JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1997; 29:825-830
© 1997 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fotuhi, P.
Right arrow Articles by Ideker, R.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Fotuhi, P.
Right arrow Articles by Ideker, R.

Effect of a passive endocardial electrode on defibrillation efficacy of a nonthoracotomy lead system

PC Fotuhi, BH Kenknight, SB Melnick, WM Smith, GF Baumann, and RE Ideker

Medical Clinic I, Charite Hospital, Berlin, Germany.

OBJECTIVES: We investigated the impact of an inactive endocardial lead on the 50% effective dose (ED50%) for successful ventricular defibrillation. BACKGROUND: The presence of abandoned epicardial mesh patch electrodes detrimentally affects the defibrillation efficacy of an endocardial lead system. It is not known whether abandoned endocardial electrodes produce a similar effect. METHODS: An endocardial lead system (ENDOTAK, model 0062, Cardiac Pacemakers, Inc.) was implanted in eight dogs (mean +/- SD weight 23.7 +/- 1.0 kg). The ED50% for each of seven lead configurations was determined by a three-reversal point protocol in a balanced-randomized order with and without a second electrically passive endocardial lead system in the right ventricle (power 0.97 to detect a 50-V difference). Biphasic shocks with 80% tilt were delivered 10 s after the induction of ventricular fibrillation. In one configuration the active electrode made contact with the passive electrode in the right ventricular (RV) apex. In another configuration the active electrode was placed in a more proximal position to avoid contact. Additionally, the ED50% was determined for the endocardial lead system with a passive pacing lead positioned in the RV apex. RESULTS: ED50% values for peak voltage, peak current and delivered energy were not significantly different with or without a passive RV electrode, and this was true whether or not the active electrode touched the passive electrode. However, ED50% values were significantly higher when the active electrode was slightly proximal than when it was positioned at the apex. CONCLUSIONS: Physical contact between active and passive endocardial electrodes does not significantly alter defibrillation efficacy in this dog model. An increase in ED50% energy was caused by a slightly proximal position. Therefore, a good electrode position within the right ventricle is a more important determinant of defibrillation efficacy than is avoidance of the electrode touching a passive electrode.


This article has been cited by other articles:


Home page
EuropaceHome page
J. M. Cooper, W. H. Sauer, F. C. Garcia, M. J. Krautkramer, and R. J. Verdino
Covering sleeves can shield the high-voltage coils from lead chatter in an integrated bipolar ICD lead
Europace, February 1, 2007; 9(2): 137 - 142.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
J. R. Paisey, A. M. Yue, F. Bessoule, P. R. Roberts, and J. M. Morgan
Passive electrode effect reduces defibrillation threshold in bi-filament middle cardiac vein defibrillation.
Europace, February 1, 2006; 8(2): 113 - 117.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
F. A. L. E. Bracke, A. Meijer, and L. M. van Gelder
Malfunction of endocardial defibrillator leads and lead extraction: where do they meet?
Europace, January 1, 2002; 4(1): 19 - 24.
[Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1997 by the American College of Cardiology Foundation.