Advertisement






Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1996; 27:1497-1501
© 1996 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Porter, T.
Right arrow Articles by Armbruster, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Porter, T.
Right arrow Articles by Armbruster, R.

Improved myocardial contrast with second harmonic transient ultrasound response imaging in humans using intravenous perfluorocarbon-exposed sonicated dextrose albumin

TR Porter, F Xie, D Kricsfeld, and RW Armbruster

University of Nebraska Medical Center, Omaha 68198-2265, USA.

OBJECTIVES: The objectives of this study were to determine whether a new method of ultrasound imaging (transient response imaging) could improve the myocardial contrast after intravenous injections of perfluorocarbon-exposed sonicated dextrose albumin microbubble contrast medium in humans. BACKGROUND: We have shown in animals that very low doses of intravenous contrast medium can produce transient but significantly better myocardial contrast when diagnostic ultrasound pulses are interrupted (delivered only once per cardiac cycle) instead of conventional 25- to 30-Hz frame rate imaging. METHODS: In 14 patients with normal rest wall motion, the peak myocardial contrast produced by transient response imaging was compared with that produced by conventional harmonic ultrasound imaging after injections of low doses (0.0025 to 0.01 ml/kg) of intravenous contrast medium. All studies were performed with second harmonic imaging (2.0 to 2.5 MHz-transmitted frequency). Blood pressure, oxygen saturation, respiratory rate and pulse were monitored before and after each injection. RESULTS: The intravenous contrast medium in the doses given produced no hemodynamic changes and no significant side effects in any patients. Overall, the mean (+/-SD) anterior and posterior myocardial contrast produced was significantly greater with transient response imaging than with conventional harmonic ultrasound imaging (anterior: 37 +/- 20 U transient response imaging vs. 18 +/- 14 U conventional harmonic imaging; posterior: 17 +/- 14 U transient response imaging vs. 5 +/- 5 U conventional; p< 0.01). With the sample size of 14 patients, the study had 80% power to detect a true difference of 18 U for anterior myocardial contrast and 90% power to detect a difference of 12 U for posterior contrast. Visually evident anterior or apical myocardial contrast was observed in 14 of 15 patients with transient response imaging but in only 7 patients with conventional harmonic imaging. Posterior or basal myocardial contrast was evident in 10 patients with transient response imaging but in only 1 patient with conventional harmonic imaging. CONCLUSIONS: Transient response imaging produces significantly better myocardial contrast than conventional harmonic imaging in humans and can be produced safely with minute quantities of intravenous perfluorocarbon.


This article has been cited by other articles:


Home page
J Ultrasound MedHome page
D. L. Miller, M. A. Averkiou, A. A. Brayman, E. C. Everbach, C. K. Holland, J. H. Wible Jr, and J. Wu
Bioeffects Considerations for Diagnostic Ultrasound Contrast Agents
J. Ultrasound Med., April 1, 2008; 27(4): 611 - 632.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
D Cosgrove
Developments in ultrasound
Imaging, June 1, 2006; 18(2): 82 - 96.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. M. Tsutsui, F. Xie, M. Cano, J. Chomas, P. Phillips, S. J. Radio, J. Lof, and T. R. Porter
Detection of retained microbubbles in carotid arteries with real-time low mechanical index imaging in the setting of endothelial dysfunction
J. Am. Coll. Cardiol., September 1, 2004; 44(5): 1036 - 1046.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
B Cosyns, P El Haddad, H Lignian, C Daniels, C Weytjens, D Schoors, and G Van Camp
Contrast harmonic imaging improves the evaluation of left ventricular function in ventilated patients: comparison with transesophageal echocardiography
Eur J Echocardiogr, March 1, 2004; 5(2): 118 - 122.
[Abstract] [Full Text] [PDF]


Home page
ANGIOLOGYHome page
M. Nishino, H.-J. Youn, D. Gheorghevici, C. Zellner, T. M. Chou, K. Sudhir, and R. F. Redberg
Effect of Intracoronary Estradiol on Postischemic Microvascular Damage in a Porcine Model: A Myocardial Contrast Echocardiographic Study
Angiology, November 1, 2003; 54(6): 701 - 709.
[Abstract] [PDF]


Home page
J Ultrasound MedHome page
H. Maruyama, S. Matsutani, H. Saisho, Y. Mine, H. Yuki, and K. Miyata
Extra-Low Acoustic Power Harmonic Images of the Liver With Perflutren: Novel Imaging for Real-Time Observation of Liver Perfusion
J. Ultrasound Med., September 1, 2003; 22(9): 931 - 938.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
J. U. Harrer and C. Klotzsch
Second Harmonic Imaging of the Human Brain: The Practicability of Coronal Insonation Planes and Alternative Perfusion Parameters
Stroke, June 1, 2002; 33(6): 1530 - 1535.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
T. Asanuma, K. Viggen, J. B. Seward, and M. Belohlavek
Dual-Spectra Ultrasonography: An Attenuation-Compensating Technique for Myocardial Perfusion Analysis
J. Ultrasound Med., March 1, 2002; 21(3): 249 - 259.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J SupplHome page
L. Agati, S. Funaro, M. Madonna, C. Volponi, G. Veneroso, and G. Tonti
Clinical utility of contrast echocardiography in the management of patients with acute myocardial infarction
Eur. Heart J. Suppl., March 1, 2002; 4(suppl_C): C27 - C34.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
T. R. Porter, F. Xie, M. Silver, D. Kricsfeld, and E. O'Leary
Real-time perfusion imaging with low mechanical index pulse inversion Doppler imaging
J. Am. Coll. Cardiol., March 1, 2001; 37(3): 748 - 753.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. D. Mills, D. Fischer, and F. S. Villanueva
Coronary collateral development during chronic ischemia: serial assessment using harmonic myocardial contrast echocardiography
J. Am. Coll. Cardiol., August 1, 2000; 36(2): 618 - 624.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. Mukherjee, J. Wong, B. Griffin, S. G. Ellis, T. Porter, S. Sen, and J. D. Thomas
Ten-fold augmentation of endothelial uptake of vascular endothelial growth factor with ultrasound after systemic administration
J. Am. Coll. Cardiol., May 1, 2000; 35(6): 1678 - 1686.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
I Jucquois, P Nihoyannopoulos, A-M D'Hondt, V Roelants, A Robert, J A Melin, D Glass, and J-L J Vanoverschelde
Comparison of myocardial contrast echocardiography with NC100100 and 99mTc sestamibi SPECT for detection of resting myocardial perfusion abnormalities in patients with previous myocardial infarction
Heart, May 1, 2000; 83(5): 518 - 524.
[Abstract] [Full Text]


Home page
RadiologyHome page
S. R. Wilson, P. N. Burns, D. Muradali, J. A. Wilson, and X. Lai
Harmonic Hepatic US with Microbubble Contrast Agent: Initial Experience Showing Improved Characterization of Hemangioma, Hepatocellular Carcinoma, and Metastasis
Radiology, April 1, 2000; 215(1): 153 - 161.
[Abstract] [Full Text]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. Scherrer-Crosbie, W. Steudel, R. Ullrich, P. R. Hunziker, N. Liel-Cohen, J. Newell, J. Zaroff, W. M. Zapol, and M. H. Picard
Echocardiographic determination of risk area size in a murine model of myocardial ischemia
Am J Physiol Heart Circ Physiol, September 1, 1999; 277(3): H986 - H992.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
F. Bilotta, L. Fiorani, E. Lendaro, S. Picardo, I. La Rosa, G. Rosa, and F. Fedele
Pulmonary Transit of Sonicated Albumin Microbubbles During Controlled Mechanical Ventilation: A Transthoracic Echocardiographic Study
Anesth. Analg., August 1, 1999; 89(2): 273 - 273.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
P. Colonna, R. Montisci, L. Galiuto, L. Meloni, and S. Iliceto
Effects of acute ischaemia on intramyocardial contraction heterogeneity; new ultrasound technologies to study an old phenomenon
Eur. Heart J., March 1, 1999; 20(5): 327 - 337.
[PDF]


Home page
J Am Coll CardiolHome page
K. C. Wu, R. J. Kim, D. A. Bluemke, C. E. Rochitte, E. A. Zerhouni, L. C. Becker, and J. A. C. Lima
Quantification and time course of microvascular obstruction by contrast-enhanced echocardiography and magnetic resonance imaging following acute myocardial infarction and reperfusion
J. Am. Coll. Cardiol., November 15, 1998; 32(6): 1756 - 1764.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
T. Postert, A. Muhs, S. Meves, J. Federlein, H. Przuntek, and T. Buttner
Transient Response Harmonic Imaging : An Ultrasound Technique Related to Brain Perfusion
Stroke, September 1, 1998; 29(9): 1901 - 1907.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
K. Wei, A. R. Jayaweera, S. Firoozan, A. Linka, D. M. Skyba, and S. Kaul
Quantification of Myocardial Blood Flow With Ultrasound-Induced Destruction of Microbubbles Administered as a Constant Venous Infusion
Circulation, February 10, 1998; 97(5): 473 - 483.
[Abstract] [Full Text] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement