Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1984; 3:733-743
© 1984 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rasmussen, S
Right arrow Articles by Corya, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rasmussen, S
Right arrow Articles by Corya, B.

Echocardiographic detection of ischemic and infarcted myocardium

S Rasmussen, DE Lovelace, SB Knoebel, R Ransburg, and BC Corya

The purpose of this study was to determine the potential of a clinically adaptable two-dimensional echocardiographic system using computer enhancement and a mathematically defined integrated backscatter ratio for the early detection of ischemic and infarcted myocardium. Fifteen dogs had two-dimensional echocardiograms recorded during either open chest coronary occlusion (n = 5), closed chest occlusion (n = 5), occlusion followed by reperfusion (n = 3) or sham coronary occlusion (n = 2). A serial increase in integrated backscatter ratio, representing differences in returned ultrasound intensities between a reference point and specific myocardial regions, was detected between 7 and 12 minutes of complete occlusion in 9 of 12 animals (p less than 0.05), and at minutes 18, 43 and 67 in the remaining 3 animals. Reperfusion after 20 minutes of occlusion in two studies resulted in normalization of the backscatter ratio. An increase in backscatter ratio was not detected when 5 minute occlusion periods were used or during the 5 hour sham occlusion studies. The computer enhancement techniques utilized in this study provided increased visual detail of intracardiac structures over that provided by routine two-dimensional echocardiograms; myocardial tissue was identifiable in what appeared to be echo-free segments; and boundaries that appeared as noncontiguous horizontal lines on the routine echocardiograms were identifiable as trabeculae. The results indicate that: 1) significant increases in backscatter from nonperfused myocardium are detectable echocardiographically within 12 minutes of coronary occlusion and temporal changes can be assessed in the canine model, and 2) the echocardiographic data acquisition and computer analysis system utilized provide a clinically adaptable approach to identify and map myocardial characteristics in human beings.


This article has been cited by other articles:


Home page
Eur Heart J Cardiovasc ImagingHome page
R. Lasserre, P. Gosse, and S. Mansour
Myocardial Tissue Characterization in Echocardiography with Videodensitometry: Evaluation of a New Semi-automatic Software Applied on a Population of Hypertensive Patients
Eur Heart J Cardiovasc Imaging, December 1, 2003; 4(4): 292 - 299.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. F. Vitale, R. O. Bonow, G. Gerundo, N. Pelaggi, G. Lauria, D. Leosco, F. Coltorti, C. Bordini, C. Rengo, and F. Rengo
Alterations in Ultrasonic Backscatter During Exercise-Induced Myocardial Ischemia in Humans
Circulation, September 15, 1995; 92(6): 1452 - 1457.
[Abstract] [Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement