JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1984; 3:1005-1012
© 1984 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rocchini, A.
Right arrow Articles by Rosenthal, A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rocchini, A.
Right arrow Articles by Rosenthal, A

Percutaneous balloon valvuloplasty for treatment of congenital pulmonary valvular stenosis in children

AP Rocchini, DA Kveselis, D Crowley, M Dick, and A Rosenthal

Percutaneous balloon pulmonary valvuloplasty was performed in seven children with moderate to severe valvular pulmonary stenosis (right ventricular to pulmonary artery pressure gradient greater than 50 mm Hg). All patients experienced a decrease in right ventricular peak systolic pressure from 108 +/- 30 to 60 +/- 5.6 mm Hg (p less than 0.001), decrease in right ventricular to pulmonary artery gradient from 90.1 +/- 30 to 38.8 +/- 5 mm Hg (p less than 0.001) and increase in pulmonary valve area from 0.33 +/- 0.06 to 0.55 +/- 0.15 cm2/m2 (p less than 0.001). In the two patients who underwent supine bicycle exercise before and after valvuloplasty, a significant decrease in both the maximal right ventricular peak systolic pressure (212 to 140 and 175 to 125 mm Hg, respectively) and in right ventricular to pulmonary artery peak pressure gradient (185 to 110 and 151 to 85 mm Hg, respectively) occurred. All patients tolerated the procedure well and no serious complications were observed. It is concluded that percutaneous balloon valvuloplasty is a safe and effective method for relief of right ventricular obstruction due to moderate or severe valvular pulmonary stenosis. However, long-term results remain unknown.


This article has been cited by other articles:


Home page
ANGIOLOGYHome page
T.-L. Jaing, B. Hwang, J.-H. Lu, K.-S. Hsieh, and C.C. L. Meng
Percutaneous Balloon Valvuloplasty in Severe Pulmonary Valvular Stenosis
Angiology, June 1, 1995; 46(6): 503 - 509.
[Abstract] [PDF]


Home page
CirculationHome page
K. Neya, R. Lee, J. L. Guerrero, P. Lang, and G. J. Vlahakes
Experimental Ablation of Outflow Tract Muscle With a Thermal Balloon Catheter
Circulation, May 1, 1995; 91(9): 2445 - 2453.
[Abstract] [Full Text]


Home page
VASC ENDOVASCULAR SURGHome page
J. T. Walls, Z. Lababidi, and J. J. Curtis
Surgical Evaluation of Percutaneous Transluminal Balloon Angioplasty and Valvuloplasty in Congenital Cardiovascular Anomalies
Vascular and Endovascular Surgery, July 1, 1988; 22(4): 253 - 257.
[Abstract] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1984 by the American College of Cardiology Foundation.