JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1996; 27:30-37
© 1996 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Komaru, T
Right arrow Articles by Tamaki, K
Right arrow Search for Related Content
PubMed
Right arrow Articles by Komaru, T
Right arrow Articles by Tamaki, K

Coronary angioplasty ameliorates hypoperfusion-induced endothelial dysfunction in patients with stable angina pectoris

T Komaru, S Isoyama, N Sekiguchi, K Akai, N Shiba, S Yasuda, M Funakoshi, K Shirato, M Zuguchi, E Nozaki, O Nishioka, and K Tamaki

First Department of Internal Medicine, Tohoku University School of Medicine, Sendai, Japan.

OBJECTIVES. This study sought to investigate the effect of coronary angioplasty on chronic hypoperfusion-induced endothelial dysfunction in patients with coronary heart disease. BACKGROUND. The endothelium is an important component for organ flow regulation. Ischemia with or without reperfusion is known to cause endothelial dysfunction. We tested the hypothesis that chronic hypoperfusion impairs endothelial function in the angiographically normal coronary artery segment distal to stenosis and that the impairment by chronic hypoperfusion is reduced by coronary angioplasty. METHODS. In 13 patients with stable angina pectoris, substance P (10, 30 and 100 pmol) and nitroglycerin (200 micrograms) were sequentially infused into the coronary artery in a cumulative manner on the day after coronary angioplasty. In 10 of these patients, vascular responses to these agents were again investigated 3 months after angioplasty. Changes in vascular diameter were evaluated in vessels located proximal and distal to the target lesion, both of which were angiographically normal, by performing computer-assisted quantitative coronary angiography. In five patients, the transstenotic pressure gradient was also measured with a pressure sensor-mounted guide wire before angioplasty. RESULTS. On the day after angioplasty, the magnitude of dilation by substance P in distal segments was significantly less than that in proximal segments and inversely correlated with the transstenotic pressure gradient (p < 0.05) and lesion stenosis (p < 0.05). There was no difference in nitroglycerin-induced vasodilation between the two vessel segment groups. Three months later, the impaired response to substance P in the distal segment was restored to normal. CONCLUSIONS. We conclude that chronic hypoperfusion impairs endothelium-dependent dilation of coronary artery distal to critical stenosis in patients with ischemic heart disease and that coronary angioplasty ameliorates the endothelial dysfunction within 3 months.





HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1996 by the American College of Cardiology Foundation.