Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1997; 29:934-940
© 1997 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dean, L.
Right arrow Articles by Detre, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dean, L.
Right arrow Articles by Detre, K.

Bailout and corrective use of Gianturco-Roubin flex stents after percutaneous transluminal coronary angioplasty: operator reports and angiographic core laboratory verification from the National Heart, Lung, and Blood Institute/New Approaches to Coronary Intervention Registry

LS Dean, CJ George, GS Roubin, ED Kennard, DR Holmes Jr, SB King 3rd, RE Vlietstra, JW Moses, D Kereiakes, JP Carrozza Jr, SG Ellis, Margolis JR, and KM Detre

Department of Medicine, University of Alabama at Birmingham, 35294-0012, USA. ldean@uab.edu

OBJECTIVES: We sought to determine the in-hospital clinical outcome and angiographic results of patients prospectively entered into the National Heart, Lung, and Blood Institute/New Approaches to Coronary Intervention (NHLBI/NACI) Registry who received Gianturco-Roubin stents as an unplanned new device. BACKGROUND: Between August 1990 and March 1994, nine centers implanted Gianturco-Roubin flex stents as an unplanned new device in the initial treatment of 350 patients (389 lesions) who were prospectively enrolled in the NHLBI/NACI Registry. METHODS: Patients undergoing implantation of the Gianturco-Roubin flex stent were prospectively entered into the Gianturco-Roubin stent portion of the NHLBI/NACI Registry. Only subjects receiving the Gianturco-Roubin stent as a new device in an unplanned fashion are included. RESULTS: The mean age of the patient group was 61.8 years, and the majority of the patients were men. A history of percutaneous transluminal coronary angioplasty (PTCA) was present in 35.4% of the group, and 16.9% had previous coronary artery bypass graft surgery. Unstable angina was present in 67.7%. Double- or triple-vessel coronary artery disease was present in 55.4%, and the average ejection fraction was 58%. The presence of thrombus was noted in 7.3%, and 7.2% had moderate to severe tortuosity of the lesion. The angiographic success rate was 92%. Individual clinical sites reported that 66.3% of the stents were placed after suboptimal PTCA, 20.3% for abrupt closure and 13.4% for some other technical PTCA failure. Major in-hospital events occurred in 9.7% of patients, including death in 1.7%, Q wave myocardial infarction in 3.1% and emergency bypass surgery in 6%. Abrupt closure of a stented segment occurred in 3.1% of patients at a mean of 3.9 days. Cerebrovascular accident occurred in 0.3%, and transfusion was required in 10.6%. Vascular events with surgical repair occurred in 8.6% of patients. CONCLUSIONS: Despite these complications, the use of this device for the treatment of a failed or suboptimal PTCA result remains promising given the adverse outcome of abrupt closure with conventional (nonstent) treatment.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
T. M. Bashore, E. R. Bates, P. B. Berger, D. A. Clark, J. T. Cusma, G. J. Dehmer, M. J. Kern, W. K. Laskey, M. P. O'Laughlin, S. Oesterle, et al.
American College of Cardiology/Society for Cardiac Angiography and Interventions Clinical Expert Consensus Document on Cardiac Catheterization Laboratory Standards: A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents endorsed by the American Heart Association and the Diagnostic and Interventional Catheterization Committee of the Council on Clinical Cardiology of the AHA
J. Am. Coll. Cardiol., June 15, 2001; 37(8): 2170 - 2214.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. R. Holmes Jr., J. Hirshfeld Jr., D. Faxon, R. Vlietstra, A. Jacobs, S. B. King III, T. M. Bashore, N. D. Bridges, C. B. Higgins, L. F. Hiratzka, et al.
ACC expert consensus document on coronary artery stents: Document of the American College of Cardiology
J. Am. Coll. Cardiol., November 1, 1998; 32(5): 1471 - 1482.
[Full Text] [PDF]


Home page
HeartHome page
K K HAASE, A BAUMBACH, and K R KARSCH
Stents are used too often
Heart, June 1, 1998; 79(6): 541 - 542.
[Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement