JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1995; 26:939-946
© 1995 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Strikwerda, S
Right arrow Articles by Serruys, P.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Strikwerda, S
Right arrow Articles by Serruys, P.

Immediate and late outcome of excimer laser and balloon coronary angioplasty: a quantitative angiographic comparison based on matched lesions

S Strikwerda, E Montauban van Swijndregt, DP Foley, E Boersma, VA Umans, R Melkert, and PW Serruys

Cardiac Catheterization Laboratory, Thoraxcenter, University Hospital Dijkzigt, Erasmus University, Rotterdam, The Netherlands.

OBJECTIVES. This study sought to compare acute lumen changes and late lumen narrowing during and after excimer laser-assisted balloon angioplasty, measured by quantitative coronary angiography, with the immediate and long-term outcome of balloon angioplasty alone. BACKGROUND. Although excimer laser coronary angioplasty is used as an adjunct or alternative to balloon angioplasty, limited comparative data exist regarding the immediate and long-term efficacy of excimer laser-assisted balloon angioplasty versus balloon angioplasty alone. METHODS. A series of 53 lesions in 47 consecutive patients successfully treated with excimer laser-assisted balloon angioplasty were individually matched after completion of 6-month follow-up angiography with 53 successfully treated balloon angioplasty lesions according to vessel location, preprocedural minimal lumen diameter and reference diameter. Immediate and long-term angiographic results were assessed by an automated lumen contour detection algorithm. RESULTS. Before intervention in the laser and balloon angioplasty groups, respectively, minimal lumen diameter (mean +/- SD) was 0.73 +/- 0.47 and 0.74 +/- 0.46 mm, and reference diameter was 2.71 +/- 0.42 and 2.72 +/- 0.41 mm. Laser angioplasty was followed by adjunctive balloon dilation in 50 lesions. Mean balloon diameter at maximal inflation was similar in both treatment groups (2.61 +/- 0.32 and 2.65 +/- 0.38 mm, respectively), resulting in similar minimal lumen diameters after intervention of 1.77 +/- 0.41 and 1.78 +/- 0.34 mm, respectively. At follow-up angiography, minimal lumen diameter after excimer laser-assisted balloon angioplasty was 1.17 +/- 0.63 mm, and that after balloon angioplasty alone was 1.46 +/- 0.67 mm (p = 0.02). The angiographic restenosis rates at follow-up using the 50% diameter stenosis cutoff criterion were 57% and 34%, respectively (p = 0.02). CONCLUSIONS. Quantitative angiographic analysis of a matched group of 106 successfully treated coronary lesions showed a similar immediate outcome but reduced long-term efficacy of excimer laser-assisted balloon angioplasty compared with that after balloon angioplasty alone.





HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1995 by the American College of Cardiology Foundation.