|
|
||||||||||
|
J Am Coll Cardiol, 1996; 27:182-192 © 1996 by the American College of Cardiology Foundation |
Department of Thoracic and Cardiovascular Surgery, Skejby Sygehus, Aarhus University Hospital, Denmark.
OBJECTIVES. This study was designed to assess the accuracy of a new Doppler method for quantification of volumetric flow in vivo. BACKGROUND. Noninvasive assessment of volumetric flow through heart valves and the great vessels remains a clinical goal. We present a new method for quantification of volumetric flow based on color Doppler mapping that computes velocity vectors over a surface normal to the point of scanning. This Doppler technique assumes only the incompressibility of the fluid. The method is basically independent of the angle of incidence between the ultrasound beam and the direction of blood flow and includes variations of flow area. METHODS. The color Doppler method was tested in seven anesthetized pigs by measuring pulmonary volumetric flows using multiplane Doppler echocardiography. The results were compared with those obtained by the thermodilution technique. In addition, volumetric flows across the mitral valve were determined in 10 normal volunteers by transthoracic Doppler echocardiography and compared with flows obtained with velocity-encoded magnetic resonance imaging (MRI). RESULTS. The mean value of the differences between the thermodilution technique and color Doppler were -0.16 +/- 0.94 liter/min for pulmonary volumetric flows (mean value of differences for [Thermodilution-Color Doppler] +/- 2 SD of differences). The mean value of the differences between MRI and color Doppler were 0.21 +/- 0.83 liter/min for mitral valvular volumetric flows (mean value of differences for [MRI-Color Doppler] +/- 2 SD of differences). CONCLUSIONS. The method showed close agreement with thermodilution and MRI for assessment of volumetric flow in vivo. It is therefore a noninvasive method with potential applications for cardiac output measurement and for quantification of volumetric flow of valvular insufficiency and restrictive lesions.
This article has been cited by other articles:
![]() |
J. D. Thomas and Z. B. Popovic Assessment of Left Ventricular Function by Cardiac Ultrasound J. Am. Coll. Cardiol., November 21, 2006; 48(10): 2012 - 2025. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Mori, R. A. Rusk, M. Jones, X.-N. Li, T. Irvine, A. D. Zetts, and D. J. Sahn A new dynamic three-dimensional digital color doppler method for quantification of pulmonary regurgitation: validation study in an animal model J. Am. Coll. Cardiol., September 18, 2002; 40(6): 1179 - 1185. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y Ueda, T Hozumi, K Yoshida, H Watanabe, T Akasaka, T Takagi, A Yamamuro, S Homma, and J Yoshikawa Non-invasive automated assessment of the ratio of pulmonary to systemic flow in patients with atrial septal defects by the colour Doppler velocity profile integration method Heart, September 1, 2002; 88(3): 278 - 282. [Abstract] [Full Text] [PDF] |
||||
![]() |
W Y Kim, P Søgaard, P T Mortensen, H K. Jensen, A K. Pedersen, B O Kristensen, and H Egeblad Three dimensional echocardiography documents haemodynamic improvement by biventricular pacing in patients with severe heart failure Heart, May 1, 2001; 85(5): 514 - 520. [Abstract] [Full Text] |
||||
![]() |
Y. Mori, T. Irvine, M. Jones, R. A. Rusk, Q. Pham, A. Kenny, and D. J. Sahn Validation of a digital color Doppler flow measurement method for pulmonary regurgitant volumes and regurgitant fractions in an in vitro model and in a chronic animal model of postoperative repaired tetralogy of Fallot J. Am. Coll. Cardiol., February 1, 2001; 37(2): 632 - 640. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Shiota, M. Jones, S. Aida, M. Chikada, H. Tsujino, T. El-Kadi, and D. J. Sahn Validation of the accuracy of both right and left ventricular outflow volume determinations and semiautomated calculation of shunt volumes through atrial septal defects by digital color Doppler flow mapping in a chronic animal model J. Am. Coll. Cardiol., August 1, 1999; 34(2): 587 - 593. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. A. McCullough, W. W. O'Neill, M. Graham, R. J. Stomel, F. Rogers, S. David, A. Farhat, R. Kazlauskaite, M. Al-Zagoum, and C. L. Grines A prospective randomized trial of triage angiography in acute coronary syndromes ineligible for thrombolytic therapy: Results of the medicine versus angiography in thrombolytic exclusion (MATE) trial J. Am. Coll. Cardiol., September 1, 1998; 32(3): 596 - 605. [Abstract] [Full Text] [PDF] |
||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |