JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1997; 29:1296-1302
© 1997 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tardif, J.
Right arrow Articles by Mercier, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tardif, J.
Right arrow Articles by Mercier, L.

Simultaneous determination of aortic valve area by the Gorlin formula and by transesophageal echocardiography under different transvalvular flow conditions. Evidence that anatomic aortic valve area does not change with variations in flow in aortic stenosis

JC Tardif, AG Rodrigues, JF Hardy, Y Leclerc, R Petitclerc, R Mongrain, and LA Mercier

Department of Medicine, Montreal Heart Institute, University of Montreal, Quebec, Canada.

OBJECTIVES: The purpose of this study was to determine the impact of changes in flow on aortic valve area (AVA) as measured by the Gorlin formula and transesophageal echocardiographic (TEE) planimetry. BACKGROUND: The meaning of flow-related changes in AVA calculations using the Gorlin formula in patients with aortic stenosis remains controversial. It has been suggested that flow dependence of the calculated area could be due to a true widening of the orifice as flow increases or to a disproportionate flow dependence of the formula itself. Alternatively, anatomic AVA can be measured by direct planimetry of the valve orifice with TEE. METHODS: Simultaneous measurement of the planimetered and Gorlin valve area was performed intraoperatively under different hemodynamic conditions in 11 patients. Left ventricular and ascending aortic pressures were measured simultaneously after transventricular and aortic punctures. Changes in flow were induced by dobutamine infusion. Using multiplane TEE, AVA was planimetered at the level of the leaflet tips in the short-axis view. RESULTS: Overall, cardiac output, stroke volume and transvalvular volume flow rate ranged from 2.5 to 7.3 liters/min, from 43 to 86 ml and from 102 to 306 ml/min, respectively. During dobutamine infusion, cardiac-output increased by 42% and mean aortic valve gradient by 54%. When minimal flow was compared with maximal flow, the Gorlin area varied from (mean +/- SD) 0.44 +/- 0.12 to 0.60 +/- 0.14 cm2 (p < 0.005). The mean change in Gorlin area under different flow rates was 36 +/- 32%. Despite these changes, there was no significant change in the planimetered area when minimal flow was compared with maximal flow. The mean difference in planimetered area under different flow rates was 0.002 +/- 0.01 cm2 (p = 0.86). CONCLUSIONS: By simultaneous determination of Gorlin formula and TEE planimetry valve areas, we showed that acute changes in transvalvular volume flow substantially altered valve area calculated by the Gorlin formula but did not result in significant alterations of the anatomic valve area in aortic stenosis. These results suggest that the flow-related variation in the Gorlin AVA is due to a disproportionate flow dependence of the formula itself and not a true change in valve area.


This article has been cited by other articles:


Home page
Card Surg AdultHome page
T. Mihaljevic, M. R. Sayeed, S. C. Stamou, and S. Paul
Pathophysiology of Aortic Valve Disease
Card. Surg. Adult, January 1, 2008; 3(2008): 825 - 840.
[Full Text]


Home page
RadiologyHome page
A.-C. Pouleur, J.-B. le Polain de Waroux, A. Pasquet, J.-L. J. Vanoverschelde, and B. L. Gerber
Aortic Valve Area Assessment: Multidetector CT Compared with Cine MR Imaging and Transthoracic and Transesophageal Echocardiography
Radiology, September 1, 2007; 244(3): 745 - 754.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J Bermejo and R Yotti
Low-gradient aortic valve stenosis: value and limitations of dobutamine stress testing
Heart, March 1, 2007; 93(3): 298 - 302.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. Alkadhi, S. Wildermuth, A. Plass, D. Bettex, B. Baumert, S. Leschka, L. M. Desbiolles, B. Marincek, and T. Boehm
Aortic Stenosis: Comparative Evaluation of 16-Detector Row CT and Echocardiography
Radiology, July 1, 2006; 240(1): 47 - 55.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
L. Kadem, R. Rieu, J. G. Dumesnil, L.-G. Durand, and P. Pibarot
Flow-Dependent Changes in Doppler-Derived Aortic Valve Effective Orifice Area Are Real and Not Due to Artifact
J. Am. Coll. Cardiol., January 3, 2006; 47(1): 131 - 137.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
L. Kadem, R. Rieu, J. G. Dumesnil, L.-G. Durand, and P. Pibarot
Flow-Dependent Changes in Doppler-Derived Aortic Valve Effective Orifice Area Are Real and Not Due to Artifact
J. Am. Coll. Cardiol., December 14, 2005; (2005) j.jacc.2005.05.100v1.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. A. Busing, C. Schulte-Sasse, S. Fluchter, T. Suselbeck, K. K. Haase, W. Neff, J. G. Hirsch, M. Borggrefe, and C. Duber
Cerebral Infarction: Incidence and Risk Factors after Diagnostic and Interventional Cardiac Catheterization--Prospective Evaluation at Diffusion-weighted MR Imaging
Radiology, April 1, 2005; 235(1): 177 - 183.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. S. John, T. Dill, R. R. Brandt, M. Rau, W. Ricken, G. Bachmann, and C. W. Hamm
Magnetic resonance to assess the aortic valve area in aortic stenosis: How does it compare to current diagnostic standards?
J. Am. Coll. Cardiol., August 6, 2003; 42(3): 519 - 526.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
P. Das, H. Rimington, N. Smeeton, and J. Chambers
Determinants of symptoms and exercise capacity in aortic stenosis: a comparison of resting haemodynamics and valve compliance during dobutamine stress
Eur. Heart J., July 1, 2003; 24(13): 1254 - 1263.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
P. E. Gray and A. C. Perrino Jr.
Hemodynamic-Induced Changes in Aortic Valve Area: Implications for Doppler Cardiac Output Determinations
Anesth. Analg., March 1, 2001; 92(3): 584 - 589.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. Shandas, J. Kwon, and L. Valdes-Cruz
A Method for Determining the Reference Effective Flow Areas for Mechanical Heart Valve Prostheses : In Vitro Validation Studies
Circulation, April 25, 2000; 101(16): 1953 - 1959.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Arsenault, N. Masani, G. Magni, J. Yao, L. Deras, and N. Pandian
Variation of anatomic valve area during ejection in patients with valvular aortic stenosis evaluated by two-dimensional echocardiographic planimetry: comparison with traditional Doppler data
J. Am. Coll. Cardiol., December 1, 1998; 32(7): 1931 - 1937.
[Abstract] [Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1997 by the American College of Cardiology Foundation.