Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1996; 27:683-689
© 1996 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Morady, F
Right arrow Articles by Bogun, F
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Morady, F
Right arrow Articles by Bogun, F

Reasons for prolonged or failed attempts at radiofrequency catheter ablation of accessory pathways

F Morady, A Strickberger, KC Man, E Daoud, M Niebauer, R Goyal, M Harvey, and F Bogun

Division of Cardiology, Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor, Michigan 48109-0022, USA.

OBJECTIVES: The purpose of this study was to categorize the reasons for a prolonged or failed procedure in a series of patients undergoing catheter ablation of an accessory pathway. BACKGROUND: Radiofrequency ablation of accessory pathways at times requires a lengthy procedure or a second ablation session, or both, and not prior studies have systematically investigated the reasons for this. METHODS: In a consecutive series of 619 patients undergoing catheter ablation of an accessory pathway, the mean ablation time +/- SD was 68 +/- 64 min. The subjects of this study were 14 patients who had an ablation time >2 SD greater than the mean (>196 min) and 51 patients who required a second ablation session for a successful outcome. The accessory pathway in the 65 patients in this study was located in the right free wall in 19 patients (29%), septum in 14 (22%) and left free wall in 32 (49%). RESULTS: The primary reasons for a lengthy or failed ablation attempt were 1) inability to position the ablation catheter at the effective target site (16 patients, 25%); 2) instability of the ablation catheter or inadequate tissue contact at the target site, or both (15 patients, 23%); 3) mapping error due to an oblique course of the accessory pathway (7 patients, 11%); 4) failure to recognize a posteroseptal accessory pathway as being left-sided instead of right-sided (4 patients, 6%); 5) other errors in accessory pathway localization (6 patients, 9%); 6) epicardial location of the accessory pathway (5 patients, 8%); 7) recurrent atrial fibrillation (2 patients, 3%); 8) occurrence of a complication (2 patients, 3%); 9) unusual right-sided accessory pathway that inserted in the anterior right ventricle, 2 cm away from the lateral tricuspid annulus (1 patient, 1.5%); and 10) unexplained factors (7 patients, 11%). The most common effective strategies employed to achieve a successful outcome in these patients were 1) substitution of a more experienced operator; 2) use of ablation catheters of varying configurations; 3) switching from a retrograde aortic to a trans-septal approach; 4) switching from an inferior to a superior vena caval approach; 5) use of a 60-cm guiding sheath; 6) detailed mapping of the atrial or ventricular insertion of the accessory pathway; and 7) searching within the coronary sinus for a presumed accessory pathway potential. CONCLUSIONS: A lengthy or failed attempt at catheter ablation of an accessory pathway may be due to a variety of reasons, the most common of which are problems related to some aspect of catheter manipulation and errors in accessory pathway localization. Knowledge of the most common reasons for a lengthy or ineffective procedure may facilitate successful outcome of accessory pathway ablation.


This article has been cited by other articles:


Home page
EuropaceHome page
F. Sacher, M. Wright, U. B. Tedrow, M. D. O'Neill, P. Jais, M. Hocini, R. Macdonald, D. W. Davies, P. Kanagaratnam, N. Derval, et al.
Wolff-Parkinson-White ablation after a prior failure: a 7-year multicentre experience
Europace, June 1, 2010; 12(6): 835 - 841.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
E. Wissner, F. Ouyang, and K. H. Kuck
Examining the causes of ablation failure in the Wolff-Parkinson-White syndrome
Europace, June 1, 2010; 12(6): 772 - 773.
[Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
A. Chiribiri, S. Kelle, U. Kohler, L. F. Tops, B. Schnackenburg, R. Bonamini, J. J. Bax, E. Fleck, and E. Nagel
Magnetic resonance cardiac vein imaging: relation to mitral valve annulus and left circumflex coronary artery.
J. Am. Coll. Cardiol. Img., November 1, 2008; 1(6): 729 - 738.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
H. Nakagawa and W. M. Jackman
Catheter Ablation of Paroxysmal Supraventricular Tachycardia
Circulation, November 20, 2007; 116(21): 2465 - 2478.
[Full Text] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement