JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1984; 3:789-798
© 1984 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Starling, M.
Right arrow Articles by Nusynowitz, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Starling, M.
Right arrow Articles by Nusynowitz, M.

Accurate estimates of absolute left ventricular volumes from equilibrium radionuclide angiographic count data using a simple geometric attenuation correction

MR Starling, LJ Dell'Italia, RA Walsh, WC Little, AR Benedetto, and ML Nusynowitz

To simplify and clarify the methods of obtaining attenuation-corrected equilibrium radionuclide angiographic estimates of absolute left ventricular volumes, 27 patients who also had biplane contrast cineangiography were evaluated. Background-corrected left ventricular end-diastolic and end-systolic counts were obtained by semiautomated variable and hand-drawn regions of interest and were normalized to cardiac cycles processed, frame rate and blood sample counts. Blood sample counts were acquired on (d degree) and at a distance (d') from the collimator. A simple geometric attenuation correction was performed to obtain absolute left ventricular volume estimates. Using blood sample counts obtained at d degree or d', the attentuation-corrected radionuclide left ventricular end-diastolic volume estimates using both region of interest selection methods correlated with the cineangiographic end-diastolic volumes (r = 0.95 to 0.96). However, both mean radionuclide semiautomated variable left ventricular end-diastolic volumes (179 +/- 100 [+/- 1 standard deviation] and 185 +/- 102 ml, p less than 0.001) were smaller than the average cineangiographic end-diastolic volume (217 +/- 102 ml), and both mean hand-drawn left ventricular end-diastolic volumes (212 +/- 104 and 220 +/- 106 ml) did not differ from the average cineangiographic end-diastolic volume. Using the blood sample counts obtained at d degree or d', the attenuation-corrected radionuclide left ventricular end-systolic volume estimates using both region of interest selection methods correlated with the cineangiographic end-systolic volumes (r = 0.96 to 0.98). Also, using blood sample counts at d degree, the mean radionuclide semiautomated variable left ventricular end-systolic volume (116 +/- 98 ml, p less than 0.05) was less than the average cineangiographic end-systolic volume (128 +/- 98 ml), and the other radionuclide end-systolic volumes did not differ from the average cineangiographic end-systolic volume. Therefore, it is concluded that: 1) a simple geometric attenuation-correction of radionuclide left ventricular end-diastolic and end-systolic count data provides accurate estimates of biplane cineangiographic end-diastolic and end-systolic volumes; and 2) the hand-drawn region of interest selection method, unlike the semiautomated variable method that underestimates end-diastolic and end-systolic volumes, provides more accurate estimates of biplane cineangiographic left ventricular volumes irrespective of the distance blood sample counts are acquired from the collimator.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
W. O. Ntim and W. G. Hundley
Cardiac Imaging in Patients With Chronic Obstructive Pulmonary Disease and Chronic Heart Failure
J. Am. Coll. Cardiol., May 8, 2007; 49(18): 1900 - 1901.
[Full Text] [PDF]


Home page
JNMHome page
K. Nakajima, T. Higuchi, J. Taki, M. Kawano, and N. Tonami
Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Myocardial SPECT: Comparison of 4 Software Programs
J. Nucl. Med., October 1, 2001; 42(10): 1571 - 1578.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
W. H. Devlin, J. Petrusha, K. Briesmiester, D. Montgomery, and M. R. Starling
Impact of Vascular Adaptation to Chronic Aortic Regurgitation on Left Ventricular Performance
Circulation, March 2, 1999; 99(8): 1027 - 1033.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. R. Starling
Effects of Valve Surgery on Left Ventricular Contractile Function in Patients With Long-term Mitral Regurgitation
Circulation, August 15, 1995; 92(4): 811 - 818.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1984 by the American College of Cardiology Foundation.