JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1997; 29:734-740
© 1997 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rishi, F
Right arrow Articles by Campbell, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rishi, F
Right arrow Articles by Campbell, R.

Effects of dual-chamber pacing for pediatric patients with hypertrophic obstructive cardiomyopathy

F Rishi, JE Hulse, DO Auld, G McRae, J Kaltman, K Kanter, W Williams, and RM Campbell

Children's Heart Center, Egleston Children's Hospital, Emory University, Atlanta, Georgia 30328, USA.

OBJECTIVES: The effects of both temporary and permanent dual-chamber pacing (DCP) were evaluated in symptomatic pediatric patients with hypertrophic obstructive cardiomyopathy (HOCM) unresponsive to medications. BACKGROUND: Permanent DCP pacing can reduce left ventricular outflow tract (LVOT) gradient and relieve symptoms in adult patients with HOCM. METHODS: Ten patients (mean [+/-SD] age 11.1 +/- 6 years, range 1 to 17.5) with HOCM and a Doppler LVOT gradient > or = 40 mm Hg were studied. The seven patients showing hemodynamic improvement during temporary pacing at cardiac catheterization underwent surgical implantation of a permanent DCP system. The effects of permanent pacing were evaluated using a questionnaire, Doppler evaluation, treadmill testing and repeat cardiac catheterization. RESULTS: At initial cardiac catheterization, three patients failed to respond to temporary pacing (inadequate pace capture in two; congenital mitral valve abnormality in one). The remaining seven patients (70%, 95% confidence interval 38.0% to 91.7%, mean age 13 +/- years, range 4 to 17.5) showed a significant reduction (p < 0.05) in LVOT gradient, left ventricular systolic pressure and pulmonary capillary wedge pressure. After pacemaker implantation, these seven patients reported a significant reduction in dyspnea on exertion and exercise intolerance. Serial Doppler evaluation showed a significant reduction in LVOT gradient. Follow-up catheterization at 23 +/- 4 months in six patients (one patient declined restudy) showed a persistent decrease in LVOT gradient (53 +/- 13 vs. 16 +/- 11 mm Hg), left ventricular systolic pressure (149 +/- 16 vs. 108 +/- 14 mm Hg) and pulmonary capillary wedge pressure (18 +/- 2 vs. 12 +/- 4 mm Hg) versus preimplantation values. CONCLUSIONS: Permanent DCP is an effective therapy for selected pediatric patients with HOCM. Rapid atrial rates and intrinsic atrioventricular conduction, as well as congenital mitral valve abnormalities, may preclude effective pacing in certain patients.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
A. E. Epstein, J. P. DiMarco, K. A. Ellenbogen, N.A. M. Estes III, R. A. Freedman, L. S. Gettes, A. M. Gillinov, G. Gregoratos, S. C. Hammill, D. L. Hayes, et al.
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) Developed in Collaboration With the American Association for Thoracic Surgery and Society of Thoracic Surgeons
J. Am. Coll. Cardiol., May 27, 2008; 51(21): e1 - e62.
[Full Text] [PDF]


Home page
CirculationHome page
A. E. Epstein, J. P. DiMarco, K. A. Ellenbogen, N.A. M. Estes III, R. A. Freedman, L. S. Gettes, A. M. Gillinov, G. Gregoratos, S. C. Hammill, D. L. Hayes, et al.
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): Developed in Collaboration With the American Association for Thoracic Surgery and Society of Thoracic Surgeons
Circulation, May 27, 2008; 117(21): e350 - e408.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
B. J. Maron, W. J. McKenna, G. K. Danielson, L. J. Kappenberger, H. J. Kuhn, C. E. Seidman, P. M. Shah, W. H. Spencer III, P. Spirito, F. J. Ten Cate, et al.
American College of Cardiology/European Society of Cardiology Clinical Expert Consensus Document on Hypertrophic Cardiomyopathy: a report of the American College of Cardiology Foundation Task Force on Clinical Expert Consensus Documents and the European Society of Cardiology Committee for Practice Guidelines
J. Am. Coll. Cardiol., November 5, 2003; 42(9): 1687 - 1713.
[Full Text] [PDF]


Home page
Eur Heart JHome page
Writing Committee Members, B. J. Maron, W. J. McKenna, G. K. Danielson, L. J. Kappenberger, H. J. Kuhn, C. E. Seidman, P. M. Shah, W. H. Spencer III, P. Spirito, et al.
American College of Cardiology/European Society of Cardiology Clinical Expert Consensus Document on Hypertrophic Cardiomyopathy: A report of the American College of Cardiology Foundation Task Force on Clinical Expert Consensus Documents and the European Society of Cardiology Committee for Practice Guidelines
Eur. Heart J., November 1, 2003; 24(21): 1965 - 1991.
[Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1997 by the American College of Cardiology Foundation.