Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1997; 29:21-27
© 1997 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nakamura, S
Right arrow Articles by Colombo, A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nakamura, S
Right arrow Articles by Colombo, A

High pressure assisted coronary stent implantation accomplished without intravascular ultrasound guidance and subsequent anticoagulation

S Nakamura, P Hall, A Gaglione, F Tiecco, M Di Maggio, L Maiello, G Martini, and A Colombo

Ohta General Hospital, Division of Cardiology, Japan.

OBJECTIVES: The purpose of this study was to determine the efficacy of treatment with antiplatelet therapy and no anticoagulation after high pressure assisted coronary stent implantation performed without intravascular ultrasound (IVUS) guidance. BACKGROUND: Previous studies have shown that during IVUS-guided Palmaz-Schatz coronary stenting, it is safe to withhold anticoagulation when stent expansion has been optimized by high pressure balloon dilation. METHODS: Patients that had successful coronary stenting without IVUS guidance were treated with ticlopidine, 500 mg/day, and aspirin, 325 mg/day, for 1 month and then received only aspirin, 325 mg/day, indefinitely. Patients were not treated with warfarin (Coumadin) or heparin after successful stenting. Clinical and angiographic events were assessed at 1 month. RESULTS: A total of 201 intracoronary stents were implanted in 127 patients with 137 lesions. The average number of stents per lesion was 1.4 +/- 0.8, and the average number of stents per patient was 1.6 +/- 1.1. Stent deployment was performed for elective indications in 79% of procedures and for emergency indications in 21%. There were four stent thrombosis events for a per patient event rate of 3.1% and a per lesion event rate of 2.9%. CONCLUSIONS: After high pressure assisted stenting performed without IVUS guidance, there was an acceptable incidence of 3.1% of stent thrombosis with the combination of short-term ticlopidine and aspirin therapy and no anticoagulation. Although the study involved only 127 patients, the results support the relative safety of stenting without IVUS guidance and with antiplatelet therapy only in comparison to historical trials on stenting performed with postprocedure anticoagulation.


This article has been cited by other articles:


Home page
CirculationHome page
K. Kolandaivelu, R. Swaminathan, W. J. Gibson, V. B. Kolachalama, K.-L. Nguyen-Ehrenreich, V. L. Giddings, L. Coleman, G. K. Wong, and E. R. Edelman
Stent Thrombogenicity Early in High-Risk Interventional Settings Is Driven by Stent Design and Deployment and Protected by Polymer-Drug Coatings
Circulation, April 5, 2011; 123(13): 1400 - 1409.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
P. Roy, D. H. Steinberg, S. J. Sushinsky, T. Okabe, T. L. Pinto Slottow, K. Kaneshige, Z. Xue, L. F. Satler, K. M. Kent, W. O. Suddath, et al.
The potential clinical utility of intravascular ultrasound guidance in patients undergoing percutaneous coronary intervention with drug-eluting stents
Eur. Heart J., August 1, 2008; 29(15): 1851 - 1857.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. O. Williams and J. D. Abbott
Et Tu, Bare Metal Stent?
Circulation, November 20, 2007; 116(21): 2363 - 2365.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. S. Schwartz, N. A. Chronos, and R. Virmani
Preclinical restenosis models and drug-eluting stents: Still important, still much to learn
J. Am. Coll. Cardiol., October 6, 2004; 44(7): 1373 - 1385.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. H. Wilson, P. Fasseas, J. L. Orford, R. J. Lennon, T. Horlocker, N. E. Charnoff, S. Melby, and P. B. Berger
Clinical outcome of patients undergoing non-cardiac surgery in the two months following coronary stenting
J. Am. Coll. Cardiol., July 16, 2003; 42(2): 234 - 240.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
E. Barbato, J. Marco, and W. Wijns
Direct stenting
Eur. Heart J., March 1, 2003; 24(5): 394 - 403.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
T. Takagi, G. Stankovic, L. Finci, K. Toutouzas, A. Chieffo, V. Spanos, F. Liistro, C. Briguori, N. Corvaja, R. Albero, et al.
Results and Long-Term Predictors of Adverse Clinical Events After Elective Percutaneous Interventions on Unprotected Left Main Coronary Artery
Circulation, August 6, 2002; 106(6): 698 - 702.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. L. Bhatt, M. E. Bertrand, P. B. Berger, P. L. L'Allier, I. Moussa, J. W. Moses, G. Dangas, M. Taniuchi, J. M. Lasala, D. R. Holmes, et al.
Meta-analysis of randomized and registry comparisons of ticlopidine with clopidogrel after stenting
J. Am. Coll. Cardiol., January 2, 2002; 39(1): 9 - 14.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
F. Schiele
Intravascular Ultrasound Guidance for Stent Implantation
Circulation, May 29, 2001; 103(21): e110 - e110.
[Full Text] [PDF]


Home page
CirculationHome page
J. Dirschinger, A. Kastrati, F.-J. Neumann, P. Boekstegers, S. Elezi, J. Mehilli, H. Schuhlen, J. Pache, E. Alt, R. Blasini, et al.
Influence of Balloon Pressure During Stent Placement in Native Coronary Arteries on Early and Late Angiographic and Clinical Outcome : A Randomized Evaluation of High-Pressure Inflation
Circulation, August 31, 1999; 100(9): 918 - 923.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. E. E. Hanekamp, J. J. Koolen, N. H. J. Pijls, H. R. Michels, and H. J. R. M. Bonnier
Comparison of Quantitative Coronary Angiography, Intravascular Ultrasound, and Coronary Pressure Measurement to Assess Optimum Stent Deployment
Circulation, March 2, 1999; 99(8): 1015 - 1021.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P. Urban, C. Macaya, H.-J. Rupprecht, F. Kiemeneij, H. Emanuelsson, A. Fontanelli, M. Pieper, T. Wesseling, L. Sagnard, and f. t. M. Investigators
Randomized Evaluation of Anticoagulation Versus Antiplatelet Therapy After Coronary Stent Implantation in High-Risk Patients : The Multicenter Aspirin and Ticlopidine Trial after Intracoronary Stenting (MATTIS)
Circulation, November 17, 1998; 98(20): 2126 - 2132.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. E. Bertrand, V. Legrand, J. Boland, E. Fleck, J. Bonnier, H. Emmanuelson, M. Vrolix, L. Missault, S. Chierchia, M. Casaccia, et al.
Randomized Multicenter Comparison of Conventional Anticoagulation Versus Antiplatelet Therapy in Unplanned and Elective Coronary Stenting : The Full Anticoagulation Versus Aspirin and Ticlopidine (FANTASTIC) Study
Circulation, October 20, 1998; 98(16): 1597 - 1603.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. Kastrati, F.-J. Neumann, and A. Schomig
Operator volume and outcome of patients undergoing coronary stent placement
J. Am. Coll. Cardiol., October 1, 1998; 32(4): 970 - 976.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
Y Yoshitomi, S Kojima, T Sugi, M Yano, Y Matsumoto, and M Kuramochi
Antiplatelet treatment with cilostazol after stent implantation
Heart, October 1, 1998; 80(4): 393 - 396.
[Abstract] [Full Text]


Home page
CirculationHome page
J. Bermejo, J. Botas, E. Garcia, J. Elizaga, J. Osende, J. Soriano, M. Abeytua, and J. L. Delcan
Mechanisms of Residual Lumen Stenosis After High-Pressure Stent Implantation : A Quantitative Coronary Angiography and Intravascular Ultrasound Study
Circulation, July 14, 1998; 98(2): 112 - 118.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. Rubartelli, L. Niccoli, E. Verna, C. Giachero, M. Zimarino, A. Fontanelli, C. Vassanelli, L. Campolo, E. Martuscelli, G. Tommasini, et al.
Stent implantation versus balloon angioplasty in chronic coronary occlusions: results from the GISSOC trial
J. Am. Coll. Cardiol., July 1, 1998; 32(1): 90 - 96.
[Abstract] [Full Text] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement