JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1996; 27:1519-1525
© 1996 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mulvagh, S.
Right arrow Articles by Seward, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mulvagh, S.
Right arrow Articles by Seward, J.

Second harmonic imaging of an intravenously administered echocardiographic contrast agent: Visualization of coronary arteries and measurement of coronary blood flow

SL Mulvagh, DA Foley, BC Aeschbacher, KK Klarich, and JB Seward

Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic and Mayo Foundation, Rochester, Minnesota, 55905, USA.

OBJECTIVES: This study sought to evaluate the potential of second harmonic contrast echocardiography to assess coronary vasculature. BACKGROUND: Newer transpulmonary ultrasound contrast agents capable of resonance phenomena detected by harmonic imaging may theoretically be able to demonstrate blood flow in the myocardium. METHODS: Transthoracic B-mode images and Doppler were obtained using a prototype second harmonic ultrasound system after femoral vein injection of AF0145 (10 to 40 mg) in 13 closed chest dogs (mean weight 25.6 kg). Coronary Doppler flow was simultaneously invasively measured using an intracoronary flow wire and visually compared with transthoracic Doppler flow. "Noninvasive" coronary vasodilator reserve was determined by measuring the ratio of the Doppler time velocity integral after adenosine to the baseline value and compared with the "invasive" intracoronary determination. RESULTS: Harmonic imaging showed heterogeneous opacification of the myocardium characterized by linear branching structures consistent with intramyocardial coronary arteries, which were not clearly visible during conventional ultrasound imaging. In nine dogs, transthoracic Doppler was performed, and characteristic coronary Doppler flow was observed, identical to the simultaneously observed intracoronary Doppler flow. Intracoronary adenosine (120 to 150 microgram) equally increased intracoronary and transthoracic Doppler flow velocities. The calculated "noninvasive" and "invasive" coronary vasodilator reserve ratios were similar ([mean +/- SD] 3.3 +/- 1.0 and 3.6 +/- 1.2, p = NS), with excellent correlation (r = 0.95, p = 0.0012). CONCLUSIONS: These findings indicate that noninvasive assessment of intramyocardial coronary vasculature and measurement of coronary blood flow reserve are possible using second harmonic contrast echocardiography.


This article has been cited by other articles:


Home page
J Ultrasound MedHome page
D. L. Miller, M. A. Averkiou, A. A. Brayman, E. C. Everbach, C. K. Holland, J. H. Wible Jr, and J. Wu
Bioeffects Considerations for Diagnostic Ultrasound Contrast Agents
J. Ultrasound Med., April 1, 2008; 27(4): 611 - 632.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
T. A Abdel Aziz, P. Kumar, N. Bazargani, E. Al-Hato, and N. Al Khaja
Assessment of Coronary Bypass Graft Patency by Electron-Beam Computed Tomography
Asian Cardiovasc Thorac Ann, June 1, 2003; 11(2): 102 - 106.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J SupplHome page
A. Spinazzi
Emerging clinical applications for contrast echocardiography
Eur. Heart J. Suppl., March 1, 2002; 4(suppl_C): C8 - C11.
[Abstract] [PDF]


Home page
CirculationHome page
F. S. Villanueva, E. W. Gertz, M. Csikari, G. Pulido, D. Fisher, and J. Sklenar
Detection of Coronary Artery Stenosis With Power Doppler Imaging
Circulation, May 29, 2001; 103(21): 2624 - 2630.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. D. Mills, D. Fischer, and F. S. Villanueva
Coronary collateral development during chronic ischemia: serial assessment using harmonic myocardial contrast echocardiography
J. Am. Coll. Cardiol., August 1, 2000; 36(2): 618 - 624.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. Voci
The bubbles and the science of life
J. Am. Coll. Cardiol., August 1, 2000; 36(2): 625 - 627.
[Full Text] [PDF]


Home page
HeartHome page
J Hancock, H Dittrich, D E Jewitt, and M J Monaghan
Evaluation of myocardial, hepatic, and renal perfusion in a variety of clinical conditions using an intravenous ultrasound contrast agent (Optison) and second harmonic imaging
Heart, June 1, 1999; 81(6): 636 - 641.
[Abstract] [Full Text]


Home page
NEJMHome page
S. Achenbach, W. Moshage, D. Ropers, J. Nossen, and W. G. Daniel
Value of Electron-Beam Computed Tomography for the Noninvasive Detection of High-Grade Coronary-Artery Stenoses and Occlusions
N. Engl. J. Med., December 31, 1998; 339(27): 1964 - 1971.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
K. C. Wu, R. J. Kim, D. A. Bluemke, C. E. Rochitte, E. A. Zerhouni, L. C. Becker, and J. A. C. Lima
Quantification and time course of microvascular obstruction by contrast-enhanced echocardiography and magnetic resonance imaging following acute myocardial infarction and reperfusion
J. Am. Coll. Cardiol., November 15, 1998; 32(6): 1756 - 1764.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. Hozumi, K. Yoshida, T. Akasaka, Y. Asami, Y. Ogata, T. Takagi, S. Kaji, T. Kawamoto, Y. Ueda, and S. Morioka
Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography: Comparison with invasive technique
J. Am. Coll. Cardiol., November 1, 1998; 32(5): 1251 - 1259.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
J. D. Kasprzak, W. B. Vletter, J. R.T.C. Roelandt, J. R. van Meegen, R. Johnson, and F. J. Ten Cate
Visualization and quantification of myocardial mass at risk using three-dimensional contrast echocardiography
Cardiovasc Res, November 1, 1998; 40(2): 314 - 321.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
L. Galiuto, A. N. DeMaria, K. May-Newman, U. del Balzo, K. Ohmori, V. Bhargava, S. F. Flaim, and S. Iliceto
Evaluation of dynamic changes in microvascular flow during ischemia-reperfusion by myocardial contrast echocardiography
J. Am. Coll. Cardiol., October 1, 1998; 32(4): 1096 - 1101.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
T. Postert, A. Muhs, S. Meves, J. Federlein, H. Przuntek, and T. Buttner
Transient Response Harmonic Imaging : An Ultrasound Technique Related to Brain Perfusion
Stroke, September 1, 1998; 29(9): 1901 - 1907.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
K. Wei, A. R. Jayaweera, S. Firoozan, A. Linka, D. M. Skyba, and S. Kaul
Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion?
J. Am. Coll. Cardiol., July 1, 1998; 32(1): 252 - 260.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
G. Seidel and M. Kaps
Harmonic Imaging of the Vertebrobasilar System
Stroke, August 1, 1997; 28(8): 1610 - 1613.
[Abstract] [Full Text]


Home page
RadiologyHome page
F. Forsberg, C. W. Piccoli, J.-B. Liu, N. M. Rawool, D. A. Merton, D. G. Mitchell, and B. B. Goldberg
Hepatic Tumor Detection: MR Imaging and Conventional US versus Pulse-Inversion Harmonic US of NC100100 during Its Reticuloendothelial System-Specific Phase
Radiology, March 1, 2002; 222(3): 824 - 829.
[Abstract] [Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1996 by the American College of Cardiology Foundation.