|
|
||||||||||
|
J Am Coll Cardiol, 1996; 27:810-816 © 1996 by the American College of Cardiology Foundation |
Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School, Okayama, Japan.
OBJECTIVES. We sought to evaluate the effect of intraaortic balloon pumping on the phasic blood velocity waveform into myocardium with severe coronary artery stenosis. BACKGROUND. In the presence of severe coronary artery stenosis, it is not clear whether intraaortic balloon pumping augments intramyocardial inflow during diastole or changes systolic retrograde blood flow from the myocardium to the extramural coronary arteries. METHODS. Using anesthetized open chest dogs (n=7), we introduced severe stenosis in the left main coronary artery to reduce the poststenotic pressure to approximately 60 mm Hg (>90% diameter stenosis). Septal arterial blood flow velocities were measured with a 20-MHz, 80-channel ultrasound pulsed Doppler velocimeter. Left anterior descending arterial flow, aortic pressure and poststenotic distal coronary pressure were measured simultaneously. The diastolic anterograde flow integral and systolic retrograde flow integral were compared in the presence and absence of intraaortic balloon pumping. RESULTS. Although intraaortic balloon pumping augmented diastolic aortic pressure, this pressure increase was not effectively transmitted through stenosis. Septal arterial diastolic flow velocity was not augmented, and left anterior descending arterial flow was unchanged during intraaortic balloon pumping. CONCLUSIONS. In the presence of severe coronary artery stenosis, intraaortic balloon pumping failed to increase diastolic inflow in the myocardium and did not enhance systolic retrograde flow from the myocardium to the extramural coronary artery. Thus, the major effect of intraaortic balloon pumping on the ischemic heart with severe coronary artery stenosis may be achieved by reducing oxygen demand by systolic unloading.
This article has been cited by other articles:
![]() |
Y. Takami and H. Masumoto Effects of Intra-Aortic Balloon Pumping on Graft Flow in Coronary Surgery: An Intraoperative Transit-Time Flowmetric Study Ann. Thorac. Surg., September 1, 2008; 86(3): 823 - 827. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Ootaki, K. Kamohara, M. Akiyama, F. Zahr, M. W. Kopcak Jr., R. Dessoffy, and K. Fukamachi Phasic coronary blood flow pattern during a continuous flow left ventricular assist support Eur. J. Cardiothorac. Surg., November 1, 2005; 28(5): 711 - 716. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Dekker, K. Reesink, E. van der Veen, V. van Ommen, G. Geskes, C. Soemers, and J. Maessen Efficacy of a New Intraaortic Propeller Pump vs the Intraaortic Balloon Pump: An Animal Study Chest, June 1, 2003; 123(6): 2089 - 2095. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. G. Hundley, C. A. Hamilton, G. D. Clarke, L. D. Hillis, D. M. Herrington, R. A. Lange, R. J. Applegate, M. S. Thomas, J. Payne, K. M. Link, et al. Visualization and Functional Assessment of Proximal and Middle Left Anterior Descending Coronary Stenoses in Humans With Magnetic Resonance Imaging Circulation, June 29, 1999; 99(25): 3248 - 3254. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Deniz Kumbasar, E. Semiz, O. Sancaktar, S. Yalcinkaya, C. Ermis, and N. Deger Concomitant Use of Intraaortic Balloon Counterpulsation and Streptokinase in Acute Anterior Myocardial Infarction Angiology, June 1, 1999; 50(6): 465 - 471. [Abstract] [PDF] |
||||
![]() |
E. Toyota, M. Goto, H. Nakamoto, J. Ebata, H. Tachibana, O. Hiramatsu, Y. Ogasawara, and F. Kajiya Endothelium-derived nitric oxide enhances the effect of intraaortic balloon pumping on diastolic coronary flow Ann. Thorac. Surg., May 1, 1999; 67(5): 1254 - 1261. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Stefanadis, J. Dernellis, E. Tsiamis, C. Stratos, I. Kallikazaros, and P. Toutouzas AORTIC FUNCTION IN PATIENTS DURING INTRA-AORTIC BALLOON PUMPING DETERMINED BY THE PRESSURE-DIAMETER RELATION J. Thorac. Cardiovasc. Surg., December 1, 1998; 116(6): 1052 - 1059. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Gitter, C. M. Cate, K. Smart, and G. K. Jett Influence of Ascending Versus Descending Balloon Counterpulsation on Bypass Graft Blood Flow Ann. Thorac. Surg., February 1, 1998; 65(2): 365 - 370. [Abstract] [Full Text] [PDF] |
||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |