Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1984; 3:14-20
© 1984 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Feinstein, S.
Right arrow Articles by Corday, E
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Feinstein, S.
Right arrow Articles by Corday, E

Two-dimensional contrast echocardiography. I. In vitro development and quantitative analysis of echo contrast agents

SB Feinstein, FJ Ten Cate, W Zwehl, K Ong, G Maurer, C Tei, PM Shah, S Meerbaum, and E Corday

To facilitate the passage of echo contrast agents through the microcirculation and the echocardiographic study of myocardial perfusion, ultrasonic energy (sonication) was employed to produce contrast agents consisting of relatively uniform, stable and small (less than 10 mu diameter) gaseous microbubbles suspended in liquid solutions. The size and persistence of the microbubbles was verified by light microscopy and an in vitro system were employed for comparative assessment of peak echo amplitude and echo persistence characteristics of various contrast agents. The study indicated that although a variety of hand-agitated and sonicated contrast agents provided satisfactory echo intensities, sonication was clearly superior to the hand-agitation method, because sonication produced smaller, more uniform and more stable microbubbles that may be suitable for myocardial contrast echocardiography. It is concluded that of the contrast agents examined, sonicated solutions of sorbitol (70%) and dextrose (70%) appeared to have particular potential because of the small sizes of the microbubbles (6 +/- 2 and 8 +/- 3 mu, respectively) and their prolonged in vitro persistence. The use of sonication to produce standardized, small and stable microbubbles should facilitate physiologic passage of the contrast agent through the capillary beds and allow two-dimensional imaging of the left heart myocardium during right-sided, aortic root, coronary sinus or intracoronary contrast injections.


This article has been cited by other articles:


Home page
J Am Coll Cardiol ImgHome page
S. Kaul
Myocardial Contrast Echocardiography: A Wondrous Journey!
J. Am. Coll. Cardiol. Img., February 1, 2010; 3(2): 212 - 218.
[Full Text] [PDF]


Home page
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in MedicineHome page
E. P. Stride and C. C. Coussios
Cavitation and contrast: The use of bubbles in ultrasound imaging and therapy
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, February 1, 2010; 224(2): 171 - 191.
[Abstract] [PDF]


Home page
CirculationHome page
S. Kaul
Myocardial Contrast Echocardiography: A 25-Year Retrospective
Circulation, July 15, 2008; 118(3): 291 - 308.
[Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
S. B. Feinstein
The powerful microbubble: from bench to bedside, from intravascular indicator to therapeutic delivery system, and beyond
Am J Physiol Heart Circ Physiol, August 1, 2004; 287(2): H450 - H457.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D.-S. Jeon, H. Luo, T. Iwami, T. Miyamoto, A. V. Brasch, J. Mirocha, T. Z. Naqvi, and R. J. Siegel
The usefulness of a 10% air-10% blood-80% saline mixture for contrast echocardiography: Doppler measurement of pulmonary artery systolic pressure
J. Am. Coll. Cardiol., January 2, 2002; 39(1): 124 - 129.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Kaul
Myocardial Contrast Echocardiography : 15 Years of Research and Development
Circulation, November 18, 1997; 96(10): 3745 - 3760.
[Full Text]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
S. Aronson
Myocardial Contrast Echocardiography: Is it Ready to be Used as a Clinical Tool in the Operating Room?
Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 1997; 1(1): 4 - 15.
[PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
Q. Caretta, P. Voci, M. C. Acconcia, and F. Chiarotti
COLLATERAL FLOW PREVENTS UNINTENTIONAL MYOCARDIAL ISCHEMIA DURING ANTEGRADE CARDIOPLEGIA IN PATIENTS UNDERGOING CORONARY ARTERY BYPASS GRAFTING
J. Thorac. Cardiovasc. Surg., March 1, 1997; 113(3): 585 - 593.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
B. S. Allen, J. W. Winkelmann, H. Hanafy, R. S. Hartz, K. S. Bolling, J. Ham, and S. Feinstein
Retrograde cardioplegia does not adequately perfuse the right ventricle
J. Thorac. Cardiovasc. Surg., June 1, 1995; 109(6): 1116 - 1126.
[Abstract] [Full Text]


Home page
CirculationHome page
P. Voci, F. Bilotta, Q. Caretta, C. Mercanti, and B. Marino
Papillary Muscle Perfusion Pattern : A Hypothesis for Ischemic Papillary Muscle Dysfunction
Circulation, March 15, 1995; 91(6): 1714 - 1718.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
C. Quintilio, P. Voci, F. Bilotta, G. Luzi, F. Chiarotti, M. C. Acconcia, C. Mercanti, and B. Marino
Risk factors of incomplete distribution of cardioplegic solution during coronary artery grafting
J. Thorac. Cardiovasc. Surg., March 1, 1995; 109(3): 439 - 447.
[Abstract] [Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement