Advertisement






Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1997; 30:436-443
© 1997 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by von Birgelen, C
Right arrow Articles by Serruys, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by von Birgelen, C
Right arrow Articles by Serruys, P.

Electrocardiogram-gated intravascular ultrasound image acquisition after coronary stent deployment facilitates on-line three-dimensional reconstruction and automated lumen quantification

C von Birgelen, GS Mintz, A Nicosia, DP Foley, WJ van der Giessen, N Bruining, SG Airiian, Roelandt JR, PJ de Feyter, and PW Serruys

Thoraxcenter, University Hospital Rotterdam-Dijkzigt, The Netherlands.

OBJECTIVE: This study evaluates the feasibility, reliability and reproducibility of electrocardiogram (ECG)-gated intravascular ultrasound (IVUS) image acquisition during automated transducer withdrawal and automated three-dimensional (3D) boundary detection for assessing on-line the result of coronary stenting. BACKGROUND: Systolic-diastolic image artifacts frequently limit the clinical applicability of such automated analysis systems. METHODS: In 30 patients, after successful angiography-guided implantation of 34 stents in 30 target lesions, we carried out IVUS examinations on-line with the use of ECG-gated automated 3D analyses and conventional manual analyses of two-dimensional images from continuous pullbacks. These on-line measurements were compared with off-line 3D reanalyses. The adequacy of stent deployment was determined by using ultrasound criteria for stent apposition, symmetry and expansion. RESULTS: Gated image acquisition was successfully performed in all patients to allow on-line 3D analysis within 8.7 +/- 0.6 min (mean +/- SD). Measurements by on-line and off-line 3D analyses correlated closely (r > or = 0.95), and the minimal stent lumen differed only minimally (8.6 +/- 2.8 mm2 vs. 8.5 +/- 2.8 mm2, p = NS). The conventional analysis significantly overestimated the minimal stent lumen (9.0 +/- 2.7 mm2, p < 0.005) in comparison with results of both 3D analyses. Fourteen stents (41%) failed to meet the criteria by both 3D analyses, all of these not reaching optimal expansion, but only 7 (21%) were detected by conventional analysis (p < 0.02). Intraobserver and interobserver comparison of stent lumen measurements by the automated approach revealed minimal differences (0.0 +/- 0.2 mm2 and 0.0 +/- 0.3 mm2) and excellent correlations (r = 0.99 and 0.98, respectively). CONCLUSIONS: ECG-gated image acquisition after coronary stent deployment is feasible, permits on-line automated 3D reconstruction and analysis and provides reliable and reproducible measurements; these factors facilitate detection of the minimal lumen site.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
H. Futamatsu, M. Sabate, D. J. Angiolillo, P. Jimenez-Quevedo, C. Corros, K. Morikawa-Futamatsu, F. Alfonso, J. Jiang, P. Cervinka, R. Hernandez-Antolin, et al.
Characterization of Plaque Prolapse After Drug-Eluting Stent Implantation in Diabetic Patients: A Three-Dimensional Volumetric Intravascular Ultrasound Outcome Study
J. Am. Coll. Cardiol., September 19, 2006; 48(6): 1139 - 1145.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. J. B. Kutryk, D. P. Foley, M. van den Brand, J. N. Hamburger, W. J. van der Giessen, P. J. deFeyter, N. Bruining, M. Sabate, and P. W. Serruys
Local intracoronary administration of antisense oligonucleotide against c-myc for the prevention of in-stent restenosis: Results of the randomized investigation by the thoraxcenter of antisense dna using local delivery and ivus after coronary stenting (ITALICS) trial
J. Am. Coll. Cardiol., January 16, 2002; 39(2): 281 - 287.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
I. P. Kay, A. J. Wardeh, K. Kozuma, G. Sianos, E. Regar, M. Knook, W. J. van der Giessen, A. Thury, J. M. R. Ligthart, V. M. A. Coen, et al.
The pattern of restenosis and vascular remodelling after cold-end adioactive stent implantation
Eur. Heart J., August 1, 2001; 22(15): 1311 - 1317.
[Abstract] [PDF]


Home page
CirculationHome page
I. P. Kay, A. J. Wardeh, K. Kozuma, D. P. Foley, A. H. M. Knook, A. Thury, G. Sianos, W. J. van der Giessen, P. C. Levendag, and P. W. Serruys
Radioactive Stents Delay but Do Not Prevent In-Stent Neointimal Hyperplasia
Circulation, January 2, 2001; 103(1): 14 - 17.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
I. P. Kay, M. Sabate, M. A. Costa, K. Kozuma, M. Albertal, W. J. van der Giessen, A. J. Wardeh, J. M. R. Ligthart, V. M. A. Coen, P. C. Levendag, et al.
Positive Geometric Vascular Remodeling Is Seen After Catheter-Based Radiation Followed by Conventional Stent Implantation but Not After Radioactive Stent Implantation
Circulation, September 19, 2000; 102(12): 1434 - 1439.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Fateh-Moghadam, W. Bocksch, A. Ruf, T. Dickfeld, M. Schartl, G. Pogatsa-Murray, R. Hetzer, E. Fleck, and M. Gawaz
Changes in Surface Expression of Platelet Membrane Glycoproteins and Progression of Heart Transplant Vasculopathy
Circulation, August 22, 2000; 102(8): 890 - 897.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. Sabate, J. P. A. Marijnissen, S. G. Carlier, I. P. Kay, W. J. van der Giessen, V. L. M. A. Coen, J. M. R. Ligthart, E. Boersma, M. A. Costa, P. C. Levendag, et al.
Residual Plaque Burden, Delivered Dose, and Tissue Composition Predict 6-Month Outcome After Balloon Angioplasty and {beta}-Radiation Therapy
Circulation, May 30, 2000; 101(21): 2472 - 2477.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
C Schulz, R A Herrmann, C Beilharz, J Pasquantonio, and E Alt
Coronary stent symmetry and vascular injury determine experimental restenosis
Heart, April 1, 2000; 83(4): 462 - 467.
[Abstract] [Full Text]


Home page
CirculationHome page
P. J. de Feyter, P. Kay, C. Disco, and P. W. Serruys
Reference Chart Derived From Post-Stent-Implantation Intravascular Ultrasound Predictors of 6-Month Expected Restenosis on Quantitative Coronary Angiography
Circulation, October 26, 1999; 100(17): 1777 - 1783.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. Sabate, I. P. Kay, W. J. van der Giessen, A. Cequier, J. M. R. Ligthart, J. A. Gomez-Hospital, S. G. Carlier, V. L. M. A. Coen, J. P. A. Marijnissen, A. J. Wardeh, et al.
Preserved Endothelium-Dependent Vasodilation in Coronary Segments Previously Treated With Balloon Angioplasty and Intracoronary Irradiation
Circulation, October 12, 1999; 100(15): 1623 - 1629.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
Acute Platelet Inhibition With Abciximab Does Not Reduce In-Stent Restenosis (ERASER Study)
Circulation, August 24, 1999; 100(8): 799 - 806.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A. S. Turk, C. M. Strother, D. I. Crouthamel, and J. A. Zagzebski
Definition of the Ostium (Neck) of an Aneurysm Revealed by Intravascular Sonography: An Experimental Study in Canines,<$DOWNLINK>
AJNR Am. J. Neuroradiol., August 1, 1999; 20(7): 1301 - 1308.
[Abstract] [Full Text]


Home page
HeartHome page
C von Birgelen, G S Mintz, E A de Vrey, T Kimura, J J Popma, S G Airiian, M B Leon, M Nobuyoshi, P W Serruys, and P J de Feyter
Atherosclerotic coronary lesions with inadequate compensatory enlargement have smaller plaque and vessel volumes: observations with three dimensional intravascular ultrasound in vivo
Heart, February 1, 1998; 79(2): 137 - 142.
[Abstract] [Full Text]


Home page
CirculationHome page
C. von Birgelen, E. A. de Vrey, G. S. Mintz, A. Nicosia, N. Bruining, W. Li, C. J. Slager, J. R. T. C. Roelandt, P. W. Serruys, and P. J. de Feyter
ECG-Gated Three-dimensional Intravascular Ultrasound : Feasibility and Reproducibility of the Automated Analysis of Coronary Lumen and Atherosclerotic Plaque Dimensions in Humans
Circulation, November 4, 1997; 96(9): 2944 - 2952.
[Abstract] [Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement