulsion in 3 min in vitro. No vessel was recanalized by DDFP emulsion alone (0%), and only a single artery was patent after ultrasound treatment alone (9%). In contrast, 82% of iliofemoral arteries were angiographically recanalized after ultrasound treatment with DDFP emulsion. Histologically, the patent arteries had only minimal focal mural thrombus, with no evidence of vessel wall damage. However, substantial damage was observed in rabbit dermis and subcutaneous tissue. CONCLUSIONS: 1) DDFP emulsion, an echo contrast agent, significantly enhances the clot-disrupting effect of low frequency ultrasound in vitro and in an in vivo rabbit iliofemoral occlusion model. 2) This simple combination therapy has potential for clinical application in patients with thrombotic arterial occlusions.


This article has been cited by other articles:


Home page
Eur J EchocardiogrHome page
P.A Dijkmans, L.J.M Juffermans, R.J.P Musters, A van Wamel, F.J ten Cate, W van Gilst, C.A Visser, N de Jong, and O Kamp
Microbubbles and ultrasound: from diagnosis to therapy
Eur J Echocardiogr, August 1, 2004; 5(4): 245 - 246.
[Abstract] [Full Text] [PDF]


Home page
Vasc MedHome page
C. W Francis and V. N Suchkova
Ultrasound and thrombolysis
Vascular Medicine, August 1, 2001; 6(3): 181 - 187.
[Abstract] [PDF]


Home page
CirculationHome page
V. N. Suchkova, R. B. Baggs, and C. W. Francis
Effect of 40-kHz Ultrasound on Acute Thrombotic Ischemia in a Rabbit Femoral Artery Thrombosis Model : Enhancement of Thrombolysis and Improvement in Capillary Muscle Perfusion
Circulation, May 16, 2000; 101(19): 2296 - 2301.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
V. Suchkova, F. N. Siddiqi, E. L. Carstensen, D. Dalecki, S. Child, and C. W. Francis
Enhancement of Fibrinolysis With 40-kHz Ultrasound
Circulation, September 8, 1998; 98(10): 1030 - 1035.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
Y. Birnbaum, H. Luo, T. Nagai, M. C. Fishbein, T. M. Peterson, S. Li, D. Kricsfeld, T. R. Porter, and R. J. Siegel
Noninvasive In Vivo Clot Dissolution Without a Thrombolytic Drug : Recanalization of Thrombosed Iliofemoral Arteries by Transcutaneous Ultrasound Combined With Intravenous Infusion of Microbubbles
Circulation, January 20, 1998; 97(2): 130 - 134.
[Abstract] [Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1997 by the American College of Cardiology Foundation.