Sustained local delivery of dexamethasone by a novel intravascular eluting stent to prevent restenosis in the porcine coronary injury model
AM Lincoff,
JG Furst,
SG Ellis,
RJ Tuch,
and
EJ Topol
Department of Cardiology, Cleveland Clinic Foundation, Ohio 44195, USA.
OBJECTIVES: This study sought to assess the feasibility, safety and efficacy of sustained intracoronary delivery of dexamethasone by a novel polymer-coated eluting stent. BACKGROUND: Development of techniques to provide sustained local drug delivery has focused on polymers as matrices for drug incorporation and elution. METHODS: A tantalum wire stent was coated with dexamethasone (0.8 mg) suspended in a matrix of either low (approximately 80 kD) or high (approximately 321 kD) molecular weight poly-L-lactic acid (PLLA [0.4 mg]). Uncoated stents, stents coated with PLLA or stents coated with dexamethasone in PLLA were overexpanded by 30% to the normal vessel diameter in the coronary arteries of juvenile farm pigs. Animals were euthanized 28 days later, and neointimal thicknesses were measured. Additional pigs underwent placement of stents coated with high molecular weight PLLA-dexamethasone for assessment of arterial tissue and serum concentrations of dexamethasone at 1 h and 1, 2, 10 and 28 days after stent implantation. RESULTS: In vitro dexamethasone release occurred over the first 6 days. Stents coated with low molecular weight PLLA produced an intense inflammatory neointimal response. Stents utilizing the high molecular weight PLLA were well tolerated within the coronary vessel during the 28-day experiment. However, dexamethasone did not decrease neointimal hyperplasia. Dexamethasone concentrations in the arterial tissue were approximately 300,000-fold higher than those in the serum 24 h after stent implantation, remaining approximately 3,000-fold higher at 28 days. CONCLUSIONS: The eluting stent utilizing high molecular weight PLLA appeared to be a well tolerated and effective means of providing sustained, site-specific drug delivery to the porcine coronary artery wall for at least 28 days.
This article has been cited by other articles:

|
 |

|
 |
 
K. Nakano, K. Egashira, S. Masuda, K. Funakoshi, G. Zhao, S. Kimura, T. Matoba, K. Sueishi, Y. Endo, Y. Kawashima, et al.
Formulation of Nanoparticle-Eluting Stents by a Cationic Electrodeposition Coating Technology: Efficient Nano-Drug Delivery via Bioabsorbable Polymeric Nanoparticle-Eluting Stents in Porcine Coronary Arteries
J. Am. Coll. Cardiol. Intv.,
April 1, 2009;
2(4):
277 - 283.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. Cyrus, H. Zhang, J. S. Allen, T. A. Williams, G. Hu, S. D. Caruthers, S. A. Wickline, and G. M. Lanza
Intramural Delivery of Rapamycin With {alpha}v{beta}3-Targeted Paramagnetic Nanoparticles Inhibits Stenosis After Balloon Injury
Arterioscler. Thromb. Vasc. Biol.,
May 1, 2008;
28(5):
820 - 826.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. Ohtani, K. Egashira, K. Nakano, G. Zhao, K. Funakoshi, Y. Ihara, S. Kimura, R. Tominaga, R. Morishita, and K. Sunagawa
Stent-Based Local Delivery of Nuclear Factor-{kappa}B Decoy Attenuates In-Stent Restenosis in Hypercholesterolemic Rabbits
Circulation,
December 19, 2006;
114(25):
2773 - 2779.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
W. Yang, J. Ge, H. Liu, K. Zhao, X. Liu, X. Qu, W. Li, Y. Huang, A. Sun, and Y. Zou
Arsenic trioxide eluting stent reduces neointima formation in a rabbit iliac artery injury model
Cardiovasc Res,
December 1, 2006;
72(3):
483 - 493.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
N. M.M. Pires, A. Schepers, B. L. van der Hoeven, M. R. de Vries, L. S.M. Boesten, J. W. Jukema, and P. H.A. Quax
Histopathologic alterations following local delivery of dexamethasone to inhibit restenosis in murine arteries
Cardiovasc Res,
December 1, 2005;
68(3):
415 - 424.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Kondyurin, V. Romanova, V. Begishev, I. Kondyurina, R. Guenzel, and M. F. Maitz
Crosslinked Polyurethane Coating on Vascular Stents for Enhanced X-ray Contrast
Journal of Bioactive and Compatible Polymers,
January 1, 2005;
20(1):
77 - 93.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
R. S. Schwartz, N. A. Chronos, and R. Virmani
Preclinical restenosis models and drug-eluting stents: Still important, still much to learn
J. Am. Coll. Cardiol.,
October 6, 2004;
44(7):
1373 - 1385.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
F. Vogt, A. Stein, G. Rettemeier, N. Krott, R. Hoffmann, J. v. Dahl, A.-K. Bosserhoff, W. Michaeli, P. Hanrath, C. Weber, et al.
Long-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent
Eur. Heart J.,
August 1, 2004;
25(15):
1330 - 1340.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
B. Meng, X. H. Wang, F. Z. Cui, H. Y. Dong, and F. Yu
A New Method of Heparinizing PLLA Film by Surface Entrapment
Journal of Bioactive and Compatible Polymers,
March 1, 2004;
19(2):
131 - 143.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
Y. S. Do, E. Y. Kao, F. Ganaha, H. Minamiguchi, K. Sugimoto, J. Lee, C. J. Elkins, P. G. Amabile, M. D. Kuo, D. S. Wang, et al.
In-Stent Restenosis Limitation with Stent-based Controlled-Release Nitric Oxide: Initial Results in Rabbits
Radiology,
February 1, 2004;
230(2):
377 - 382.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. Schurmann, J. Lahann, P. Niggemann, B. Klosterhalfen, J. Meyer, A. Kulisch, D. Klee, R. W. Gunther, and D. Vorwerk
Biologic Response to Polymer-coated Stents: In Vitro Analysis and Results in an Iliac Artery Sheep Model
Radiology,
January 1, 2004;
230(1):
151 - 162.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
B Heublein, R Rohde, V Kaese, M Niemeyer, W Hartung, and A Haverich
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heart,
June 1, 2003;
89(6):
651 - 656.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. E. Sousa, P. W. Serruys, and M. A. Costa
New Frontiers in Cardiology: Drug-Eluting Stents: Part I
Circulation,
May 6, 2003;
107(17):
2274 - 2279.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. M. Lanza, X. Yu, P. M. Winter, D. R. Abendschein, K. K. Karukstis, M. J. Scott, L. K. Chinen, R. W. Fuhrhop, D. E. Scherrer, and S. A. Wickline
Targeted Antiproliferative Drug Delivery to Vascular Smooth Muscle Cells With a Magnetic Resonance Imaging Nanoparticle Contrast Agent: Implications for Rational Therapy of Restenosis
Circulation,
November 26, 2002;
106(22):
2842 - 2847.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. N. Babapulle and M. J. Eisenberg
Coated Stents for the Prevention of Restenosis: Part I
Circulation,
November 19, 2002;
106(21):
2734 - 2740.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M Peuster, P Wohlsein, M Brugmann, M Ehlerding, K Seidler, C Fink, H Brauer, A Fischer, and G Hausdorf
A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal---results 6-18 months after implantation into New Zealand white rabbits
Heart,
November 1, 2001;
86(5):
563 - 569.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
E Regar, G Sianos, and P W Serruys
Stent development and local drug delivery
Br. Med. Bull.,
October 1, 2001;
59(1):
227 - 248.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
C.-W. Hwang, D. Wu, and E. R. Edelman
Physiological Transport Forces Govern Drug Distribution for Stent-Based Delivery
Circulation,
July 31, 2001;
104(5):
600 - 605.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. E. Drachman, E. R. Edelman, P. Seifert, A. R. Groothuis, D. A. Bornstein, K. R. Kamath, M. Palasis, D. Yang, S. H. Nott, and C. Rogers
Neointimal thickening after stent delivery of paclitaxel: change in composition and arrest of growth over six months
J. Am. Coll. Cardiol.,
December 1, 2000;
36(7):
2325 - 2332.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Colombo and E. Karvouni
Biodegradable Stents : "Fulfilling the Mission and Stepping Away"
Circulation,
July 25, 2000;
102(4):
371 - 373.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. Tamai, K. Igaki, E. Kyo, K. Kosuga, A. Kawashima, S. Matsui, H. Komori, T. Tsuji, S. Motohara, and H. Uehata
Initial and 6-Month Results of Biodegradable Poly-l-Lactic Acid Coronary Stents in Humans
Circulation,
July 25, 2000;
102(4):
399 - 404.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. S Ettenson and E. R Edelman
Local drug delivery: an emerging approach in the treatment of restenosis
Vascular Medicine,
May 1, 2000;
5(2):
97 - 102.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
E. Alt, I. Haehnel, C. Beilharz, K. Prietzel, D. Preter, A. Stemberger, T. Fliedner, W. Erhardt, and A. Schomig
Inhibition of Neointima Formation After Experimental Coronary Artery Stenting : A New Biodegradable Stent Coating Releasing Hirudin and the Prostacyclin Analogue Iloprost
Circulation,
March 28, 2000;
101(12):
1453 - 1458.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. G. Lehmann, J. J. Popma, J. A. Werner, A. J. Lansky, and R. L. Wilensky
Vascular remodeling and the local delivery of cytochalasin B after coronary angioplasty in humans
J. Am. Coll. Cardiol.,
March 1, 2000;
35(3):
583 - 591.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D M Whelan, W J van der Giessen, S C Krabbendam, E A van Vliet, P D Verdouw, P W Serruys, and H M M van Beusekom
Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries
Heart,
March 1, 2000;
83(3):
338 - 345.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
J Gunn and D Cumberland
Stent coatings and local drug delivery. State of the art
Eur. Heart J.,
December 1, 1999;
20(23):
1693 - 1700.
[PDF]
|
 |
|

|
 |

|
 |
 
P. J. Bray, B. Du, V. M. Mejia, S. C. Hao, E. Deutsch, C. Fu, R. C. Wilson, H. Hanauske-Abel, and T. A. McCaffrey
Glucocorticoid Resistance Caused by Reduced Expression of the Glucocorticoid Receptor in Cells From Human Vascular Lesions
Arterioscler. Thromb. Vasc. Biol.,
May 1, 1999;
19(5):
1180 - 1189.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
O. F. Bertrand, R. Sipehia, R. Mongrain, J. Rodes, J.-C. Tardif, L. Bilodeau, G. Cote, and M. G. Bourassa
Biocompatibility aspects of new stent technology
J. Am. Coll. Cardiol.,
September 1, 1998;
32(3):
562 - 571.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. Yamawaki, H. Shimokawa, T. Kozai, K. Miyata, T. Higo, E. Tanaka, K. Egashira, T. Shiraishi, H. Tamai, K. Igaki, et al.
Intramural delivery of a specific tyrosine kinase inhibitor with biodegradable stent suppresses the restenotic changes of the coronary artery in pigs in vivo
J. Am. Coll. Cardiol.,
September 1, 1998;
32(3):
780 - 786.
[Abstract]
[Full Text]
[PDF]
|
 |
|
|