Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1984; 3:1367-1374
© 1984 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Port, S.
Right arrow Articles by Schmidt, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Port, S.
Right arrow Articles by Schmidt, D.

Effects of intraaortic balloon counterpulsation on myocardial blood flow in patients with severe coronary artery disease

SC Port, S Patel, and DH Schmidt

The purpose of this study was to test the hypothesis that myocardial blood flow distal to a critical stenosis would increase during intraaortic balloon counterpulsation. Accordingly, 13 patients with severe coronary artery disease were studied at the time of elective preoperative insertion of an intraaortic balloon catheter. Hemodynamic measurements and measurements of myocardial blood flow were made before and during counterpulsation. Myocardial blood flow was measured with a xenon-133 washout technique. Compared with control measurements, the heart rate decreased from 87.8 +/- 18.8 to 82.8 +/- 13.4 beats/min (p = 0.02) and systolic arterial pressure decreased from 112.1 +/- 17.9 to 97.8 +/- 14.8 mm Hg (p = 0.004) during counterpulsation. Diastolic arterial pressure increased from 72.2 +/- 10.1 to 120.2 +/- 21.4 mm Hg (p = 0.00002) during counterpulsation. Myocardial blood flow for the entire group decreased from 48.8 +/- 14.1 to 42.6 +/- 11.0 ml/100 g per min (p = 0.008). Regional flows in the left anterior descending and circumflex distributions also decreased. Left anterior descending artery blood flow decreased insignificantly from 51.5 +/- 14.4 to 47.4 +/- 11.7 ml/100 g per min (p = not significant), while circumflex flow decreased from 50.7 +/- 12.2 to 41.1 +/- 8.9 ml/100 g per min (p = 0.008). When normalized for the rate-pressure product, myocardial blood flow was 53 +/- 16 X 10(-4) at rest and 55 +/- 12 X 10(-4) (p = not significant) during counterpulsation.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
M. Takeuchi, Y. Nohtomi, H. Yoshitani, C. Miyazaki, K. Sakamoto, and J. Yoshikawa
Enhanced coronary flow velocity during intra-aortic balloon pumping assessed by transthoracic doppler echocardiography
J. Am. Coll. Cardiol., February 4, 2004; 43(3): 368 - 376.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
E Eeckhout and M.J Kern
The coronary no-reflow phenomenon: a review of mechanisms and therapies
Eur. Heart J., May 1, 2001; 22(9): 729 - 739.
[PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement