Second harmonic imaging of an intravenously administered echocardiographic contrast agent: Visualization of coronary arteries and measurement of coronary blood flow
SL Mulvagh,
DA Foley,
BC Aeschbacher,
KK Klarich,
and
JB Seward
Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic and Mayo Foundation, Rochester, Minnesota, 55905, USA.
OBJECTIVES: This study sought to evaluate the potential of second harmonic contrast echocardiography to assess coronary vasculature. BACKGROUND: Newer transpulmonary ultrasound contrast agents capable of resonance phenomena detected by harmonic imaging may theoretically be able to demonstrate blood flow in the myocardium. METHODS: Transthoracic B-mode images and Doppler were obtained using a prototype second harmonic ultrasound system after femoral vein injection of AF0145 (10 to 40 mg) in 13 closed chest dogs (mean weight 25.6 kg). Coronary Doppler flow was simultaneously invasively measured using an intracoronary flow wire and visually compared with transthoracic Doppler flow. "Noninvasive" coronary vasodilator reserve was determined by measuring the ratio of the Doppler time velocity integral after adenosine to the baseline value and compared with the "invasive" intracoronary determination. RESULTS: Harmonic imaging showed heterogeneous opacification of the myocardium characterized by linear branching structures consistent with intramyocardial coronary arteries, which were not clearly visible during conventional ultrasound imaging. In nine dogs, transthoracic Doppler was performed, and characteristic coronary Doppler flow was observed, identical to the simultaneously observed intracoronary Doppler flow. Intracoronary adenosine (120 to 150 microgram) equally increased intracoronary and transthoracic Doppler flow velocities. The calculated "noninvasive" and "invasive" coronary vasodilator reserve ratios were similar ([mean +/- SD] 3.3 +/- 1.0 and 3.6 +/- 1.2, p = NS), with excellent correlation (r = 0.95, p = 0.0012). CONCLUSIONS: These findings indicate that noninvasive assessment of intramyocardial coronary vasculature and measurement of coronary blood flow reserve are possible using second harmonic contrast echocardiography.
This article has been cited by other articles:

|
 |

|
 |
 
D. Platts, C. West, T. Boga, C. Hamilton-Craig, and D. Burstow
Direct visualization of septal perforator coronary arterial blood flow during perflutren microsphere contrast echocardiography
Eur J Echocardiogr,
August 1, 2009;
10(6):
808 - 810.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
S. Masroor
Invited commentary.
Ann. Thorac. Surg.,
March 1, 2009;
87(3):
719 - 719.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. L. Miller, M. A. Averkiou, A. A. Brayman, E. C. Everbach, C. K. Holland, J. H. Wible Jr, and J. Wu
Bioeffects Considerations for Diagnostic Ultrasound Contrast Agents
J. Ultrasound Med.,
April 1, 2008;
27(4):
611 - 632.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. A Abdel Aziz, P. Kumar, N. Bazargani, E. Al-Hato, and N. Al Khaja
Assessment of Coronary Bypass Graft Patency by Electron-Beam Computed Tomography
Asian Cardiovasc Thorac Ann,
June 1, 2003;
11(2):
102 - 106.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Spinazzi
Emerging clinical applications for contrast echocardiography
Eur. Heart J. Suppl.,
March 1, 2002;
4(suppl_C):
C8 - C11.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
F. S. Villanueva, E. W. Gertz, M. Csikari, G. Pulido, D. Fisher, and J. Sklenar
Detection of Coronary Artery Stenosis With Power Doppler Imaging
Circulation,
May 29, 2001;
103(21):
2624 - 2630.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. D. Mills, D. Fischer, and F. S. Villanueva
Coronary collateral development during chronic ischemia: serial assessment using harmonic myocardial contrast echocardiography
J. Am. Coll. Cardiol.,
August 1, 2000;
36(2):
618 - 624.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. Voci
The bubbles and the science of life
J. Am. Coll. Cardiol.,
August 1, 2000;
36(2):
625 - 627.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J Hancock, H Dittrich, D E Jewitt, and M J Monaghan
Evaluation of myocardial, hepatic, and renal perfusion in a variety of clinical conditions using an intravenous ultrasound contrast agent (Optison) and second harmonic imaging
Heart,
June 1, 1999;
81(6):
636 - 641.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
S. Achenbach, W. Moshage, D. Ropers, J. Nossen, and W. G. Daniel
Value of Electron-Beam Computed Tomography for the Noninvasive Detection of High-Grade Coronary-Artery Stenoses and Occlusions
N. Engl. J. Med.,
December 31, 1998;
339(27):
1964 - 1971.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. C. Wu, R. J. Kim, D. A. Bluemke, C. E. Rochitte, E. A. Zerhouni, L. C. Becker, and J. A. C. Lima
Quantification and time course of microvascular obstruction by contrast-enhanced echocardiography and magnetic resonance imaging following acute myocardial infarction and reperfusion
J. Am. Coll. Cardiol.,
November 15, 1998;
32(6):
1756 - 1764.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. Hozumi, K. Yoshida, T. Akasaka, Y. Asami, Y. Ogata, T. Takagi, S. Kaji, T. Kawamoto, Y. Ueda, and S. Morioka
Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography: Comparison with invasive technique
J. Am. Coll. Cardiol.,
November 1, 1998;
32(5):
1251 - 1259.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. D. Kasprzak, W. B. Vletter, J. R.T.C. Roelandt, J. R. van Meegen, R. Johnson, and F. J. Ten Cate
Visualization and quantification of myocardial mass at risk using three-dimensional contrast echocardiography
Cardiovasc Res,
November 1, 1998;
40(2):
314 - 321.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
L. Galiuto, A. N. DeMaria, K. May-Newman, U. del Balzo, K. Ohmori, V. Bhargava, S. F. Flaim, and S. Iliceto
Evaluation of dynamic changes in microvascular flow during ischemia-reperfusion by myocardial contrast echocardiography
J. Am. Coll. Cardiol.,
October 1, 1998;
32(4):
1096 - 1101.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. Postert, A. Muhs, S. Meves, J. Federlein, H. Przuntek, and T. Buttner
Transient Response Harmonic Imaging : An Ultrasound Technique Related to Brain Perfusion
Stroke,
September 1, 1998;
29(9):
1901 - 1907.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. Wei, A. R. Jayaweera, S. Firoozan, A. Linka, D. M. Skyba, and S. Kaul
Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion?
J. Am. Coll. Cardiol.,
July 1, 1998;
32(1):
252 - 260.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. Seidel and M. Kaps
Harmonic Imaging of the Vertebrobasilar System
Stroke,
August 1, 1997;
28(8):
1610 - 1613.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
F. Forsberg, C. W. Piccoli, J.-B. Liu, N. M. Rawool, D. A. Merton, D. G. Mitchell, and B. B. Goldberg
Hepatic Tumor Detection: MR Imaging and Conventional US versus Pulse-Inversion Harmonic US of NC100100 during Its Reticuloendothelial System-Specific Phase
Radiology,
March 1, 2002;
222(3):
824 - 829.
[Abstract]
[Full Text]
[PDF]
|
 |
|
|